==== Front Clin OphthalmolClin OphthalmolClinical OphthalmologyClinical Ophthalmology (Auckland, N.Z.)1177-54671177-5483Dove Medical Press 10.2147/OPTH.S169266opth-12-1383Original ResearchComparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study Sedaghat Mohamad-Reza 1Askarizadeh Farshad 2Narooie-Noori Foroozan 3Rakhshandadi Tahereh 3Ostadi-moghadam Hadi 2Rajabi Sattar 2 1 Cornea Research Center, Khatam-Al-Anbia Hospital, Mashhad University of Medical Sciences, Mashhad, Iran 2 Refractive Errors Research Center, Mashhad University of Medical Sciences, Mashhad, Iran, asgarifarshad@yahoo.com 3 Department of Optometry, School of Rehabilitation Sciences, Zahedan University of Medical Sciences, Zahedan, IranCorrespondence: Farshad Askarizadeh, Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Vakil-abad Street, Mashhad 9177948964, Iran, Tel +98 912 143 9961, Fax +98 215 541 8080, Email asgarifarshad@yahoo.com2018 07 8 2018 12 1383 1390 © 2018 Sedaghat et al. This work is published and licensed by Dove Medical Press Limited2018The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.Purpose The aim of this study was to evaluate and compare tomographic and biometric characteristics measured by the corneal tomography and ocular biometry in bilateral keratoconus (KCN) patients with and without corneal Vogt’s striae. Methods Ninety-two eyes of 46 subjects with a reliable diagnosis of bilateral KCN with unilateral Vogt’s striae were enrolled in this cross-sectional contralateral eye study. In addition to refraction (calculated by vectorial analysis) and visual acuity, corneal tomographic measurements were obtained by the Pentacam (Scheimpflug-based anterior segment tomography). Also, ocular biometric characteristics were evaluated using the Ocuscan® RxP (ultrasound biometer). The KCN eyes were categorized into two groups, including eyes with Vogt’s striae and eyes without Vogt’s striae. Results Our results showed significant differences in the sphere, cylinder, spherical equivalent, J0, corrected and uncorrected distance visual acuity, flat, steep and maximum keratometry, anterior chamber depth (ACD), and central corneal thickness (CCT) between the two groups (all P<0.001). The eyes without Vogt’s striae had a shorter ACD measured by the Pentacam and biometer. There were no differences in axial length (AL) and vitreous length (VL) between the two groups (all P>0.05). Also, there was poor agreement between the measurements of the Pentacam and ultrasound biometer for ACD in the study groups. Conclusion Corneal tomographic and ocular biometric measurements showed significant differences between KCN eyes with and without Vogt’s striae except for AL and VL. These differences should be noticed in clinical evaluations and treatment of KCN patients. Keywords corneakeratoconuscorneal tomographyocular biometryVogt’s striae ==== Body Introduction Keratoconus (KCN) is an asymmetric, bilateral condition which may have a unilateral onset. This non-inflammatory corneal ectasia is progressive and associated with stromal thinning, irregular astigmatism, and apical corneal bulge.1,2 There are numerous reports about the prevalence of KCN, ranging from 0.05% to 2.5%.2–4 KCN impairs vision and affects the vision-related quality of life, which continues to deteriorate over time.5,6 With progression of KCN, biomicroscopic signs such as stromal thinning, corneal scars, Fleischer’s ring, and Vogt’s striae may be seen on slit-lamp biomicroscopy.1,7,8 One of the typical biomicroscopic signs of KCN is the Vogt’s striae, which may be unilateral or bilateral.8,9 The Vogt’s striae are fine vertical lines generated by compaction of the Descemet’s membrane and deep stroma that are parallel to the axis of the cone and vanish when physical compression is applied to the cornea.9 The Vogt’s striae are also known as dark and light banding patterns and stress lines.9,10 Although this condition is defined as vertical lines,9 there are some reports of unilateral or bilateral horizontal Vogt’s striae in KCN eyes.11,12 The Collaborative Longitudinal Evaluation of KCN (CLEK) study showed 34% of KCN patients have unilateral Vogt’s striae, while the striae are bilateral in 30% of the cases.8 A few studies have assessed the associations of Vogt’s striae with refractive and corneal alterations in KCN eyes.9,13 Hollingsworth and Efron evaluated the characteristics of corneal Vogt’s striae in keratoconic eyes using in vivo confocal microscopy9 and Mocan et al compared refraction and keratometry in KCN patients with and without Vogt’s striae.13 On the other hand, in novel refractive and cataract procedures [phakic intraocular lens (IOL) implantation, phacoemulsification with IOL implantation], accurate measurement of the axial length (AL) is essential to attain acceptable refractive outcomes. In addition to AL, anterior chamber depth (ACD), lens thickness (LT), vitreous length (VL), and