==== Front PLoS One PLoS One plos plosone PLoS ONE 1932-6203 Public Library of Science San Francisco, CA USA 10.1371/journal.pone.0243840 PONE-D-20-16165 Research Article Biology and Life Sciences Psychology Behavior Imitation Social Sciences Psychology Behavior Imitation Biology and Life Sciences Bioengineering Biotechnology Biomimetics Engineering and Technology Bioengineering Biotechnology Biomimetics Biology and Life Sciences Cell Biology Cellular Types Animal Cells Stem Cells Stem Cell Niche Biology and Life Sciences Toxicology Cytotoxicity Assay Medicine and Health Sciences Pathology and Laboratory Medicine Toxicology Cytotoxicity Assay Physical Sciences Physics Classical Mechanics Continuum Mechanics Fluid Mechanics Fluid Dynamics Fluid Flow Physical Sciences Materials Science Materials Amorphous Solids Gels Physical Sciences Materials Science Materials Mixtures Gels Biology and Life Sciences Biochemistry Proteins Collagens Biology and Life Sciences Cell Biology Cellular Structures and Organelles Extracellular Matrix Microfluidics and organ-on-a-chip technologies: A systematic review of the methods used to mimic bone marrow A systematic review of bone marrow mimicking methodsSantos Rosalem Gabriel Data curationFormal analysisInvestigationVisualizationWriting – original draft1 Gonzáles Torres Libardo Andrés Data curationFormal analysisInvestigationWriting – review & editing2 de Las Casas Estevam Barbosa ResourcesWriting – review & editing3 Mathias Fernando Augusto Siqueira Data curationFormal analysisWriting – review & editing4 Ruiz Jeronimo Conceição ConceptualizationFormal analysisFunding acquisitionMethodologyProject administrationResourcesSupervisionValidationVisualizationWriting – review & editing45‡* https://orcid.org/0000-0002-0806-2033Carvalho Maria Gabriela Reis ConceptualizationFormal analysisFunding acquisitionMethodologyProject administrationResourcesSupervisionValidationVisualizationWriting – review & editing4‡* 1 Mechanical Engineering Graduate Program, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil 2 Institute of Science and Technology, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, Brazil 3 Department of Structural Engineering, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil 4 Biosystems and Genomics Group, René Rachou Institute, Oswaldo Cruz Foundation, Belo Horizonte, Brazil 5 Graduate Program in Computational and Systems Biology of the Institute Oswaldo Cruz (PGBCS/IOC/Fiocruz), Rio de Janeiro, Brazil Polini Alessandro Editor CNR NANOTEC - Istituto di Nanotecnologia del CNR, ITALY Competing Interests: The authors have declared that no competing interests exist ‡ These are joint senior authors and contributed equally to this work. * E-mail: maria.gabriela@minas.fiocruz.br (MGRC); jeronimo@minas.fiocruz.br (JCR) 11 12 2020 2020 15 12 e024384028 5 2020 29 11 2020 © 2020 Santos Rosalem et al2020Santos Rosalem et alThis is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Bone marrow (BM) is an organ responsible for crucial processes in living organs, e. g., hematopoiesis. In recent years, Organ-on-a-Chip (OoC) devices have been used to satisfy the need for in vitro systems that better mimic the phenomena occurring in the BM microenvironment. Given the growing interest in these systems and the diversity of developed devices, an integrative systematic literature review is required. We have performed this review, following the PRISMA method aiming to identify the main characteristics and assess the effectiveness of the devices that were developed to represent the BM. A search was performed in the Scopus, PubMed, Web of Science and Science Direct databases using the keywords ((“bone marrow” OR “hematopoietic stem cells” OR “haematopoietic stem cells”) AND (“organ in a” OR “lab on a chip” OR “microfluidic” OR “microfluidic*” OR (“bioreactor” AND “microfluidic*”))). Original research articles published between 2009 and 2020 were included in the review, giving a total of 21 papers. The analysis of these papers showed that their main purpose was to study BM cells biology, mimic BM niches, model pathological BM, and run drug assays. Regarding the fabrication protocols, we have observed that polydimethylsiloxane (PDMS) material and soft lithography method were the most commonly used. To reproduce the microenvironment of BM, most devices used the type I collagen and alginate. Peristaltic and syringe pumps were mostly used for device perfusion. Regarding the advantages compared to conventional methods, there were identified three groups of OoC devices: perfused 3D BM; co-cultured 3D BM; and perfused co-cultured 3D BM. Cellular behavior and mimicking their processes and responses were the mostly commonly studied parameters. The results have demonstrated the effectiveness of OoC devices for research purposes compared to conventional cell cultures. Furthermore, the devices have a wide range of applicability and the potential to be explored. http://dx.doi.org/10.13039/501100006507Fundação Oswaldo CruzVPPIS-001-FIO-18-8https://orcid.org/0000-0002-0806-2033Carvalho Maria Gabriela Reis http://dx.doi.org/10.13039/501100006507Fundação Oswaldo CruzVPPIS-001-FIO-18-12Ruiz Jeronimo Conceição Brazilian National Council for Scientific and Technological Development310104/2018-1Ruiz Jeronimo Conceição http://dx.doi.org/10.13039/501100002322Coordenação de Aperfeiçoamento de Pessoal de Nível Superior88882.381160/2019-01)Santos Rosalem Gabriel This work was supported by Fundação Oswaldo Cruz, VPPIS-001-FIO-18-8, MGRC; Fundação Oswaldo Cruz, VPPIS-001-FIO-18-12, JCR; Brazilian National Council for Scientific and Technological Development, 310104/2018-1, JCR; and Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, 88882.381160/2019-01, GSR. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Data AvailabilityAll relevant data are within the manuscript and its Supporting Information files.Data Availability All relevant data are within the manuscript and its Supporting Information files. ==== Body Introduction BM is responsible for producing blood, bone, and immune system cells in a process known as hematopoiesis [1]. BM is located in trabecular cavities of bones and comprises several cell types, such as hematopoietic stem cells (HSCs), mesenchymal stem cells (MSCs), osteoblasts, and other niche cells [2], and also the heterogeneous extracellular matrix (ECM) and an intricate network of blood vessels. ECM of BM provides a mechanical microstructure and a suitable biochemical framework for growth, differentiation, and maintenance of cell functions [3]. The microvascular system of BM is formed by arterial and sinusoidal vessels [4] that perform essential functions such as the delivery of nutrients, cell traffic, and waste removal [5]. BM is composed of three regions called niches: endosteal, central, and perivascular niche. Niches are local tissue microenvironments that maintain and regulate stem cells and are characterized by different physical properties, proteins, and cell types [6]. The endosteal niche contains type I and IV collagen, osteopontin, and fibronectin; it is home for osteoblasts and osteoclasts and its typical stiffness ranges from 35 to 40 kPa [7–9]. The central niche is the least stiff region of BM, with stiffness of approximately 0.3 kPa. It contains laminin, fibronectin, heparin, hyaluronic acid, adipocytes, macrophages, and fibroblasts [10–12]. The perivascular region, in turn, contains type IV collagen, fibronectin, and laminin. The cells that inhabit this niche include endothelial, stromal cells, and MSCs; the stiffness of this tissue varies from 2 to 10 kPa [8, 13, 14]. Another important characteristic of the niches is the distribution of oxygen in the BM microenvironment. The oxygen concentration controls essential cellular processes for the maintenance of the physiological behavior of tissues and organs and is considered a key parameter in the regulation of the survival and quiescence of HSCs in the BM niches [15]. The oxygen concentration is not distributed evenly in the microenvironment of the niches: it is lower in the endosteal niche and gradually increases towards the perivascular niche [16] because of proximity of blood vessels that provide oxygen supply. Understanding physiological and pathological processes associated with BM and its response to different therapeutic strategies is a complex task that requires studying the influence of physical, mechanical, biochemical, and biological characteristics of the cellular microenvironment on the behavior of cells and tissues [17]. The behavior of cells and the influence of different stimuli on living cells and tissues have been attracting the attention of researchers for more than a century already. One of the first approaches that the scientists used in this field were two-dimensional cell cultures [18] and animal models [19]. Though widely used, the 2D cell culture system gives a poor representation of cellular microenvironment, and the resulting in vitro experiments do not reflect the phenomena occurring in vivo [20]. While giving a better representation of cell microenvironment in the human body than the 2D cell cultures, animal models also have some drawbacks, including genetic differences between animals and humans, differences in the cell microenvironment compared to humans, and ethical issues related to animal experiments [21]. An alternative to these approaches that emerged in the last decades is the use of cultures in three-dimensional (3D) environments. These systems allow growing cells in a more realistic environment than their 2D counterpart, hence improving the phenotypic representations cell functions and providing a possibility of reducing the use of animal testing [22]. However, even with the great advancement of 3D culture models, they still cannot mimic some fundamental features of organs, e. g., tissue-tissue interactions, biochemical gradients, and mechanical forces acting in the cellular microenvironment [23]. These limitations directly affect the obtained results that tend to be oversimplified. The oversimplified results, in turn, hinder the understanding of disease evolution in humans and the development of more effective therapeutic strategies [24]. Under these circumstances, devices called Organ-on-a-chip (OoC) provide a promising alternative for studying cellular behavior in a more realistic environment. OoC can be defined as microengineered biomimetic systems [25] designed to study physiological organ- or tissue-specific cell behavior in microfluidic chambers [26]. Microfluidic devices are miniaturized systems, with channels ranging from 10 to 1000 micrometers in size, allowing the flow of small (between 10−9 and 10−18 liters) amounts of fluid [27]. These devices can mimic the micro-architecture, cell environment, signaling and mechanical, physical, and biochemical characteristics of a living organ [28]. One of the important advantages of these systems is that they take into account the fluid flow intrinsic to living organisms. The production of OoC involves specific micro- and nano- fabrication techniques, including replica modeling [20], microcontact printing [29], soft lithography [30, 31], 3D printing [32] and injection molding [33, 34] and the selection of suitable materials for each application. Examples of these materials are polydimethylsiloxane (PDMS), polycarbonate (PC), polymethylmethacrylate (PMMA), polystyrene (PS), polyimide (PI), and polyvinyl chloride (PVC) [35]. Numerous advantages have been reported for the use of OoC, including the flexibility of device design, high level of control of the system parameters, diversity of experimental applications, few required cells, possibility to handle a single cell, real-time analysis using microscopy, possibility to use a coupled analysis system, availability of systems for controlled co-cultures with fluid perfusion, and the reduction of reagent consumption [36]. Some biological advantages include greater accuracy in simulating drug delivery using biomimetic 3D structures [37], the possibility of studying interactions between different cells by controlling factors (nutrients and growth factors) and ECM properties in OoC [38], and control of mechanical signaling induced by tissue deformation and physiological flow [17, 26]. Compared to conventional models, OoC allows a better representation of cell and tissue characteristics not only for fundamental biological research but also for clinical diagnostics and treatment [39]. Currently, there are available several studies in the literature focusing on the development of devices mimicking different organs and tissues (lung [40], kidney [41], gut [42], heart [43], blood vessels [44], spleen [45], liver [46], and brain [47]). There is also a growing interest in mimicking BM: several OoC devices representing physiological and pathophysiological conditions and assessing therapeutic strategies for common diseases like leukemia have been developed over the last years. Considering the critical role of the BM system in the states of health or disease, its biological complexity, diverse functions in the human body, and pathologies that affect it, a growing scientific interest in mimicry of BM’s functions and niches using OoC devices, and a wide range of available materials and production methods for OoCs, the present review aims to identify the state-of-the-art of OoC devices for BM representation. This paper seeks to address the following guideline questions: Which are the main purposes and objectives of using OoC to mimic BM in biological research? Which fabrication processes and materials are used for the devices? Which mechanisms are used for the perfusion? Which materials are used to mimic the BM ECM? Which cell types are commonly used in studies mimicking the BM microenvironment? Which methods and processes are used to evaluate the efficiency of OoC devices mimicking BM? And Are the existing devices effective? Methods To achieve the objective of the study, we have performed an integrative systematic review following the PRISMA–Preferred Reporting Items for Systematic Reviews and Meta-Analyses–method [48, 49]. The first step in the preparation of the review was outlining the guiding questions about the subject. Then, the search strategy (the choice of databases) and the eligibility criteria (inclusion and exclusion criteria) were defined. The final step was to retrieve and summarize the data, results, and conclusions from the selected studies. Articles published in English between January 1st, 2009 and July 24th, 2020, were included in the review. We chose Scopus, PubMed, Web of Science, and ScienceDirect databases, as they cover the fields of engineering, physics, chemistry, and biology, and searched for combinations of the following key expressions in the title, abstract, or keywords of the articles: (("bone marrow" OR "hematopoietic stem cells" OR "haematopoietic stem cells") AND ("organ on a chip" OR "lab on a chip" OR "microfluidics" OR "microfluidic*" OR (“bioreactor” AND “microfluidic*"))). Only original research publications that had an abstract and presented experimental studies on BM mimicking with microfluidic technology (e.g., organ-on-a-chip and lab-on-a-chip) and the applications of these studies, reported qualitative and quantitative results, and referred to human or animal cells were included. Publications with only computational approaches, as well as reviews were excluded. A three-step analysis protocol was followed in the screening process. In the first step, we screened the title and abstract of the publications. Publications that did not contain the words "microfluidic" or "chip" combined with "marrow", "hematopoietic", and "haematopoietic" were excluded in the first round (as works “not containing a microfluidic/OoC approach”). After that, the publications that did not report results or did not refer to BM were also excluded (as works with “irrelevant outcomes”). In the last step, the introduction, results, discussion, and conclusions of the selected publications were systematically screened. Publications that did not mimic at least one BM feature (e.g., specific niches, cell niche interactions, or BM microenvironment) or that assessed only isolated BM phenomena, without associating them with the structural aspects of the BM (e. g., hematopoietic stem cells differentiation in a planar substrate), were also excluded (as works with “poor mimicking”). After that, all remaining publications were selected for qualitative analysis. For the purpose of the analysis, we created a matrix with information related to the most relevant aspects of OoC devices, including physical and biological characteristics, materials and fabrication processes, main phenomena studied and analyses used to validate the efficiency of OoC technology. Results and discussion The number of articles retrieved from all databases was 721, of which, 272 were obtained from Scopus, 218 from PubMed, 205 from Web of Science, and 179 from ScienceDirect database. Before applying the exclusion criteria, we identified and removed duplicate publications (n = 357). Then, the publications classified as ‘not containing microfluidic/OoC approach’ and having ‘irrelevant outcomes’ were excluded (n = 281). After that, we screened the introduction, results, discussion, and conclusions sections of the articles and excluded the publications classified as ‘poor mimicking’ (n = 62). The detailed list of all excluded publications and the reasons for exclusion are given in S1 Appendix in Supporting Information section. After all screening procedures, the remaining 21 articles were included in this systematic review (Fig 1). 10.1371/journal.pone.0243840.g001Fig 1 PRISMA flow diagram. Systematic review of bone marrow mimicking methods. We have organized the data to highlight the results that are most relevant to the state-of-the-art of the investigated question and have classified the publications from the perspective of two main aspects: the device’s features (application of the device, research goals, materials used, fabrication methods, fluidic mechanisms, microenvironment materials, and cell types) and the device performance (methods of assessment and control and improvements that the device offers compared to other research methods). The publications are chronologically organized in Table 1. 10.1371/journal.pone.0243840.t001Table 1 General parameters and improvements provided by the microfluidic approach to BM mimicking. Reference Device application/Research goals Device material/Fabrication method Fluidic mechanism Cells type/Microenvironment material Control/Evaluation methods Main advantages and improvements provided by the device Sung et al., Lab Chip 2009 [50] Modeling pathological BMb Silicon/Conventional photo-lithography Peristaltic pump h-abnormal myeloblastic cell (AML)/Alginate Static 2D culture/Methods: Cell viability; Cytotoxicity assay Perfused 3D hydrogel matrix Drug assayc Provides a more realistic microenvironment compared to conventional culture, improving the understanding of the metabolism-dependent toxicity of an anti-cancer drug Mimicking the pharmacokinetic profile of a drug in the human body Carrion et al., Biotechnol Bioeng 2010 [51] BMC biologya/BM niche mimickingd PDMS/Soft-lithography Reservoir h-UVEC; h-fibroblast; h-MSC/Fibrinogen No control culture/Methods: Analysis of vasculogenesis; Cell migration; Cell adhesion Co-culture in 3D hydrogel matrix Provides a microenvironment able to improve the vasculogenesis and successfully shows the perivascular behavior of MSCs ex vivo Studying the molecular regulation of perivascular stem cell niches in a 3D device Sung et al., Lab chip 2010 [52] Modeling pathological BM PDMS/Soft-lithography Gravity-induced flow h-abnormal myeloblastic cell (AML)/Alginate Static 2D culture/Methods: Cell viability; Cytotoxicity assay Perfused 3D hydrogel matrix Drug assay Provides a more realistic microenvironment, improving the understanding of the metabolism-dependent toxicity of an anti-cancer drug compared to conventional culture Mimicking the pharmacokinetic-pharmacodynamic profile of a drug in multi-organs Silicone/Engineered layer Zhang et al., Tissue Eng–Part C Methods 2014 [53] Modeling pathological BM/BM niche mimicking PDMS/Soft-lithography Syringe pump h-OSB; h-plasma cell myeloma (MM)/OSB-generated No control culture/Methods: Cell proliferation; Cell-tissue interactions Co-culture in perfused 3D OSB-generated matrix Provides a microenvironment based on the perfused culture of MM in ECM OSB-generated capable of improving the mimic of MM-endosteal niche interactions, assisting in the development of novel therapeutics to abrogate microenvironment-driven drug resistance Development of a microfluidic 3D system for preserving the bone marrow-MMC interactions Khin et al., Cancer Res 2014 [54] Modeling pathological BM Plastice/Injection molding Reservoir h-plasma cell myeloma (MM); h-MSC/Type I collagen Static 3D culture/Methods: Pharmacodynamic assay; Chemotherapeutic assay; Cell viability Co-culture in 3D hydrogel matrix Drug assay Provides a microenvironment that improves the understanding of the dynamics of interactions between tumor and stroma in response to therapeutic agents in vitro Studying drug response in MM through an interdisciplinary platform that mimics the 3D microenvironment of BM Torisawa et al., Nat Methods 2014 [55] BMC biology PDMS/Soft-lithography Syringe pump a-BMC/Type I collagen No control culture/Methods: Histological analysis; Cytokines assay; Cell viability Co-culture in perfused 3D hydrogel/bone powder matrix Drug assay Demineralized bone powder Cultivating living marrow with a functional hematopoietic niche in vitro Provides a biomimetic microphysiological system improve the prediction of the in vivo response of hematopoietic niche to clinically cues, whereas conventional cell cultures do not Thon et al., Blood 2014 [56] BMC biology PDMS/Soft-lithography Syringe pump a- and h-MK/Alginate; Matrigel Static 3D culture/Methods: Cell morphology; Cell differentiation Co-culture-perfused 3D hydrogel matrix Development of a scalable, human-induced pluripotent stem cell-derived MK-compatible PLT microbioreactor Provides a physiological BM environment in vitro as in vivo, improving platelet production compared to conventional cultures h-UVEC/Fibronectin-coated surface Bruce et al., PLoS One 2015 [57] Modeling pathological BM PDMS/Soft-lithography Syringe pump h-abnormal lymphoblastic cell (ALL); h-MSC; h-OSB/Type I collagen Static 2D culture Co-culture in perfused 3D hydrogel matrix Drug assay Static 3D culture/Methods: Chemotherapeutic assay; Cell-tissue interaction; Cell viability Provides characteristics in vitro based on BM physiology and structure in vivo, improving the investigation of the effects of cell-cell and cell-matrix interactions on the initiation and progression of cancer compared to static 2D and 3D culture Development of a 3-D microfluidic triculture model in a biomimetic manner Zhang et al., PLoS One 2015 [58] Modeling pathological BM/BM niche mimicking PDMS/Soft-lithography Syringe pump h-OSB; h-plasma cell myeloma (MM)/OSB-generated Static 3D culture/Methods: Cell viability; Cell proliferation; Biochemical analysis Co-culture in perfused 3D OSB-generated matrix The 3D microfluidic provides a microenvironment based on the perfused culture of MM in ECM OSB-generated capable of improving the mimic of MM-endosteal niche interactions, replicating the multicellular MM tumor niche with perfusion as an important microenvironmental factor and improving the maintenance of long-term co-culture Development of a 3D device for MM-bone marrow stromal cells long-term co-culture Wuchter et al., Cell Tissue Res 2016 [59] BMC biology PC; PMMA; COC/Injection molding; hot embossing Cassette pump h-HPC; h-MSC/Type I collagen-coated surface Dynamic 2D culture/Methods: Phenotypes analysis; Cell differentiation; Co-culture in perfused 3D MSC-generated matrix Development of a microfluidic 3D model system of the human hematopoietic stem cell niche Provides an environment able to creating a more physiological environment for HSPC when compared to 2D co-culture, preserving its stem cell properties and improving the maintenance of stem cell culture for longer Torisawa et al., Tissue Eng–Part C Methods 2016 [60] BMC biology PDMS/Soft-lithography Syringe pump a-BMC/Type I collagen Static 2D culture/Methods: Phenotype analysis; Cell viability; Radiation exposure; Co-culture in perfused 3D hydrogel/bone powder matrix Drug assay Demineralized bone powder Cultivating living marrow with a functional hematopoietic niche in vitro Provides a bone marrow-based 3D model able to mimic the hematopoietic niche and the cell behavior as in vivo, including the improvement of the hematopoietic process such as hematopoiesis and the responses to drugs and radiation compared to conventional cultures Miller et al., Biotechnol Bioeng 2016 [61] BMC biology Silicone; PMMA; PC/Laser cutting; Milling Gravity-induced flow h-abnormal megakaryoblastic cell (CML)/PGMatrix hydrogel Static 2D culture/Methods: Cell viability; Perfused 3D hydrogel matrix Describing the design and operation of a 14 chamber multi-organ system Provides a microphysiological system capable of mimicking cellular behavior as in vivo, improving the maintenance of viability in vitro compared to conventional cultures Zheng et al., Adv Heal Mater 2016 [62] Modeling pathological BM PDMS/Soft-lithography Reservoir h-UVEC; h-abnormal promyeloblastic cell (APL); abnormal bone marrow cells (CML, HL)/h-Stromal marrow cell/Type I collagen No control culture/Methods: Cell motility; Angiogenesis analysis Co-culture in 3D hydrogel matrix Using a 3D biomimetic model to study leukemic cell-induced bone marrow angiogenesis Provides a microengineered 3D microenvironment able to promote the angiogenesis induced by different types of leukemic cells Houshmand et al., Tissue Eng–Part C 2017 [63] Modeling pathological BM PDMS/Soft-lithography Peristaltic pump h-abnormal erythroblast cell (ERY); h-MSC/Demineralized bone matrix Static 2D culture/Methods: Phenotype analysis; Cell proliferation; Cell morphology; Chemotherapeutic assay; Cytotoxicity assay Co-culture in perfused 3D scaffold Drug assay Provides a 3D mimicked AML microenvironment capable of studying the effect of stromal cells and bone marrow niche on the viability of leukemic cells, improving cellular proliferation when compared to conventional cultures and predicting their response to drugs as in vivo Designing of a perfusioned 3-D microenvironment to mimic the acute myeloid leukemia for molecular study and drug screening Type I collagen Sieber et al., J Tissue Eng Regen Med 2018 [64] BMC biology PDMS/Soft-lithography Peristaltic pump h-MSC; h-HSPC/3D hydroxyapatite ceramic Static 2D culture/Methods: Cell differentiation; Phenotype analysis; Gene expression analysis Co-culture in perfused 3D scaffold Generation of a versatile, bone in vitro culture system mimicking the human bone marrow and niche biology The BM-on-a-chip that integrates a 3D structure, and a physiological flow provides a model of BM niche environment capable of long-term culture of HSPC, improving the cell behavior in vivo when compared to conventional methods Kotha et al., Stem Cell Res Ther 2018 [65] BMC biology/BM niche mimicking Type I collagen/Injection molding Gravity-induced flow h-Stromal marrow cell; h-MSC /Type I collagen No control culture/Methods: Cell migration; Cell adhesion; Phenotypes analysis; Cell-cell interaction; Gene expression Co-culture in perfused 3D hydrogel matrix Development of an engineered human vascular marrow niche Provides a microenvironment able to study the mechanisms behind dynamic spatial and temporal cell-cell interactions within the vascular niche in both healthy and disease-remodeled marrow spaces, improving the understating about hematopoietic cell adhesion, transmigration, and engraftment h-UVEC; h-monocytes; h-HSPC; abnormal bone marrow cells (AML) Marturano-Kruik et al., Proc Natl Acad Sci U S A 2018 [66] BMC biology/BM niche mimicking PDMS/Soft-lithography Syringe pump h-MSC; h-UVEC/Decellularized bone scaffold Static 2D culture Co-culture in perfused 3D scaffold Mimicking the human bone perivascular niche Dynamic 3D culture/Methods: Vasculogenesis assay; Histological analysis; Gene expression; Chemotherapeutic assay Provides a 3D environment capable of mimicking the native structure and surface properties of bone marrow, interstitial flow, controlling the transport of nutrients, metabolites, and oxygen, improving the angiogenic processes in an in vitro model Aleman et al., Small 2019 [67] Modeling pathological BM PDMS/Soft-lithography Peristaltic pump h-BMNC/HA gelatin No control culture/Methods: Cell viability; Phenotype analysis; Cell quantification Co-culture in perfused 3D hydrogel matrix BMC biology h-HSPC; h- abnormal bone marrow cells (HL, AML); Provides a biomimetic physiologic environment, improving the study of the interactions of distinctive HSPC with different niches, under conditions of both health and disease Development of a human BM niche-on-a-chip (NOC) platform with an integrated recirculating perfusion system McAleer et al., Sci Transl Med 2019 [68] Modeling pathological BM PMMA; PDMS/Laser-cut Gravity-induced flow h-abnormal myeloblastic cell (AML); h-abnormal megakaryoblastic cell (CML)/Alginate No control culture/Methods: Cell viability; Cell density; Enzymatic assay; Chemotherapeutic assay; Cell proliferation; Cell quantification Co-culture in perfused 3D hydrogel matrix BMC biology Provides a mimetic system able to investigate anticancer drug efficacy and off-target effects, improving the response of the cell and effectively demonstrating the effects on cancer cells observed clinically Drug assay Mimicking the multi-organ system Herland et al., Nat Biomed Eng 2020 [69] BMC biology PDMS/Soft-lithography Peristaltic pump h-UVEC/Type I collagen- and fibronectin-coated surface No control culture/Methods: Phenotype analysis; Cell quantification Co-culture in perfused 3D hydrogel matrix Drug assay Provides a mimetic human system in vitro suitable for drug discovery, regulatory assessment, toxicological evaluation, and personalized medicine, improving the therapeutic development by enabling the more effective design of drug regimens for future phase-I clinical trials Designing of a first-pass model of human drug absorption, metabolism and excretion h-HSPC/Type I collagen fibronectin Chou et al., Nat Biomed Eng 2020 [70] BMC biology PDMS/Soft-lithography Peristaltic pump h-HSPC; h-HSPC abnormal (SDS); h-MSC/Type I collagen Static 2D culture Co-culture in perfused 3D hydrogel matrix Modeling pathological BM Static 3D culture /Methods: Cell proliferation; Cell differentiation; Cytotoxicity assay; Chemotherapeutic assay; Radiation exposure; Phenotype analysis Provides an in vitro biomimetic model of vascularized human BM that improve the maintenance, proliferation, and cellular functions, enabling the recapitulation of many clinically relevant features of BM pathophysiology in response to clinically relevant exposures to drugs and radiation Drug assay Development of a vascularized human BM-on-a-chip Fibrinogen h-UVEC/Type I collagen- and fibronectin-coated surface aBMC biology; General descriptor for clustering publications that aim to mimic the BM environment without distinction of niches and/or represent the processes and phenomena associated with BM cells such as proliferation, differentiation, migration, hematopoiesis, et cetera bModeling pathological BM; General descriptor for clustering publications that aim to mimic the abnormal cell behavior in BM microenvironment in vitro cDrug assay; General descriptor for clustering publications that report the cell's response to drugs, radiation, chemotherapeutics, et cetera dBM niche mimicking; General descriptor for clustering publications that aim to mimic specific niches in vitro considering their physiology and architecture eThe material has not been identified BMC, bone marrow cells; prefix h-, human cells; prefix a-, animal cells; MM, multiple myeloma; AML, acute myeloid leukemia; ALL, acute lymphoblastic leukemia; CML, chronic myelogenous leukemia; APL, acute promyelocytic leukemia; HL, histiocyte lymphoma; ERY, erythroleukemia; SDS, Schwachman–Diamond syndrome; UVEC, umbilical vein endothelial cells; MSC, mesenchymal stem cells; OSB, osteoblasts; MK, megakaryocytes; HPC, hematopoietic progenitor cells; HSPC, hematopoietic stem progenitor cells; BMNC, bone marrow mononuclear cells; HA, hyaluronic acid OoC applications One of the objectives of this review was to identify the main applications of the BM mimicking devices reported in the literature. Four broad categories of applications have been identified: a) BMC biology [51, 55, 56, 59–61, 64–70], defined as a descriptor for classifying publications that aim to mimic the healthy BM environment without distinction of niches and/or represent the processes and phenomena associated with BM cells such as proliferation, differentiation, migration, and hematopoiesis. In this group, the main cells regulating BM functions were considered, including mesenchymal stem cells, hematopoietic stem progenitor cells and osteoblasts; b) Modeling pathological BM [50, 52–54, 57, 58, 62, 63, 67, 68, 70], defined as a descriptor to classify publications that aim to mimic the pathological microenvironment and the behavior of abnormal cells in a BM-on-a-chip; c) Drug testing assay [50, 52, 54, 55, 57, 60, 63, 68–70], defined as a descriptor to classify publications that report the cell's response to drugs, radiation, chemotherapy and other stimuli; and d) BM niche mimicking [51, 53, 58, 65, 66], defined as a descriptor to classify publications that aim to mimic specific niches in vitro taking into account their physiology and architecture. As the variety of applications suggests, these devices have a broad of spectrum of uses. Though studying healthy BM cells and microenvironment is the main focus of most of the articles selected for the systematic review, the large number of publications addressing the abnormal BM microenvironment indicates that the study of BM-affecting pathologies is another emerging biomedical application for OoC devices. We have identified the publications that assessed multiple myeloma (MM) [53, 54, 58], acute lymphoblastic leukemia (ALL) [57], acute myeloid leukemia (AML) [50, 52, 67, 68], chronic myeloid leukemia (CML) [61, 62, 68], and other cells. The common goal of these publications was contributing to the understanding of the physiopathology of BM diseases and investigation of new treatment protocols for people with these diseases. From the physiological point of view, one of the important aspects of BM structure are the niches: the regions with distinctive properties and cell types [6] working in an integrated manner to ensure the function of niche cells. Regarding the category ‘BM niche mimicking’, it should be noted that only five of the selected publications considered the BM niches and none of the proposed devices addressed all the three niches. The great majority of the devices represented specific regions of BM, e.g., close to the endosteum (endosteal niche) [53, 58] or around the blood vessels (perivascular niche) [51, 65, 66]. The development of devices that mimic only one region of the BM is most likely related to the difficulties in representing the distinct physical, chemical, and biological characteristics of BM [71]. Nevertheless, mimicking individual niches can help to understand the processes governed by the specific characteristics of the given regions and explain some aspects of the cellular behavior in the BM environment. From this perspective, it should be noted that two papers included in the review assess the influence of the endosteal niche on the response of abnormal cells [53, 58] and one assesses the behavior of BM cells in a 3D environment with an oxygen gradient, and mimics the perivascular niche [66]. On the other hand, mimicking only a given region certainly affects the obtained information since in this case, the devices cannot represent various interactions that exist between BM niches. It is interesting to note that the developed devices mimicking BM in some cases, are part of a more complex system. Five of the selected publications [50, 52, 61, 68, 69] concern the devices that in one way or another attempt mimicking BM as a part of a microphysiological model of the human body; the devices built for this purpose are known as the body-on-a-chip or multi-organ system devices. Material and fabrication techniques The development of OoC devices involves several challenges associated with their fabrication, including the costs and time required, the geometry and size of the channels, and surface properties. The selection of suitable materials and fabrication techniques is one of the most important steps in the development of OoC devices. Fabrication materials The selection of the most appropriate materials for each application of OoC depends on some factors that shall be taken into account in BM mimicking devices. The first one concerns the biocompatibility of materials, needed to guarantee an adequate cellular response in a specific application [72]. The second one is the maintenance of the long-term culture, which is vital in the studies of hematopoietic processes [73] and biological processes associated with mesenchymal cells (e. g. differentiation and ECM secretion). Next factor is gas exchange governed by permeability. Standard cell cultures require stable and well-defined O2 and CO2 concentrations; any variations in these parameters can be harmful to the cells. One more factor concerns chemical products that may form at the interface pharmaceutical product/material. These chemical products can be converted into signals that influence the cellular response to a given clinical treatment [74]. This is important, for instance, when BM chips are used in drug testing. And one more factor is related to the optical properties of the material. The imaging techniques that are usually used for data collection (e.g., fluorescence microscopy, confocal microscopy, phase-contrast microscopy) require the use of transparent OoC devices that can be monitored without disassembling. The present review showed that PDMS, PMMA, silicon, PC, and silicone were the main materials used to create BM channels in OoC devices. Polymeric materials were used more often, suggesting that they have the properties required for in BM mimicking OoC devices [75]. Compared to brittle glass and silicon materials that require non-trivial sealing protocols, thus making the fabrication process expensive and complex, polymers offer cost-effective manufacturing and allow creating high- quality low-cost products. The review has shown that PDMS was the most commonly used polymer material for the construction of BM channels in OoC devices. PDMS is a biocompatible material that can be sterilized in an autoclave and is easy to use in microengineering, explaining its widespread use in the production of OoC devices [76]. Furthermore, PDMS has remarkable elasticity, low production costs [77, 78], and high oxygen permeability, which allows using it for long-term cultures. The translucency of the material facilitates the use of imaging technologies, e.g., confocal and fluorescence microscopy for the biological characterization of the environment [79]. In the articles that were analyzed in this review, PDMS was used in several applications for in vitro mimicking of BM, including a) assessment of normal and abnormal behavior of BM cells in drug presence [50, 52, 54, 55, 57, 60, 63, 68–70], and b) creation of long-term cultures (more than 20 days) [53, 58, 64, 69, 70]. At the same time, even though it is the first-choice material in the analyzed articles, some characteristics of the PDMS are disadvantageous for its use in BM mimicking OoC devices. For example a) the absorption of the medium culture and drug components; b) formation of bubbles; and c) distortion of the device’s geometry [77, 80]. Recently, efforts have been made to identify and test new materials able to replace or modify the PDMS for use in BM OoC devices [81–85]. To overcome the disadvantages mentioned above some authors proposed the use of coating methods and design adequation [84, 85]. Among the alternative materials identified in this systematic review, PMMA appears to be a good option and is cited in three publications. PMMA is the acrylate-family polymer known for fracture resistance, translucency, and elasticity [86], as well as high chemical resistance [87]. In addition, PMMA is a low-cost and easily manufactured material [88]; it is also less hydrophobic than PDMS or other polymers used in microfluidic devices, thus ensuring a lower absorption of hydrophobic molecules crucial characteristics for the preservation of cell culture. Fabrication techniques The choice of fabrication methods is based on material properties. For the devices made of PDMS as the main material, the conventional soft-lithography was used [51–53, 55–58, 60, 62–64, 66, 67, 69, 70]. Soft-lithography is a technique based on conventional photolithography for fabrication or replication of structures made of elastomers. It is generally used to produce micro- and nanostructures [78, 89] and its low cost and versatility makes it the most common technique in the fabrication of microfluidics devices, since it allows building different planar and non-planar surfaces and 2D and 3D structures with a resolution of up to 30 nm and a minimum size of 10 to 100 nm [90, 91]. The main drawback of this technique is that it is time-consuming and requires highly trained and specialized personnel for the operation of the equipment [52]. Besides soft-lithography, two other fabrication techniques were used a) laser cutting [61, 68]; and b) injection molding [54, 59, 65]. Process automation makes the laser cutting and injection molding relatively simpler fabrication methods for the operators compared to soft-lithography. However, fabrication of the master mold is very expensive because of the high pressures and temperatures involved. The most commonly used polymers are the most rigid ones, such as PC and PMMA. Flow mechanisms for device perfusion One of the most important characteristics of OoC systems is that they allow mimicking the cell microenvironment while taking into account the fluid flow in the same way as it is present in living organs, thus expanding the scope of studies and helping to understand the phenomena within this microenvironment. Using a fluid flow allows modelling physiopathological conditions in human organs on a microfluidic device [25, 26]. The stimulation