corneal curvature are the most important factors for calculating a precise implantable IOL power.14–16 Moreover, the majority of the mentioned components in addition to corneal parameters (corneal thickness and curvature) are valuable for assessment of follow-up and treatment consequences of KCN patients.17–19 Different studies about biometric characteristics of KCN eyes have used different measurement devices without considering the Vogt’s striae.20,21 The purpose of this study was to evaluate and compare corneal tomographic and ocular biometric measurements using a Scheimpflug-based tomography and a contact ultrasound biometer in KCN eyes with and without Vogt’s striae. Methods This cross-sectional comparative-descriptive study was carried out at Sedaghat Eye Clinic, Mashhad, Iran from February to June 2017. All participants in this study were residents of Mashhad with the same ethnicity. According to the Declaration of Helsinki, written informed consent was obtained from all participants and the study was approved by the Institutional Review Board/Ethics Committee of Mashhad University of Medical Sciences. The sampling was done based on pilot study and cross-sectional nature of the study. Therefore, 92 eyes of 46 subjects with a reliable diagnosis of bilateral KCN with unilateral Vogt’s striae were enrolled in this study. All the participants underwent a comprehensive ophthalmic examination, including a full patient history, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest and cycloplegic refraction by autorefractokeratometer (KR-1, Topcon Corporation, Tokyo, Japan), irregularity of the retinoscopic reflex with scissoring in both eyes, non-contact computerized tonometry (Topcon Corporation), slit-lamp biomicroscopy, funduscopy, Scheimpflug-based anterior segment tomography (Pentacam HR, Oculus, Optikgerate GmbH, Wetzlar, Germany) and placido disc-based corneal topography (TMS4, Tomey, Enlargen, Germany). All measurements were performed between 04:00 pm and 06:00 pm by one skilled optometrist (FA). The inclusion criterion for the KCN eyes was a reliable diagnosis of KCN made by an experienced corneal refractive surgeon based on slit-lamp signs, as well as corneal topography/tomography and pachymetry maps. The inclusion criteria for KCN patients were at least one clinical sign on slit lamp biomicroscopy (Vogt’s striae, Fleischer’s ring, apical thinning, etc.),1,8 topographic signs of KCN (skewed asymmetric bow-tie, inferior steepening, etc.),22 tomographic presentations of KCN (abnormal elevation maps, abnormal pachymetry maps, KCN detection by Belin/Ambrosio Enhanced Ectasia Display III, etc.).23 The exclusion criteria in all the groups were previous eye surgery, history of corneal cross linking, corneal scars, vascularization, inflammation, opacity, history of herpetic keratitis, severe dry eye, contact lens use during the last three weeks before the examination, cataract, glaucoma or glaucoma suspect, intraocular pressure-lowering treatment, pregnancy, lactation, and underlying autoimmune or systemic diseases. Eyes diagnosed as KCN suspect or pellucid marginal degeneration were excluded from the study as well. Considering the mentioned criteria, we included 46 patients with bilateral KCN but unilateral Vogt’s striae in this study. The KCN eyes were categorized into two groups, including KCN eyes with Vogt’s striae and KCN eyes without Vogt’s striae. Then, the following corneal measurements were recorded using the Pentacam: corneal power (flat, steep and maximum keratometry), ACD, and central corneal thickness (CCT). The same experienced optometrist obtained all corneal imaging and biometric measurements in a consistent manner based on the manufacturers’ instructions and previous studies.24–27 Measurements based on quality state and index provided by Pentacam were accepted and erroneous acquisitions were repeated after 5 minutes. The mechanism of the Pentacam has been described in previous studies.24 Although studies have shown acceptable repeatability and reproducibility of the Pentacam imaging for the normal cornea,25,26 it should be considered that Pentacam measurements are variable in patients with KCN.27 Therefore, three measurements were done at 5-minute intervals with each device (the Pentacam and ultrasound biometry) for each patient and mean value of the three measurements was used for statistical analysis. Moreover, the AL, ACD, LT, and VL were measured using the Alcon Ocuscan® RxP (Alcon, Fort Worth, TX, USA) ultrasound biometer. The Ocuscan® RxP is an ophthalmic contact ultrasound device developed to measure ocular biometry in an easy to use format. This device is reliable in clinical use and we also applied this system for A-scan biometry.28 Biometry was performed at the end of the measurements to avoid its probable influence on the other imaging modalities due to corneal flattening after applanation with