caused by a fluid flow can induce biological cell responses through a mechanism known as mechanotransduction [92]. The mechanical shear stresses generated by the fluid flow also influence several cellular processes, e.g., proliferation and differentiation of human osteoblasts [93], adhesion of leukemic and hematopoietic progenitor cells [94], osteogenic differentiation of MSCs [95, 96], emergence of HSCs via endothelial-to-hematopoietic transition [97], and endothelial cell behavior [98, 99]. Finally, it is important to mention that almost all studies included in the review take the fluid flow into account. Fluid flow and recirculation are essential for a realistic representation of the behavior of cells. In the BM microenvironment, interstitial fluid constantly stimulates the cells and induces cellular proliferation and differentiation [96, 98]; it also supplies the cells with oxygen, nutrients, and growth factors and removes the metabolic products from the cells. Considering the importance of fluid flow in BM cell processes, one of the guideline questions outlined in this review was: Which mechanisms are used for device perfusion? The analysis of the selected papers identified two main mechanisms: a) active flow; and b) passive flow. Active flow mechanisms The syringe and peristaltic pumps were the most used active flow mechanisms in the revised publications. These mechanisms comprise systems containing a pump, a culture medium reservoir, and the connecting pipes between the device and reservoir. There were identified some differences between these systems, e.g., syringe pumps produce unidirectional flow, not allowing fluid recirculation, while peristaltic pumps allow recirculation. Because of the recirculation of the culture medium, peristaltic pumps can better mimic the physiology of the cellular microenvironment and, hence, are more suitable for the studies of the pharmacokinetics and pharmacodynamics of a drug in the human body [50, 100]. Though the pumps are the most used approach for fluid flow induction, they have some disadvantages. One problem related to the use of peristaltic or syringe pumps or tube-connected devices is that these systems can generate the so-called “air bubbles”, which are harmful to cells and must be avoided to maintain the integrity of experiment [52, 101]. As reported in some studies included in this review [50, 66], to overcome this drawback and prevent the bubbles, a “bubble trap” is usually attached to the system. The “bubble traps” require the use of a vacuum system, hydrophobic-coated surfaces, membranes, and pressurized fluids [102]. The “trap” is based on the floating of air bubbles associated with their low density. The bubbles are collected in a compartment that separates them from the fluid, allowing regular flow and preventing the cells from damage [101]. Passive flow mechanism Taking the difficulties presented by active flow mechanisms into account, some studies included in the review used passive flow mechanisms, such as gravity-driven flow [52, 61, 65, 68]. This mechanism involves the use of fluid reservoirs located at different heights. In this case, gravity generates a flow proportional to the elevation and the density of the fluid [100]. This low-cost method prevents the formation of bubbles, is simple in operation, and generates flows with physiological shear stress on the cells [61]. Though having many advantages, the renewal of the culture medium in gravity-generated flow systems can be a problem. This can lead to recirculation of the culture medium with fewer substances and more waste from cell activity, which may lead to cell death and prevents long-term experiments [50]. It is noteworthy that through the development of OoC devices capable of growing cell culture under perfusion of culture medium, several studies were able to generate the dynamic BM microenvironment in vitro. Several in vivo characteristics of the BM were mimicked using different flow generation techniques: cellular stimuli created through physiological shear stress generated by the fluid [56, 58]; regulation of BM physiological parameters through fluid perfusion [55]; in vitro generation of flow within the medulla with physiological interstitial velocities [57, 66]; and creation of a physiological vascular system, including the supply of oxygen and nutrients and the removal of metabolic products [70]. This indicates that perfused cell culture in vitro can generate more realistic environments for cell culture, thus improving understanding of specific phenomena that occur in the BM. Materials and cells for mimicking the BM microenvironment BM is one of the most complex and largest organs in the human body and the main hematopoietic organ, responsible for the production of different cell types, e g., erythrocytes, granulocytes, monocytes, lymphocytes, and platelets [103]. The BM ECM is a non-cellular structure composed of many proteins, such as collagen, laminin, fibronectin, and fibrinogen, which provides essential physical support for tissue integrity, elasticity, and the hematopoiesis process. In addition, BM ECM provides a biochemical environment for cellular growth, differentiation, and maintenance [3, 104, 105]. It is also reported in the literature that cytokines, chemokines, and ECM proteins provide stimuli and interactions for cell homing through specific biochemical signals and regulate some HSCs functions [104, 106]. The main function of BM microenvironment is to maintain homeostasis by providing signals that regulate and support the differentiation of HSCs in the progenitor blood cells and the subsequent proliferation of these differentiated cells, leading to the production of billions of blood cells [107]. A key aspect of understanding how to develop more realistic BM-mimicking devices is the evaluation of material properties and cell types of this microenvironment. Improved BM microenvironment representation is a central issue for in vivo mimicry. One of the most important aspects mentioned in the selected publications was how BM substrate/ECM is represented. Besides that, the cells selected for microenvironment composition and the culture are also extremely important in mimicking the BM. Based on that, the studies mimicking BM can be divided into two categories that include the ECM representation and cell composition representation, respectively. BM microenvironment Based on the different studies included in this review, three models representing the BM were identified: hydrogel/gel; scaffolds; and ECM-secreted (Table 2). 10.1371/journal.pone.0243840.t002Table 2 Materials used for mimicking the bone marrow. Material types and structure Gel model Scaffold model ECM secreted 3D matrix Surface coating Type I collagen [54, 57, 62, 65] Type I collagen [59] • Alginate [50, 52, 56, 68] • Matrigel [56] • Type I collagen/fibrinogen [70] • Type I collagen/fibronectin [69] Type I collagen/fibronectin [69, 70] • PGMatrix [61] • Fibrin [51] • HA Gelatin [67] • Bone powder/type I collagen [55, 60] • Bone matrix/type I collagen [63] • Hydroxyapatite [64] • Decellularized bone [66] • Polystyrene [66] • Ossified tissue [53, 58] • Fibronectin [56] • The first approach used to mimic the BM microenvironment was the hydrogel model. A hydrogel can be defined as a solid lacking a macroporous design [70]. The hydrogel is a polymerizable material that permits forming transparent 3D structures. In the ECM formation, the polymerization process of the 3D network influences the interactions between the cells and the matrix in this microenvironment [108]. That is, the cells interact with the cellular microenvironment similarly to their in vivo counterparts. This interaction influences the cell's phenotype and the factors they secrete in ECM [109]. In addition, the transparency of the material permits obtaining high-resolution images of the culture [62]. Chemical and mechanical properties of hydrogels depend on the type of hydrogel used in cell cultures [110]. Type I collagen, alginate, Matrigel [56], hyaluronic acid [67], fibronectin [69], and fibrin [51] are some of the protein types and ECM components that compose natural hydrogels [8]. The use of natural hydrogels provides a suitable microenvironment for the cultivation of BM cells, keeping their functions similar to those in vivo [57]. However, different production protocols of these components lead to variation in the compositions, making it difficult to predict and standardize the effects of the hydrogel matrix on cell behavior [110]. In the gel/hydrogel models, the most used components mimicking the BM environment were a) type I collagen-based hydrogel [54, 55, 57, 60, 62, 65, 69, 70] and b) alginate-based hydrogel [50, 52, 56, 68] Type I collagen is fibrillar collagen. Probably it is the most studied and abundant collagen type. Its Young’s modulus depends on a density. Different studies have reported the production of 3D collagen structures with Young’s modulus values around 10 Pa (0.5 mg/ml) [111], 300 Pa (2 mg/ml) [111, 112], and 1200 Pa (4 mg/ml) [111]. Type I collagen with different densities can be used to mimic BM niches with different stiffness because its mechanical properties and their control methods are well known. Nevertheless, the low mechanical strength of collagen gels results in their significant contraction caused by the cells, and this is an important drawback of collagen use in systems without geometric constraints [113]. On the other hand, alginate hydrogel Young’s modulus ranges from 100 Pa (relatively elastic) to 10 kPa (moderately stiff) [114, 115] making it more suitable for mimicking the BM because BM Young’s modulus ranges from 0.1 to 1 kPa [1]. For example, in cultures of non-adherent abnormal cells, such as myeloblastic lineage cells, alginate provides a more realistic environment than Matrigel, retaining leukemic cells and improving their response [50]. In addition, when used as an ECM, alginate hydrogel provides greater cell growth compared to standard cell culture protocols [1]. Another way of representing ECM is by structures referred to as scaffolds; the scaffolds can be made of hydroxyapatite, polystyrene, and bony structure (Table 2). Scaffolds are well-defined macroporous 3D structures with properties similar to those found in vivo [116]. Scaffolds are characterized by their geometry, mechanical properties, and composition. The pores, the size, architecture, fabrication methods, and used material govern the properties of the scaffold [117]. In the reviewed publications, the scaffolds were made of synthetic materials [64, 66] or bony structures [63, 66]. Scaffolds can mimic trabecular bone, especially its structural and mechanical properties, allowing, therefore, to represent a spongy bone and BM niches [64]. This permits modelling the endosteal niche located near the trabecular bone that regulates the behavior of human hematopoietic cells [6]. Unlike the hydrogel-formed structure, the use of the scaffolds has some technical drawbacks. The materials commonly used to create scaffolds, such as hydroxyapatite, polypropylene, and polystyrene, may not be transparent [63, 64, 66]. Since a large part of the analysis techniques is based on light microscopy, opacity makes it difficult or impossible to view and record images, affecting the assessment of the device's effectiveness. Finally, in addition to studies pointing out the hydrogel/gel and scaffolds, some studies have used living cells to produce the ECM by cultivating the cells on the surface of the device itself, creating specific niches of BM microenvironment [53, 58]. Using niche cells to generate the microenvironment through the secretion of ECM, growth factors and cytokines produce a matrix with chemical and mechanical properties that maintains the cellular behavior similar to in vivo. For cell cultures on the device surfaces [56, 59, 69, 70], specific coatings were used to mimic the surface properties of the cellular environment of organs and tissues. The coating improves the cell adhesion and generates a phenotypic representation as expected in vivo, ensuring a realistic cell behavior in a given environment [118]. BM cell types and cellular culture A wide variety of cell types was used to constitute the bone marrow microenvironment. Mesenchymal stem cells, osteoblasts, and endothelial cells are some of the reported cell types, in addition to hematopoietic [59, 65, 67, 69, 70] and leukemic cells [50, 52, 57, 61, 62, 65, 67, 68]. Other studied cell types are given in Table 1. The studies have evaluated both co-cultures and single-cell cultures. As BM is a very complex biological organ, it is essential to understand the functioning of its regions to choose the best cell culture approach [6]. The culture of one cell type provides a more manageable environment for in vitro testing, making it possible to analyze the collective behavior of specific cell types under well-defined physiological conditions. However, the in vivo cell environment is composed of several cell types and the cell-cell and cell-ECM interaction are determinant for cellular behavior. For example, cells that are present in the endosteal, central, and perivascular niches play key roles in stem cell behavior, regulating differentiation into red and white blood cells that will migrate into the bloodstream [119, 120]. A simulation of this complex environment in vitro is challenging for researchers, as regions with different mechanical and biological properties need to be reproduced in the same device [3], requiring the adjustment of the culture medium, oxygen supply, fluid flow, and mechanical properties in a complex microfluidic system. Nevertheless, most of the publications in the review use the co-culture approach to represent the cellular microenvironment of BM. This suggests the evolution of technologies and methods of cell culture that allow implementing this model with the in vitro systems. However, some screened publications used single-cell cultures to represent in a simplified way a phenomenon that in reality occurs in a complex BM environment. Though BM environment is a dynamic system governed by cell-cell and cell-ECM interactions, integrating the ECM and cells properties in the OoC devices analyzed in this systematic review allowed detecting various cellular behaviors and phenomena associated with BM: the regulation of HSP and HPC cells in the hematopoietic microenvironment by interaction with niche cells, such as osteoblasts, perivascular endothelial, and perivascular stromal cells [55]; the preservation of MM cells in a 3D ossified tissue constructed by a human osteoblast cell line (endosteal niche) [53, 58]; the effect of chemotherapeutic drugs on abnormal cells in a 3D environment with co-cultivation of BM cells [57, 63]; the hematopoiesis process in a 3D BM model based on collagen hydrogel and bone powder [60]; the long-term culture of HSPC in co-culture with MSC in a 3D scaffold that mimics trabecular bone [64]; the regulation of normal and abnormal HSPC behavior in a 3D multi-niche system [67]; and the mimicking of hematopoiesis processes in a 3D matrix in co-culture with MSC and HUVEC [70]. Effectiveness of current OoC devices mimicking bone marrow Over the years, the understanding of cellular processes and the clinical trial stages for drug development was achieved with the support of conventional cell culture platforms (2D and 3D static). Despite the relative success of this approach, it is important to stress that these platforms represented the cellular microenvironment in a simplified way [121]. It is also important to underline that the ideal in vitro cell culture representation must include two crucial aspects: the physiology and the structure of the cellular microenvironment. This can be achieved by ensuring three basic conditions in the devices: cell culture in a 3D environment, cell co-culture, and cell culture under perfusion. Considering the above-mentioned basic conditions as advances in conventional cell culture methods, the articles included in this systematic review were classified into five groups according to the approach used: perfused 3D hydrogel matrix [50, 52, 61]; co-culture in 3D hydrogel matrix [51, 54, 62]; co-culture in perfused 3D hydrogel matrix [55–57, 60, 65, 67–70]; co-culture in perfused 3D scaffold [63, 64, 66]; and co-culture in perfused 3D cell-generated matrix [53, 58, 59]. To assess the effectiveness of these new design proposals, the studies integrated used control groups based on conventional platforms and a gold standard for evaluating the causal hypothesis: static 2D culture [50, 52, 57, 60, 61, 63, 64, 66, 70]; dynamic 2D culture [59]; static 3D culture [54, 56–58, 70]; and dynamic 3D culture [66]. Seven publications included in this review did not report a control group in their experimental analysis [51, 53, 55, 65, 67–69]. The detailed list of main evaluation technologies and cellular assays are given in S1 Table. The evaluation of the device’s effectiveness was performed taking into account groups that were defined with the three basic conditions described above. In order to better understand the influences of 3D matrix, co-culture, and the fluid flow on the reported results, an incremental evolution analysis was used: the articles were assessed in groups that represent the increase of the complexity of the device compared to the conventional method. These groups were classified as: a) static cultures of multiple cell types; b) perfused cultures of single cell types; and c) perfused cultures of multiple cell types. Static cultures of multiple cell types The first approach, static cultures of multiple cell types, was based in a 3D co-culture in vitro system without the presence of fluid flow. BM mimicking using this approach allowed reproducing the phenomena of vessel formation in the healthy BM [51] or the vessel formation induced by leukemic cell lines [62]. It is known that the presence of blood vessels in BM physiology is vital for the supply of nutrients, oxygen, and growth factors necessary for niche cell survival and regulation of hematopoietic cell behavior [5]. The region where these vessels are located in a healthy BM is called the perivascular region, or perivascular niche of the BM. With an objective to mimic this niche specifically, publications considered endothelial and stromal cells as basic components, since these are the cell types present in the native composition of the perivascular niche of the BM [8]. The simulated behavior of cell migration [51, 62] and adhesion [51], vasculogenesis [51], and angiogenesis [62] of niche cells were reported to be similar to in vivo; in addition, there was also the formation of vessels through the association between multicellular aggregates and fibroblasts sprouting in a primitive capillary plexus as it is detected in the microenvironment of BM. Besides the study of cell behavior around the vascular region, the 3D co-culture approach also provides useful tools for understanding the response of tumor cells to the action of drugs. In a 3D matrix based on type I collagen, an experiment carried out to evaluate the chemotherapeutic effects on plasma cell myeloma reported a reduced action of drugs when the abnormal cells were cultured with bone stromal cells [54], resulting in increased viability (live/dead) of the cells. This phenomenon occurs because of a mechanism known as cell adhesion–mediated drug resistance caused by a) the direct MM–BM stroma cell adhesion; b) by MM-ECM adhesion; or c) by the secretion of a soluble factor [54]. Cell adhesion-mediated drug resistance is related to the increase of drug resistance mediators and avoiding the apoptosis process [122]. Perfused cultures of single cell types Using the second approach, perfused cultures of single cell types, which is based on a perfused 3D system without co-culture, publications reported better results for toxicity response and cellular proliferation than those reported in conventional 2D control groups. Evaluating viability (toxicity and proliferation), myeloblastic cell lines showed greater sensitivity to drug exposure [50, 52] and megakaryoblastic cell lines were maintained in long-term culture [61]. The two previously mentioned approaches showed that a simplified BM mimicking with the in vitro system was able to represent the phenomenon that occurs in vivo. In other words, a system that uses the minimum characteristics essential to mimic a specific phenomenon can replicate it in vitro. The studies that use a 3D co-culture [51, 54, 62] or perfused 3D single-cell culture [50, 52, 61] consider the influences of two specific features of microenvironment on cell’s response, besides the ECM interactions, namely: a) cell-cell interactions; and b) fluid flow action. Cell-cell and cell-ECM interactions play a key role in regulating cell functions and the microenvironment. These interactions occur through the so-called cell junctions and involve mediator proteins including cadherins and integrins that sense and respond to the external signals of the microenvironment [123]. The dynamic flow of the physiological fluid supplies nutrients, oxygen, and growth factors, and removes metabolic products from the cells. In addition, cellular behavior is influenced by flow-generated shear, which promotes a biological response of cells according to the mechanisms involved in cellular mechanotransduction [124, 125]. It is important to point out that the two approaches discussed so far have considered isolating the co-cultured cells in a static system or single-cell culture in a perfused system. Despite the important achievement in obtaining similar biological results as in vivo, the individual evaluation of these mechanisms is a simplified representation of the BM microenvironment and does not consider the dynamics of interactions and stimuli. Perfused cultures of multiple cell types The third group of studies that attempted to overcome these issues and took into account all the three basics conditions for representation of BM environment in vitro was clustered: a 3D environment, formed by the proper matrix; a co-culture with specific bone marrow cell; and a perfused culture medium, as a source of oxygen, nutrients, and shear stress stimulation. In this systematic review, this group of studies was further subcategorized by specific applications and approaches: a) focusing in mimicry specific regions of BM; b) different approaches to BM ECM representation; c) studies of physiological process; and d) studies of pathological process. The organization and content of the subcategories in this subsection is presented below (Fig 2). 10.1371/journal.pone.0243840.g002Fig 2 Organization and content diagram. Scope of Perfused cultures of multiple cell types section. Considering a BM as an environment composed of specific and well-established regions, the use of perfused 3D co-culture approach allows a more integrated mimicking of bone marrow niches, specifically perivascular, endosteal, and their deconstructed combination. Kotha et al. developed a 3D matrix based on hydrogel co-cultured with normal and abnormal cells that allowed the study of some important cellular processes around the perivascular niche: transmigration and the adhesion of hematopoietic cells in the healthy and pathological marrow [65]. Cell migration, cell-cell interaction, phenotypic analysis, and gene expression analysis were evaluated in this study. The results showed the device was able to represent the behavior of hematopoietic cells around the perivascular region and is a useful tool for the study of the dynamics of these cells in the niche. Still focusing on the perivascular niche mimicking, Marturano et al. presented an OoC based on a 3D scaffold of decellularized bone co-cultured with endothelial cells and mesenchymal stem [66]. The generated physiological flow was regulated in order to generate an oxygen gradient along the scaffold. The authors evaluated the formation of vessels, gene expression and histology [66] and compared the results with two control groups: static 2D, to evaluate the influence of flow and its control over oxygen and nutrient supply; and dynamic 3D in a polystyrene scaffold, to evaluate the influence of surface properties. In both cases, the device’s performance was better than the control group. In the first case, this is associated with the two-dimensional arrangement and the non-physiological design of the supply of nutrients and oxygen in the conventional method. In the second case, the composition of the scaffold surface is made of a synthetic polymer, that does not provide the cells with the necessary structure for adhesion. In addition, the synthetic polymer modified the natural cell phenotype, and consequentially altered the physiological processes of the microenvironment [66]. Furthermore, the perfused 3D co-culture approach was able to mimic another vital niche in bone marrow: the endosteal niche. The endosteal niche is a region near the spongy bone composed basically of the bone itself and the stromal cells. This niche regulates several hematopoietic processes including the quiescence [126]. From the studies that aim to mimic the endosteal niche, it was observed that this approach also allowed the development of an OoC device capable of representing the interaction between abnormal cells and the niche microenvironment. In the work that used bone cells to generate an ossified 3D matrix, Zhang et al. studied how multiple myeloma cells behaved in this environment [53]. Based on the evaluation of cell proliferation and cell-tissue interactions, this study reported the formation of a 3D arrangement between abnormal cells and bone tissue. This arrangement is responsible for a phenomenon known as “cell adhesion-mediated drug resistance”, already studied in a work that used an approach without fluid flow for the representation of BM microenvironment [54]. In another study, using the same device to assess cell viability and proliferation compared to that reported by a 3D static culture, Zhang et al. demonstrated that perfusion in the endosteal niche cultivated with multiple myeloma cells is an important factor of the microenvironment that improves the maintenance of the long-term co-culture [58]. To conclude the discussion about the use of complete systems in niche mimicking, it shall be mentioned that Aleman et al. developed an innovative deconstructed model of BM niches. Using a perfused 3D gelatin-based matrix, the authors simulated the three niches of bone marrow in a single system, identifying them as perivascular (periarterial and perisinusoidal), mesenchymal, and osteoblastic. The niches were placed in separate chambers interconnected by channels and the study reported the interaction of normal and abnormal hematopoietic cells with the niche cells and the grow factors that they release; this device created a system for the study of the physiological and pathological BM [67]. It shall be noted that despite the importance of representing BM with niche formation, most publications that have developed 'perfused 3D co-culture' devices have modeled the microenvironment as 'a general bone marrow niche' [55–57, 60, 63, 64, 68–70]. In an in vitro BM system, there are three aspects that define whether the microenvironment model is suitable for the expression of the native cell phenotype: cellular culture as in vivo; cellular processes as in vivo; and cellular response as in vivo. The most basic goal of this system is to provide cells with a microenvironment that makes them behave as in vivo. From this perspective, one way to evaluate the in vitro cell culture and to study how the environment stimulates the cells is through the modification of the arrangement of 3D BM models. As already discussed, the marrow microenvironment can be built considering specific biochemistry related to the matrix composition (e. g. proteins and biomolecules), or a specific structure related to the scaffold design (e. g. pore size and organization). Concerning the compositional approach for the representation of ECM, Wuchter et al. developed an OoC device that generates a microenvironment that stimulates hematopoietic cells to express their phenotype as in vivo [59]. The cell co-culture was composed of the progenitor mesenchymal stem cells and the ECM was generated by the mesenchymal stem cells themselves, in a cellular network that provided the complete integration of progenitor stem cells [59]. Torisawa et al. created a biomimetic hematopoietic