the ultrasound probe. The mechanism of this device and its measurement method has been discussed in other studies.28 Before performing A-scan ultrasonography, in order to anesthetize the cornea, one drop of tetracaine 0.5% (Anestocaine; Sina Darou, Iran) was instilled in each eye. Since there was no study to assess the repeatability of ultrasound biometry in the KCN eyes, the measurements were repeated three times (10 results for each measurement) per eye and the mean value of the measurements was recorded. If the SD of a measurement was greater than ±0.12 mm for AL, the measurement was rejected and the procedure was repeated until the SD was in the range of ±0.12 mm. If the participants suffered from poor fixation, low visual acuity, and high myopia, which made the results unreliable, the measurements were repeated to achieve acceptable results. To control the effect of accommodation while measuring the lens thickness, the patients were requested to look at a target placed at six meters with their fellow eye. ACD, LT, AL, and VL were noted in each eye. The manufacturer’s representative checked the calibration of the devices before the study and we did not change or adjust the default settings for corneal tomography and ocular biometry. Power vector analysis was performed to compare refraction between the two study groups. The results of spherocylindrical refraction were converted to vectors expressed by three dioptric powers: M, J0, and J45 [M=S+(C/2), J0= −C/2cos (2α), J45= −C/2sin (2α)], where M was equal to the spherical equivalent of the given refractive error, and J0 and J45 were the 2 Jackson cross cylinder equivalents to the conventional cylinder. Cycloplegic refraction was recorded in the conventional manner (sphere, cylinder, and axis) and then converted to the coordinates of the power vector as described by Thibos and Horner.29 Statistical analysis Statistical analysis was performed using Statistical Package for Social Sciences (SPSS) software version 22 (IBM Corporation, Armonk, NY, USA) and MedCalc Software version 15.8.X86 (MedCalc Software Bvba, Ostend, Belgium). Normal distribution of the parameters was assessed using the Kolmogorov–Smirnov test. A paired sample t-test was run to compare the parameters with a normal distribution while a Wilcoxon signed rank test was used to compare non-parametric parameters. Pearson correlation coefficient was run for correlative analyses. In order to study the agreement between the measurements made by devices, the Bland and Altman method was used. The 95% limits of agreement (LoA) (mean difference ±1.96 SD [SD]), which defines the range within which most differences between measurements by the two methods will lie, were calculated. P-values <0.05 were considered significant. Results We assessed 46 bilateral KCN patients [28 males (60.87%) and 18 females (39.13%)] in this study. The mean age of the participants was 26.61±6.99 years (range: 18–45 years). There were significant differences in the refractive outcomes between the two groups (all P<0.001) except for J45 (P<0.131). Some basic characteristics of the subjects are shown in Table 1. It should be mentioned that the outcomes of cycloplegic refraction were used in this study. Contralateral comparison of biometric characteristics (measured by ultrasound biometry) between KCN eyes with and without Vogt’s striae are presented in Table 2. The results of paired sample t-test showed the eyes without Vogt’s striae had shorter ACD (P=0.001) and greater LT (P=0.010), but there were no differences in AL (P=0.307) and VL (P=0.756) between the two groups. The results of the paired sample t-test showed that there were significant differences in the corneal tomographic characteristics between two study groups. Comparison of Scheimpflug-based corneal tomographic measurements between KCN eyes with and without Vogt’s striae are presented in Table 3. In KCN eyes with and without Vogt’s striae, investigations of the correlations between tomographic and biometric measurements are shown in Table 4. It should be mentioned that the Pentacam measures “internal” ACD (aqueous depth from the posterior corneal surface), whereas Ocuscan® RxP evaluates the ACD from the anterior surface of the cornea (external ACD). In order to calculate the external ACD for Pentacam results, we added the CCT and ACD values together and then performed the desired statistical analyses. As shown in Table 5, there was no correlation between the two imaging devices in terms of external ACD in two study groups (P>0.05). Also, 95% LoA were determined for better comparison of the degree of agreement between the two methods. According to Table 5 and Figure 1, there was no reasonable agreement between the measurements of the Pentacam and ultrasound biometer for external ACD in KCN eyes with and without Vogt’s striae. According to the staging scheme in CLEK study,30 keratoconic eyes