environment based on a 3D matrix composed of type I collagen and bone powder to study the cell maintenance and culture in a mimicked native environment. This 3D matrix was inserted (subcutaneous implantation) into an animal (rat), and after 8 weeks a complete BM niche (histological analysis) was generated [55]. All niche cell types were found in the BM 3D matrix, including hematopoietic cells, and cell behavior was maintained in long-term culture. The results demonstrated this system can generate a physiological response of the BM to radiation and anti-radiation drugs (cell viability) [55]. From the structural perspective, the maintenance of the behavior of cells and their long-term culture was achieved using a well-structured 3D scaffold formed by hydroxyapatite [64]. Hydroxyapatite mimics BM very well because it is analogous to the native bone structure. Using phenotypic and gene expression analysis in HSPC and MSC in co-culture, the authors reported that it was possible to replicate cellular behavior in an experiment performed on perfusion for 28 days. The comparison with a control group confirmed that modelling the BM ECM as a 2D monolayer is a poor and very simplified representation of a complex in vivo microenvironment. Thus, the developed OoC-type devices mimic the BM microenvironment better and allow the maintenance of cell culture and replication of the in vivo cellular behavior. Furthermore, these systems also allow studying fundamental characteristics of cellular behavior: physiological processes. Hematopoiesis is one of the most important physiological processes and is responsible for the development and maturation of blood cell elements including erythrocytes, leucocytes, and platelets. Thon et al. developed a 3D system based on a hydrogel with cells stimulated by a flow-generated shear that improves platelet formation (cell differentiation analysis) compared to static 3D culture [56]. In this study, the vascular shear in microfluidic channels was the main contributor to the increase of platelet formation and for the reproduction of cell phenotype in vitro (cell morphology analysis) In addition to the devices that evaluate the production process of specific cell lines in the BM, some devices seek to represent more broadly the entire hematopoietic process, mimicking what occurs in the medullary environment. Using the previously developed device and experimental setup [55], Torisawa et al. evaluated the hematopoiesis processes in a BM-on-a-chip [60]. The results showed that after 13 days the blood cells production (histology analysis) and the hematopoietic cell behavior were maintained. This biomimetic environment simulated a physiological response of the BM to radiation and anti-radiation drugs [60]. The possibilities and results achieved with the BM OoC developed by Torisawa et al. characterize this device as an alternative to animal models [55, 60]. However, the results were based on animal cells; therefore, the translation into a human clinical trial would require the change of a protocol and a new approach to cell culture. To advance in the study of BM for clinical applications, Chou et al., in an experiment cultivating one microfluidic channel with endothelial cells and the other with hematopoietic and mesenchymal cells in a hydrogel matrix formed by type I collagen and fibrinogen, developed an in vitro system with dynamic fluid flow reproducing hematopoietic processes [70]. This BM device improved the expansion and maintenance of differentiated hematopoietic cell functions when compared to static cultures. As reported by the authors [70], the improvement compared to conventional models has also been described for the toxicity response and drug treatment, thus, showing the advances that this device offers for the study of BM pathologies. The study of pathologies in systems that mimic the three main aspects of a general BM niche can provide essential information for understanding how abnormal cells modify their surroundings and how it affects their response. In human subjects, these studies can be made in two contexts: BM as a part of a complex system (multi-organ-on-a-chip); and BM as a complex system (bone-marrow-on-a-chip). In the first context, McAleer et al. and Herland et al. developed a multi-system that improves the cells drug response [68] and provides a platform for drug screening [69]. Evaluating cell viability, cell density, chemotherapeutic assay, cell proliferation, cell quantification [68] and cell quantification, phenotypes analysis [69], both studies contributed to global understanding of the therapeutic effects of drug treatment in clinical trials. In the second context, Bruce et al. mimicked a pathological BM environment with a tri-culture system (abnormal lymphoblastic cell, mesenchymal stem cell, and osteoblast) in a perfused type I collagen-based 3D matrix and recreated the intricate network of interactions (cell-cell and cell-ECM) that actually occur in vivo microenvironments. The reported conditions are correlated with the enhanced abnormal cell survival during the drug treatment [57] and underline that the leukemic cell lines show a higher resistance to chemotherapeutic drugs than cells in 2D models. In other publications, the same phenomenon of drug resistance was reported, but with different approaches. Houshmand et al., using a macroporous model based on perfused demineralized bone 3D matrix with abnormal erythroblast cell and MSC co-cultured, found that leukemic 3D microenvironment protected the cell from drugs cytotoxicity [63]. Abnormal cells embedded in demineralized bone 3D matrix showed greater resistance to drug treatment than in 2D models. From a clinical point of view, these results contribute to understanding why some therapies for treating hematological disorders have not yet achieved the expected efficiency. Drug screening on conventional 2D platforms predicts cell response in a non-physiological environment, disregarding the dynamic environment of interactions and stimuli that exist in the human body. Here, the effect of drugs is overestimated because the model does not consider a physicochemical barrier that protects the cells from drugs [53, 54, 57, 58]. An overall conclusion from the analysis of all articles included in this revision is that the devices developed so far for mimicking the BM are effective. All publications reported results that demonstrated the effectiveness of the devices, showing an improvement in relation to conventional models and shedding new light on the knowledge about cellular phenomena in BM. However, despite the improvements and considerable success in recreating in vitro BM environment, some limitations and challenges remain. The main limitations identified in OoC devices in this systematic review were related to two vital features of BM that regulate and maintain the niche cells and hematopoietic cells: niches integration; and oxygen supply. Regarding niches integration, it is already known that BM is formed by integrating three main regions vital for BM cell behavior: endosteal, central, and perivascular. To develop an integrated system that incorporates the mentioned niches, cells-cells and ECM-cells interactions shall be considered, whether in the same niche or not. In this systematic review only one publication implemented the concept of several niches in the same OoC device [67]. However, these niches were not considered as an integrated system, since they were not physically interacting with each other and only the biochemical interaction was considered. Hence, even considering this interaction, which is also important for regulating BM cells, the lack of physical interactions and other cellular processes, e. g., cellular migration, poorly represent the dynamically complex BM microenvironment. Here, two relevant papers shall be mentioned that are still under the peer review process and were not formally included in this revision. Nelson et al. developed a device where co-culture is done with main cells that compose the three niches: osteoblasts (specific endosteal cell), endothelial cells (specific perivascular cell), mesenchymal cells, and hematopoietic cells (niches cells) [127]. The culture was implemented in a hydrogel matrix based on collagen types I and IV, fibronectin, and lamina, all components existing in the BM microenvironment [8]. However, this study does not completely consider distinct niches of the BM, failing to represent the physiological and structural/spatial aspects. Glaser et al. developed a system with distinct and interconnected chambers for the representation of the endosteal and perivascular niches. In the endosteal niche, culture was performed with osteoblasts and BM stromal cells. The perivascular niche was done with endothelial cells and BM stromal cells. Then, hematopoietic cells were grown in these niches [128]. The cells cultured in each mimicked niche were analogous to the main cell composition of the BM niches in vivo [129]. The cultures were implemented under perfusion, in a 3D matrix based on fibrin, with a hydrogel used to represent hematopoietic niches in the BM [8]. Despite the evolution in mimicking the BM niches shown in the studies by Nelson et al. and Glaser et al., they did not evaluate the hypoxia on the cellular response, failing to represent the physiological condition of oxygen concentration within the BM. Oxygen conditions in BM have a key role in cells regulation, yet it was considered only in one study included in this review [66]. The BM is a system in a state of hypoxia or low oxygen concentration. It is also important to note that there is an oxygen gradient in the niches and that the oxygen concentration is higher in the perivascular niche and lower in the endosteal niche. It was reported [15] that this parameter regulates the behavior of hematopoietic cells, and its representation in a device mimicking the BM is essential to obtain a more realistic model. This issue was raised by Chou et al., who pointed out the possibility of changing oxygen concentration to study the behavior of HSC as a function of oxygen availability [70], and also by Houshmand et al., who reported that the absence of the hypoxia condition is a limitation in mimicking the BM niche [63]. Limitations Considering that a systematic review uses a process to identify comprehensively all studies for a specific focused question, our review presents limitations linked with the adopted approach. Like many other systematic reviews, this review relies on a rather limited number of databases for the identification of potentially eligible studies. In this respect, it is worth to mention that the criteria for inclusion of studies into this review are also influenced by knowledge of the results of the set of potential studies. Other limitations are a) the use of studies published only in the English language; b) the time frame adopted (we considered published papers from January 1st, 2009 until July 24th, 2020); and c) absence of scores to assess the study quality. As a concluding remark, we shall note that as any other research, systematic reviews have potential strengths and weaknesses. Nevertheless, we believe that the presented systematic review will help the readers to stay updated about recent developments to microfluidic devices developed for representation BM. Conclusions and perspectives Understanding the limitations of conventional culture methods in mimicking the BM and motivated by the complexity of its microenvironment and its representations of niches, researchers developed in vitro culture devices of the OoC type with different levels of complexity, which repeat native behavior, processes, and responses of BM cells. This integrative systematic review was guided by the following fundamental characteristics regarding the OoC device: a) device application; b) device design; c) fluid flow generation; d) ECM composition and cell types; and e) effectiveness of OoC. We have evaluated OoC technologies that simulate BM reported from 2009 to the present moment, focusing on device development and physical and biological features of the systems. Our research has shown that OoC technology has been widely applied to study BM in several applications: biological behavior of bone marrow cells; modeling of pathological bone marrow; bone marrow niche mimicking; and drug testing. Regarding the material and fabrication process of the device, we found that the most common were the PDMS and soft-lithography, respectively. However, there are some limitations regarding the use of PDMS for building the device structure. The main limitations are the maintenance of the structure after manufacture and hydrophobicity, which is responsible for adsorption of components of culture medium and interactions with drugs. This subject requires further study for the development of new materials or treatment methods that meet the requirements of the experiments to reproduce the characteristics of BM during long periods in a reliable way. The most used mechanisms for fluid flow generation were peristaltic and syringe pumps. These mechanisms provide a physiological flow as it occurs in BM, regulating the supply of oxygen, nutrients, and growth factors. Collagen type I and alginate, which are natural polymeric materials, were the most used hydrogel types for reproducing the BM extracellular microenvironment. It is noteworthy that the 3D scaffold also was a solution for the representation of the BM, but in a macroporous approach. This approach is useful for representing the spongy bone and medullary cavities. In order to evaluate the effectiveness of OoC, first, the devices were categorized by the advances compared to the conventional methods for cell culture. These groups were defined based on three main aspects of the in vivo BM: a) 3D arrangement of BM matrix; b) cellular co-culture; and c) presence of fluid flow. In the selected publications, we identified the devices that used co-cultured, perfused, and perfused in co-culture 3D BM matrix. The results showed that the three approaches improved the maintenance of the cellular culture, the long-term culture, the cellular behavior, the cellular process, and the cellular response to drugs compared to conventional 2D and 3D static culture. However, despite these satisfactory results, the mimicking of BM has several structural and physiological limitations. Because of the complexity of BM, composed of many different cell types and structures with different physical, chemical, and biological properties, virtually all approaches have focused on mimicking specific niches with specific cell types. None of the selected studies built the BM microenvironment in vivo integrating the three niches that form it. Besides that, the hypoxic condition and the distribution of oxygen are a scarcely explored aspect that was assessed in only one publication in this systematic review. Using a simplified model to mimic BM may be sufficient to study specific and less complex problems, but because of the interaction of cells with the microenvironment and other BM cells failure to consider the three niches or the oxygen conditions leads to an incomplete mimicking of the organ in vivo. Under these circumstances, the evolution and development of new devices mimicking BM in an OoC shall consider the following aspects: a) structural and spatial aspects (the composition of ECM and the distance between the niches); b) biological aspects (main cell types present in each niche); and c) physiological aspects (fluid flow providing oxygen, nutrients, and growth factors). Emerging fabrication techniques and alternative materials used to develop the devices contribute to the evolution of BM mimicry. One of the most important of them is 3D printing. This technique allows manufacturing highly complex devices and using several materials, including polymers, resins, and biomaterials. Regarding the materials, the focus is on the least hydrophobic ones that provide flexible manufacturing. PMMA is an example of such material. The development of new OoC models should allow more complete studies of BM cells behavior and a more efficient system for studying the treatment of BM disorders. Supporting information S1 Checklist PRISMA 2009 checklist. (DOC) Click here for additional data file. S1 Table Assessment technologies and assays. (DOCX) Click here for additional data file. S1 Appendix (DOCX) Click here for additional data file. ==== Refs References 1 Raic A , Naolou T , Mohra A , Chatterjee C , Lee-Thedieck C . 3D models of the bone marrow in health and disease: Yesterday, today, and tomorrow. MRS Commun. 2019 ;9 : 37 –52 . 10.1557/mrc.2018.203 30931174 2 Gurkan UA , Akkus O . The mechanical environment of bone marrow: A review . Ann Biomed Eng . 2008 ;36 : 1978 –1991 . 10.1007/s10439-008-9577-x 18855142 3 Akhmanova M , Osidak E , Domogatsky S , Rodin S , Domogatskaya A . Physical, Spatial, and Molecular Aspects of Extracellular Matrix of In Vivo Niches and Artificial Scaffolds Relevant to Stem Cells Research . Stem Cells Int . 2015 ;2015 : 1 –35 . 10.1155/2015/167025 26351461 4 Nombela-Arrieta C , Manz MG . Quantification and three-dimensional microanatomical organization of the bone marrow . Blood Adv . 2017 ;1 : 407 –416 . 10.1182/bloodadvances.2016003194 29296956 5 Rafii S , Butler JM , Ding B-S . Angiocrine functions of organ-specific endothelial cells . Nature . 2016 ;529 : 316 –325 . 10.1038/nature17040 26791722 6 Bello AB , Park H , Lee S-H . Current approaches in biomaterial-based hematopoietic stem cell niches . Acta Biomater . 2018 ;72 : 1 –15 . 10.1016/j.actbio.2018.03.028 29578087 7 Buxboim A , Rajagopal K , Brown AEX , Discher DE . How deeply cells feel: Methods for thin gels . J Phys Condens Matter . 2010 ;22 : 194116 10.1088/0953-8984/22/19/194116 20454525 8 Nelson MR , Roy K . Bone-marrow mimicking biomaterial niches for studying hematopoietic stem and progenitor cells . J Mater Chem B . 2016 ;4 : 3490 –3503 . 10.1039/c5tb02644j 32263382 9 Nilsson SK , Johnston HM , Whitty GA , Williams B , Webb RJ , Denhardt DT , et al Osteopontin, a key component of the hematopoietic stem cell niche and regulator of primitive hematopoietic progenitor cells . Blood . 2005 ;106 : 1232 –1239 . 10.1182/blood-2004-11-4422 15845900 10 Nilsson SK , Debatis ME , Dooner MS , Madri JA , Quesenberry PJ , Becker PS . Immunofluorescence characterization of key extracellular matrix proteins in murine bone marrow in situ . J Histochem Cytochem . 1998 ;46 : 371 –377 . 10.1177/002215549804600311 9487119 11 Omatsu Y , Sugiyama T , Kohara H , Kondoh G , Fujii N , Kohno K , et al The Essential Functions of Adipo-osteogenic Progenitors as the Hematopoietic Stem and Progenitor Cell Niche . Immunity . 2010 ;33 : 387 –399 . 10.1016/j.immuni.2010.08.017 20850355 12 Shin JW , Buxboim A , Spinler KR , Swift J , Christian DA , Hunter CA , et al Contractile forces sustain and polarize hematopoiesis from stem and progenitor cells . Cell Stem Cell . 2014 ;14 : 81 –93 . 10.1016/j.stem.2013.10.009 24268694 13 Engler AJ , Richert L , Wong JY , Picart C , Discher DE . Surface probe measurements of the elasticity of sectioned tissue, thin gels and polyelectrolyte multilayer films: Correlations between substrate stiffness and cell adhesion . Surf Sci . 2004 ;570 : 142 –154 . 10.1016/j.susc.2004.06.179 14 Siler U , Seiffert M , Puch S , Richards A , Torok-Storb B , Müller CA , et al Characterization and functional analysis of laminin isoforms in human bone marrow . Blood . 2000 ;96 : 4194 –4203 . 10.1182/blood.v96.13.4194.h8004194_4194_4203 11110691 15 Wielockx B , Grinenko T , Mirtschink P , Chavakis T . Hypoxia Pathway Proteins in Normal and Malignant Hematopoiesis. Cells . 2019 ;8 : 155 10.3390/cells8020155 30781787 16 Spencer JA , Ferraro F , Roussakis E , Klein A , Wu J , Runnels JM , et al Direct measurement of local oxygen concentration in the bone marrow of live animals . Nature . 2014 ;508 : 269 –273 . 10.1038/nature13034 24590072 17 Huh D , Hamilton GA , Ingber DE . From 3D cell culture to organs-on-chips . Trends Cell Biol . 2011 ;21 : 745 –754 . 10.1016/j.tcb.2011.09.005 22033488 18 Harrison RG . The outgrowth of the nerve fiber as a mode of protoplasmic movement . J Exp Zool . 1910 ;9 : 787 –846 . 10.1002/jez.1400090405 19 Rous P. A Sarcoma of the Fowl Transmissible by an Agent Separable from the Tumor Cells . Am J Med Sci . 1911 ;13 : 397 –411 . 10.1084/jem.13.4.397 19867421 20 Wang Z , Samanipour R , Koo KI , Kim K . Organ-on-a-chip platforms for drug delivery and cell characterization: A review . Sensors Mater . 2015 ;27 : 487 –506 . 10.18494/SAM.2015.1086 21 Antoni D , Burckel H , Josset E , Noel G . Three-dimensional cell culture: a breakthrough in vivo . Int J Mol Sci . 2015 ;16 : 5517 –5527 . 10.3390/ijms16035517 25768338 22 Hoarau-Véchot J , Rafii A , Touboul C , Pasquier J . Halfway between 2D and animal models: Are 3D cultures the ideal tool to study cancer-microenvironment interactions? Int J Mol Sci . 2018 ;19 : 181 10.3390/ijms19010181 29346265 23 Breslin S , O’Driscoll L . Three-dimensional cell culture: The missing link in drug discovery . Drug Discov Today . 2013 ;18 : 240 –249 . 10.1016/j.drudis.2012.10.003 23073387 24 Lee TI , Young RA . Transcriptional regulation and its misregulation in disease . Cell . 2013 ;152 : 1237 –1251 . 10.1016/j.cell.2013.02.014 23498934 25 Esch EW , Bahinski A , Huh D . Organs-on-chips at the frontiers of drug discovery. Nat Rev Drug Discov . 2015 ;14 : 248 –260 . 10.1038/nrd4539 25792263 26 Bhatia SN , Ingber DE . Microfluidic organs-on-chips. Nat Biotechnol . 2014 ;32 : 760 –772 . 10.1038/nbt.2989 25093883 27 Whitesides GM . The origins and the future of microfluidics . Nature . 2006 ;442 : 368 –373 . 10.1038/nature05058 16871203 28 Huh D , Torisawa YS , Hamilton GA , Kim HJ , Ingber DE . Microengineered physiological biomimicry: Organs-on-Chips. Lab Chip . 2012 ;12 : 2156 –2164 . 10.1039/c2lc40089h 22555377 29 Sticker D , Rothbauer M , Lechner S , Hehenberger MT , Ertl P . Multi-layered, membrane-integrated microfluidics based on replica molding of a thiol-ene epoxy thermoset for organ-on-a-chip applications. Lab Chip . 2015 ;15 : 4542 –4554 . 10.1039/c5lc01028d 26524977 30 Ahmed I , Iqbal HMN , Akram Z . Microfluidics Engineering: Recent Trends, Valorization, and Applications. Arab J Sci Eng . 2018 ;43 : 23 –32 . 10.1007/s13369-017-2662-4 31 Whitesides GM , Ostuni E , Jiang X , Ingber DE . Soft Lithography in Biology and Biochemistry. Annu Rev Biomed Eng . 2001 ;3 : 335 –73 . 10.1146/annurev.bioeng.3.1.335 11447067 32 Ho CMB , Ng SH , Li KHH , Yoon YJ . 3D printed microfluidics for biological applications . Lab Chip . 2015 ;15 : 3627 –3637 . 10.1039/c5lc00685f 26237523 33 Becker H , Locascio LE . Polymer microfluidic devices . Talanta . 2002 ;56 : 267 –287 . 10.1016/s0039-9140(01)00594-x 18968500 34 Lee Y , Choi JW , Yu J , Park D , Ha J , Son K , et al Microfluidics within a well: An injection-molded plastic array 3D culture platform. Lab Chip . 2018 ;18 : 2433 –2440 . 10.1039/c8lc00336j 29999064 35 Ahmed I , Akram Z , Bule MH , Iqbal HMN . Advancements and potential applications of microfluidic approaches-A review. Chemosensors . 2018 ;6 10.3390/chemosensors6040046 36 Halldorsson S , Lucumi E , Gómez-Sjöberg R , Fleming RMT . Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices . Biosens Bioelectron . 2015 ;63 : 218 –231 . 10.1016/j.bios.2014.07.029 25105943 37 Griffith LG , Swartz MA . Capturing complex 3D tissue physiology in vitro . Nat Rev Mol Cell Biol . 2006 ;7 : 211 –224 . 10.1038/nrm1858 16496023 38 Sackmann EK , Fulton AL , Beebe DJ . The present and future role of microfluidics in biomedical research . Nature . 2014 ;507 : 181 –189 . 10.1038/nature13118 24622198 39 Jiang B , Zheng W , Zhang W , Jiang X . Organs on microfluidic chips: A mini review. Sci China Chem . 2014 ;57 : 356 –364 . 10.1007/s11426-013-4971-0 40 Humayun M , Chow CW , Young EWK . Microfluidic lung airway-on-a-chip with arrayable suspended gels for studying epithelial and smooth muscle cell interactions . Lab Chip . 2018 ;18 : 1298 –1309 . 10.1039/c7lc01357d 29651473 41 Musah S , Mammoto A , Ferrante TC , Jeanty SSF , Hirano-Kobayashi M , Mammoto T , et al Mature induced-pluripotent-stem-cell-derived human podocytes reconstitute kidney glomerular-capillary-wall function on a chip. Nat Biomed Eng . 2017 ;1 : 1 –12 . 10.1038/s41551-017-0069 29038743 42 Jalili-Firoozinezhad S , Prantil-Baun R , Jiang A , Potla R , Mammoto T , Weaver JC , et al Modeling radiation injury-induced cell death and countermeasure drug responses in a human Gut-on-a-Chip article . Cell Death Dis . 2018 ;9 : 1 –14 . 10.1038/s41419-017-0012-9 29298988 43 Christoffersson J , Meier F , Kempf H , Schwanke K , Coffee M , Beilmann M , et al A cardiac cell outgrowth assay for evaluating drug compounds using a cardiac spheroid-on-a-chip device . Bioengineering . 2018 ;5 : 36 10.3390/bioengineering5020036 29734702 44 Zheng W , Jiang B , Wang D , Zhang W , Wang Z , Jiang X . A microfluidic flow-stretch chip for investigating blood vessel biomechanics . Lab Chip . 2012 ;12 : 3441 –3450 . 10.1039/c2lc40173h 22820518 45 Rigat-Brugarolas LG , Elizalde-Torrent A , Bernabeu M , De Niz M , Martin-Jaular L , Fernandez-Becerra C , et al A functional microengineered model of the human splenon-on-a-chip. Lab Chip . 2014 ;14 : 1715 –1724 . 10.1039/c3lc51449h 24663955 46 Delalat B , Cozzi C , Rasi Ghaemi S , Polito G , Kriel FH , Michl TD , et al Microengineered Bioartificial Liver Chip for Drug Toxicity Screening . Adv Funct Mater . 2018 ;28 : 1 –10 . 10.1002/adfm.201801825 47 Kilic O , Pamies D , Lavell E , Schiapparelli P , Feng Y , Hartung T , et al Brain-on-a-chip model enables analysis of human neuronal differentiation and chemotaxis . Lab Chip . 2016 ;16 : 4152 –4162 . 10.1039/c6lc00946h 27722368 48 Gebauer A , Schmidt S , Hoffmann W . Status and perspective of lab-on-a-chip systems for common diseases: A systematic review from 2003 to 2013. Per Med. 2016 ;13 : 71 –91 . 10.2217/pme.15.42 29749869 49 Moher D , Liberati A , Tetzlaff J , Altman DG , Altman D , Antes G , et al Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. PLoS Med. 2009 ;6 10.1371/journal.pmed.1000097 19621072 50 Sung JH , Shuler ML . A micro cell culture analog (CCA) with 3-D hydrogel culture of multiple cell lines to assess metabolism-dependent cytotoxicity of anti-cancer drugs. Lab Chip. 2009 ;9 : 1385 –1394 . 10.1039/b901377f 19417905 51 Carrion B , Huang CPP , Ghajar CMM , Kachgal S , Kniazeva E , Jeon NLL , et al Recreating the perivascular niche ex vivo using a microfluidic approach . Biotechnol Bioeng . 2010 ;107 : 1020 –1028 . 10.1002/bit.22891 20672286 52 Sung JH , Kam C , Shuler ML . A microfluidic device for a pharmacokinetic-pharmacodynamic (PK-PD) model on a chip. Lab Chip . 2010 ;10 : 446 –455 . 10.1039/b917763a 20126684 53 Zhang W , Lee WY , Siegel DS , Tolias P , Zilberberg J . Patient-specific 3D microfluidic tissue model for multiple myeloma. Tissue Eng—Part C Methods. 2014 ;20 : 663 –670 . 10.1089/ten.TEC.2013.0490 24294886 54 Khin ZP , Ribeiro MLCC , Jacobson T , Hazlehurst L , Perez L , R Baz , et al A preclinical assay for chemosensitivity in multiple myeloma . Cancer Res . 2014 ;74 : 56 –67 . 10.1158/0008-5472.CAN-13-2397 24310398 55 Torisawa YS , Spina CS , Mammoto T , Mammoto A , Weaver JC , Tat T , et al Bone marrow-on-a-chip replicates hematopoietic niche physiology in vitro . Nat Methods . 2014 ;11 : 663 –669 . 10.1038/nmeth.2938 24793454 56 Thon JNN , Mazutis L , Wu S , Sylman JLL , Ehrlicher A , Machlus KRR , et al Platelet bioreactor-on-a-chip. Blood . 2014 ;124 : 1857 –1867 . 10.1182/blood-2014-05-574913 25606631 57 Bruce A , Evans R , Mezan R , Shi L , Moses BS , Martin KH , et al Three-dimensional microfluidic tri-culture model of the bone marrow microenvironment for study of acute lymphoblastic leukemia . PLoS One . 2015 ;10 : 1 –16 . 10.1371/journal.pone.0140506 26488876 58 Zhang W , Gu Y , Sun Q , Siegel DS , Tolias P , Yang Z , et al Ex vivo maintenance of primary human multiple myeloma cells through the optimization of the osteoblastic niche. PLoS One. 2015 ;10 : 1 –19 . 10.1371/journal.pone.0125995 25973790 59 Wuchter P , Saffrich R , Giselbrecht S , Nies C , Lorig H , Kolb S , et al Microcavity arrays as an in vitro model system of the bone marrow niche for hematopoietic stem cells . Cell Tissue Res . 2016 ;364 : 573 –584 . 10.1007/s00441-015-2348-8 26829941 60 Torisawa YS , Mammoto T , Jiang E , Jiang A , Mammoto A , Watters AL , et al Modeling Hematopoiesis and Responses to Radiation Countermeasures in a Bone Marrow-on-a-Chip. Tissue Eng—Part C Methods . 2016 ;22 : 509 –515 . 10.1089/ten.TEC.2015.0507 26993746 61 Miller PGG , Shuler MLL . Design and demonstration of a pumpless 14 compartment microphysiological system . Biotechnol Bioeng . 2016 ;113 : 2213 –2227 . 10.1002/bit.25989 27070809 62 Zheng Y , Sun Y , Yu X , Shao Y , Zhang P , Dai G , et al Angiogenesis in liquid tumors: An in-vitro assay for leukemic cell induced bone marrow angiogenesis . Adv Heal Mater . 2016 ;5 : 1014 –1024 . 10.1002/adhm.201501007 26924785 63 Houshmand M , Soleimani M , Atashi A , Saglio G , Abdollahi M , Zarif MN . Mimicking the Acute Myeloid Leukemia Niche for Molecular Study and Drug Screening. Tissue Eng—Part C Methods . 2017 ;23 : 72 –85 . 10.1089/ten.TEC.2016.0404 28007011 64 Sieber S , Wirth L , Cavak N , Koenigsmark M , Marx U , Lauster R , et al Bone marrow-on-a-chip: Long-term culture of human haematopoietic stem cells in a three-dimensional microfluidic environment . J Tissue Eng Regen Med . 2018 ;12 : 479 –489 . 10.1002/term.2507 28658717 65 Kotha SSS , Hayes BJJ , Phong KTT , Redd MAA , Bomsztyk K , Ramakrishnan A , et al Engineering a multicellular vascular niche to model hematopoietic cell trafficking . Stem Cell Res Ther . 2018 ;9 : 1 –14 . 10.1186/s13287-017-0735-7 29291747 66 Marturano-Kruik A , Nava MM , Yeager K , Chramiec A , Hao L , Robinson S , et al Human bone perivascular niche-on-a-chip for studying metastatic colonization . Proc Natl Acad Sci U S A . 2018 ;115 : 1256 –1261 . 10.1073/pnas.1714282115 29363599 67 Aleman J , George SK , Herberg S , Devarasetty M , Porada CD , Skardal A , et al Deconstructed Microfluidic Bone Marrow On-A-Chip to Study Normal and Malignant Hemopoietic Cell–Niche Interactions. Small . 2019 ;15 : 1 –13 . 10.1002/smll.201902971 31464364 68 McAleer CW , Long CJ , Elbrecht D , Sasserath T , Bridges LR , Rumsey JW , et al Multi-organ system for the evaluation of efficacy and off-target toxicity of anticancer therapeutics. Sci Transl Med. 2019 ;11 10.1126/scitranslmed.aav1386 31217335 69 Herland A , Maoz BM , Das D , Somayaji MR , Prantil-Baun R , Novak R , et al Quantitative prediction of human pharmacokinetic responses to drugs via fluidically coupled vascularized organ chips. Nat Biomed Eng. 2020 ;4 : 421 –436 . 10.1038/s41551-019-0498-9 31988459 70 Chou DB , Frismantas V , Milton Y , David R , Pop-Damkov P , Ferguson D , et al On-chip recapitulation of clinical bone marrow toxicities and patient-specific pathophysiology . Nat Biomed Eng. 2020 ;4 : 394 –406 . 10.1038/s41551-019-0495-z 31988457 71 Braham MVJ , Ahlfeld T , Akkineni AR , Minnema MC , Dhert WJA , Öner FC , et al Endosteal and Perivascular Subniches in a 3D Bone Marrow Model for Multiple Myeloma. Tissue Eng—Part C Methods . 2018 ;24 : 300 –312 . 10.1089/ten.TEC.2017.0467 29652626 72 Ratner BD . The biocompatibility manifesto: Biocompatibility for the twenty-first century. J Cardiovasc Transl Res . 2011 ;4 : 523 –527 . 10.1007/s12265-011-9287-x 21710333 73 Li G , Liu X , Du Q , Gao M , An J . Three dimensional de novo micro bone marrow and its versatile application in drug screening and regenerative medicine . Exp Biol Med . 2015 ;240 : 1029 –1038 . 10.1177/1535370215594583 26283705 74 Polini A , Prodanov L , Bhise NS , Manoharan V , Dokmeci MR , Khademhosseini A . Organs-on-a-chip: A new tool for drug discovery. Expert Opin Drug Discov. 2014 ;9 : 335 –352 . 10.1517/17460441.2014.886562 24620821 75 Becker H , Gärtner C . Polymer microfabrication technologies for microfluidic systems . Anal Bioanal Chem . 2008 ;390 : 89 –111 . 10.1007/s00216-007-1692-2 17989961 76 Ronaldson-Bouchard K , Vunjak-Novakovic G . Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development. Cell Stem Cell . 2018 ;22 : 310 –324 . 10.1016/j.stem.2018.02.011 29499151 77 Zhang B , Korolj A , Lai BFL , Radisic M . Advances in organ-on-a-chip engineering. Nat Rev Mater . 2018 ;3 : 257 –278 . 10.1038/s41578-018-0034-7 78 Sosa-Hernández JE , Villalba-Rodríguez AM , Romero-Castillo KD , Aguilar-Aguila-Isaías MA , García-Reyes IE , Hernández-Antonio A , et al Organs-on-a-chip module: A review from the development and applications perspective. Micromachines . 2018 ;9 10.3390/mi9100536 30424469 79 Ren K , Zhou J , Wu H . Materials for microfluidic chip fabrication . Acc Chem Res . 2013 ;46 : 2396 –2406 . 10.1021/ar300314s 24245999 80 Berthier E , Young EWK , Beebe D . Engineers are from PDMS-land, biologists are from polystyrenia. Lab Chip. 2012 ;12 : 1224 –1237 . 10.1039/c2lc20982a 22318426 81 Borysiak MD , Yuferova E , Posner JD . Simple, low-cost styrene-ethylene/butylene-styrene microdevices for electrokinetic applicationss . Anal Chem . 2013 ;85 : 11700 –11704 . 10.1021/ac4027675 24245911 82 Davenport Huyer L , Zhang B , Korolj A , Montgomery M , Drecun S , Conant G , et al Highly Elastic and Moldable Polyester Biomaterial for Cardiac Tissue Engineering Applications. ACS Biomater Sci Eng . 2016 ;2 : 780 –788 . 10.1021/acsbiomaterials.5b00525 83 Kolesky DB , Homan KA , Skylar-Scott MA , Lewis JA . Three-dimensional bioprinting of thick vascularized tissues . Proc Natl Acad Sci U S A . 2016 ;113 : 3179 –3184 . 10.1073/pnas.1521342113 26951646 84 Ren K , Zhao Y , Su J , Ryan D , Wu H . Convenient method for modifying poly(dimethylsiloxane) to be airtight and resistive against absorption of small molecules. Anal Chem . 2010 ;82 : 5965 –5971 . 10.1021/ac100830t 20565080 85 Sasaki H , Onoe H , Osaki T , Kawano R , Takeuchi S . Parylene-coating in PDMS microfluidic channels prevents the absorption of fluorescent dyes . Sensors Actuators, B Chem . 2010 ;150 : 478 –482 . 10.1016/j.snb.2010.07.021 86 Penzel E , Ballard N , Asua JM . Polyacrylates. Ullmann’s Encycl Ind Chem . 2000 ; 1 –20 . 87 Ali U , Karim KJBA , Buang NA . A Review of the Properties and Applications of Poly (Methyl Methacrylate) (PMMA). Polym Rev. 2015 ;55 : 678 –705 . 10.1080/15583724.2015.1031377 88 Nge PN , Rogers CI , Woolley AT . Advances in microfluidic materials, functions, integration, and applications . Chem Rev . 2013 ;113 : 2550 –2583 . 10.1021/cr300337x 23410114 89 Xia Y , Whitesides GM . Soft lithography. Annu Rev Mater Sci . 1998 ;28 : 153 –184 . 10.1002/(SICI)1521-3773(19980316)37:5<550::AID-ANIE550>3.0.CO;2-G 29711088 90 Brittain S , Paul K , Zhao X , Whitesides G . Soft lithography and microfabrication. Phys World . 1998 ;11 : 31 . 91 Verhulsel M , Vignes M , Descroix S , Malaquin L , Vignjevic DM , Viovy JL . A review of microfabrication and hydrogel engineering for micro-organs on chips. Biomaterials . 2014 ;35 : 1816 –1832 . 10.1016/j.biomaterials.2013.11.021 24314552 92 Ingber DE . From Cellular Mechanotransduction to Biologically Inspired Engineering: 2009 Pritzker Award Lecture, BMES Annual Meeting October 10, 2009 . Ann Biomed Eng . 2010 ;38 : 1148 –1161 . 10.1007/s10439-010-9946-0 20140519 93 Kapur S , Baylink DJ , Lau K-HW . Fluid flow shear stress stimulates human osteoblast proliferation and differentiation through multiple interacting and competing signal transduction pathways . Bone . 2003 ;32 : 241 –251 . 10.1016/s8756-3282(02)00979-1 12667551 94 Christophis C , Taubert I , Meseck GR , Schubert M , Grunze M , Ho AD , et al Shear stress regulates adhesion and rolling of cd44+ leukemic and hematopoietic progenitor cells on hyaluronan . Biophys J . 2011 ;101 : 585 –593 . 10.1016/j.bpj.2011.05.045 21806926 95 Yourek G , McCormick SM , Mao JJ , Reilly GC . Shear stress induces osteogenic differentiation of human mesenchymal stem cells . Regen Med . 2010 ;5 : 713 –724 . 10.2217/rme.10.60 20868327 96 Kim KM , Choi YJ , Hwang JH , Kim AR , Cho HJ , Hwang ES , et al Shear stress induced by an interstitial level of slow flow increases the osteogenic differentiation of mesenchymal stem cells through TAZ activation . PLoS One . 2014 ;9 10.1371/journal.pone.0092427 24658423 97 Diaz MF , Li N , Lee HJ , Adamo L , Evans SM , Willey HE , et al Biomechanical forces promote blood development through prostaglandin E2 and the cAMP–PKA signaling axis . J Exp Med . 2015 ;212 : 665 –680 . 10.1084/jem.20142235 25870199 98 Ando J , Nomura H , Kamiya A . The effect of fluid shear stress on the migration and proliferation of cultured endothelial cells. Microvasc Res . 1987 ;33 : 62 –70 . 10.1016/0026-2862(87)90007-0 3561268 99 Chistiakov DA , Orekhov AN , Bobryshev Y V . Effects of shear stress on endothelial cells: go with the flow. Acta Physiol. 2017 ;219 : 382 –408 . 10.1111/apha.12725 27246807 100 Byun CK , Abi-Samra K , Cho YK , Takayama S . Pumps for microfluidic cell culture . Electrophoresis . 2014 ;35 : 245 –257 . 10.1002/elps.201300205 23893649 101 Sung JH , Shuler ML . Prevention of air bubble formation in a microfluidic perfusion cell culture system using a microscale bubble trap . Biomed Microdevices . 2009 ;11 : 731 –738 . 10.1007/s10544-009-9286-8 19212816 102 Stucki JD , Guenat OT . A microfluidic bubble trap and oscillator. Lab Chip . 2015 ;15 : 4393 –4397 . 10.1039/c5lc00592b 26500046 103 Travlos GS . Normal Structure, Function, and Histology of the Bone Marrow. Toxicol Pathol. 2006 ;34 : 548 –565 . 10.1080/01926230600939856 17067943 104 Hynes RO . The extracellular matrix: not just pretty fibrils . Science . 2009 ;326 : 1216 –1219 . 10.1126/science.1176009 19965464 105 Leiva O , Leon C , Kah Ng S , Mangin P , Gachet C , Ravid K . The role of extracellular matrix stiffness in megakaryocyte and platelet development and function . Am J Hematol . 2018 ;93 : 430 –441 . 10.1002/ajh.25008 29247535 106 Zhang P , Zhang C , Li J , Han J , Liu X , Yang H . The physical microenvironment of hematopoietic stem cells and its emerging roles in engineering applications . Stem Cell Res Ther . 2019 ;10 : 1 –13 . 10.1186/s13287-018-1105-9 30606242 107 Lucas D. The Bone Marrow Microenvironment for Hematopoietic Stem Cells . Adv Exp Med Biol . 2017 ;1041 : 5 –18 . 10.1007/978-3-319-69194-7_2 29204826 108 Gattazzo F , Urciuolo A , Bonaldo P . Extracellular matrix: A dynamic microenvironment for stem cell niche . Biochim Biophys Acta—Gen Subj . 2014 ;1840 : 2506 –2519 . 10.1016/j.bbagen.2014.01.010 24418517 109 Baker BM , Chen CS . Deconstructing the third dimension-how 3D culture microenvironments alter cellular cues . J Cell Sci . 2012 ;125 : 3015 –3024 . 10.1242/jcs.079509 22797912 110 Tibbitt MW , Anseth KS . Hydrogels as Extracellular Matrix Mimics for 3D Cell Culture Mark . Biotechnol Bioeng . 2009 ;103 : 655 –663 . 10.1002/bit.22361_17 19472329 111 Lam CRI , Wong HK , Nai S , Chua CK , Tan NS , Tan LP . A 3D biomimetic model of tissue stiffness interface for cancer drug testing . Mol Pharm . 2014 ;11 : 2016 –2021 . 10.1021/mp500059q 24754837 112 Polacheck WJ , Zervantonakis IK , Kamm RD . Tumor cell migration in complex microenvironments . Cell Mol Life Sci . 2013 ;70 : 1335 –1356 . 10.1007/s00018-012-1115-1 22926411 113 Sun J , Xiao W , Tang Y , Li K , Fan H . Biomimetic interpenetrating polymer network hydrogels based on methacrylated alginate and collagen for 3D pre-osteoblast spreading and osteogenic differentiation. Soft Matter. 2012 ;8 : 2398 –2404 . 10.1039/c2sm06869a 114 Banerjee A , Arha M , Choudhary S , Ashton RS , Bhatia SR , Schaffer D V , et al The influence of hydrogel modulus on the proliferation and differentiation of encapsulated neural stem cells . Biomaterials . 2009 ;30 : 4695 –4699 . 10.1016/j.biomaterials.2009.05.050 19539367 115 Candiello J , Singh SS , Task K , Kumta PN , Banerjee I . Early differentiation patterning of mouse embryonic stem cells in response to variations in alginate substrate stiffness . J Biol Eng . 2013 ;7 : 9 10.1186/1754-1611-7-9 23570553 116 Wu J , Chen Q , Liu W , He Z , Lin JM . Recent advances in microfluidic 3D cellular scaffolds for drug assays . TrAC—Trends Anal Chem . 2017 ;87 : 19 –31 . 10.1016/j.trac.2016.11.009 117 Yuan H , Xing K , Hsu H-Y . Trinity of three-dimensional (3d) scaffold, vibration, and 3d printing on cell culture application: A systematic review and indicating future direction. Bioengineering . 2018 ;5 : 57 . 118 Domura R , Sasaki R , Ishikawa Y , Okamoto M . Cellular Morphology-Mediated Proliferation and Drug Sensitivity of Breast Cancer Cells. J Funct Biomater . 2017 ;8 : 18 10.3390/jfb8020018 28587314 119 Boulais PE , Frenette PS . Making sense of hematopoietic stem cell niches . Blood, J Am Soc Hematol. 2015 ;125 : 2621 –2629 . 10.1182/blood-2014-09-570192 25762174 120 Kobel S , Lutolf MP . High-throughput methods to define complex stem cell niches . Biotechniques . 2010 ;48 : ix –xxii . 10.2144/000113401 20569203 121 Duval K , Grover H , Han LH , Mou Y , Pegoraro AF , Fredberg J , et al Modeling physiological events in 2D vs. 3D cell culture . Physiology . 2017 ;32 : 266 –277 . 10.1152/physiol.00036.2016 28615311 122 Damiano JS , Cress AE , Hazlehurst LA , Shtil AA , Dalton WS . Cell adhesion mediated drug resistance (CAM-DR): Role of integrins and resistance to apoptosis in human myeloma cell lines. Blood . 1999 ;93 : 1658 –1667 . 10.1182/blood.v93.5.1658.405a19_1658_1667 10029595 123 Mui KL , Chen CS , Assoian RK . The mechanical regulation of integrin-cadherin crosstalk organizes cells, signaling and forces . J Cell Sci . 2016 ;129 : 1093 –1100 . 10.1242/jcs.183699 26919980 124 Goldmann WH . Mechanotransduction in cells . Cell Biol Int . 2012 ;36 : 567 –570 . 10.1042/CBI20120071 22568704 125 Ingber DE . Cellular mechanotransduction: Putting all the pieces together again . FASEB J . 2006 ;20 : 811 –827 . 10.1096/fj.05-5424rev 16675838 126 Lévesque JP , Helwani FM , Winkler IG . The endosteal osteoblastic niche and its role in hematopoietic stem cell homing and mobilization . Leukemia . 2010 ;24 : 1979 –1992 . 10.1038/leu.2010.214 20861913 127 Nelson MR , Ghoshal D , Rubio DF , Keith E , Roy K , Mejías JC , et al A Multi-Niche Microvascularized Human Bone-Marrow-on-a-Chip. bioRxiv. 2019 ; 2019.12.15.876813. 10.1101/2019.12.15.876813 128 Glaser DE , Curtis MB , Sariano PA , Rollins ZA , Shergill S , Anand A , et al Organ-on-a-chip model of vascularized human bone marrow niches . bioRxiv . 2020 . 129 Asada N , Takeishi S , Frenette PS . Complexity of bone marrow hematopoietic stem cell niche . Int J Hematol . 2017 ;106 : 45 –54 . 10.1007/s12185-017-2262-9 28534115