were classified into three groups based on keratometry of steepest corneal meridian: mild (<45 diopters [D]), moderate (45–52 D) and severe (>52 D). In selected eyes with Vogt’s striae, 2 (4%), 10 (20%), and 38 (76%) of eyes were in mild, moderate, and severe groups, respectively, whereas in KCN eyes without Vogt’s striae, 11 (22%), 28 (56%), and 11 (22%) of eyes were in mild, moderate, and severe groups, respectively. Discussion In order to evaluate KCN eyes and to achieve the best refractive outcome after refractive (phakic IOL implantation, intracorneal ring implantation) and cataract surgery in these patients, tomographic and biometrics characteristics should be determined precisely.14–19 Meanwhile, determination of ocular biometric characteristics in patients with KCN, as the most common form of corneal ectatic disorders,1,2 is necessary to achieve the best post keratoplasty refractive outcomes, and to estimate the treatment sequels and follow-up of these patients.17 On the other hand, Vogt’s striae or stress lines, which may be visualized on slit lamp biomicroscopy, are fine vertical lines in the deep stroma that could be considered an important clinical indicator of KCN.7–10,13 To the best of our knowledge, this is the first contralateral eye study to investigate and compare corneal tomographic and ocular biometric characteristics of bilateral KCN patients with and without Vogt’s striae. Our results revealed that KCN eyes with Vogt’s striae had higher values of sphere, spherical equivalent, cylinder, and J0 than those without Vogt’s striae. Additionally, UDVA and CDVA were worse in eyes with Vogt’s striae than eyes without these lines. Using Scheimpflug-based tomography, we found that flat, steep and maximum keratometry were higher in eyes with Vogt’s striae. Also, CCT measurements revealed a thinner cornea in eyes with Vogt’s striae. The above-mentioned differences have an essential value in the clinical practice. Indeed, the presence of Vogt’s striae in keratoconic eyes seems to be an indicator of significant alterations in refractive and tomographic measurements. The results of ultrasound biometry showed no difference in AL and VL between KCN eyes with and without Vogt’s striae. However, ultrasound biometry showed that ACD in KCN eyes with Vogt’s striae was 0.1 mm deeper than those without Vogt’s striae. According to the literature, the ACD is deeper in KCN eyes in comparison to normal eyes, which may be due to morphological alterations in the cornea as formerly explained by some authors.2 However, our results showed that a deeper ACD can be seen at the presence of Vogt’s striae. Considering the effect of preoperative ACD on IOL power calculation,31,32 it seems that it is better to use new generation IOL formulas for IOL power calculation in KCN patients with Vogt’s striae. Furthermore, LT was different between KCN eyes with and without Vogt’s striae and was thicker in KCN eyes with Vogt’s striae. This difference was only statistically significant (0.04 mm, P=0.010) and further studies are needed to assess the clinical importance of it. We studied possible correlations between biometric results in KCN eyes with and without Vogt’s striae. We found an intermediate correlation between AL and ACD in KCN eyes with and without Vogt’s striae. Moreover, AL had a strong correlation with VL in KCN eyes with and without Vogt’s striae. Also, CCT, steep keratometry, maximum keratometry, and spherical equivalent were not correlated with AL, ACD, LT, and VL in either study group. Meanwhile, there was a poor correlation between flat keratometry and VL in KCN eyes with Vogt’s striae. What is certain is that the interpretation of the relationships between different ocular components is a very complex issue and is not the main focus of our study. Moreover, we evaluated the agreement between the Pentacam and ultrasound biometer for measurement of ACD but failed to find a reasonable agreement between them in the study groups. Also, the results of the present study showed a wide LoA for ACD measurements on Pentacam and ultrasound biometer in either study group. To our knowledge, this is the first study to assess the agreement among ACD measurements in KCN eyes with and without Vogt’s striae using Pentacam and ultrasound biometer. It can be concluded that one should be cautious interpreting ACD values obtained from Pentacam and ultrasound biometer in eyes with KCN. Mocan et al found an association between Vogt’s striae with refraction and corneal topography in KCN. They reported significant differences in the refractive components and steepest keratometry between patients with and without corneal Vogt’s striae.13 Our results are consistent with their findings, but it should be borne in mind that Mocan et al assessed refraction and corneal curvature and did not assess corneal tomography and ocular biometry, while we assessed clinical, tomographic, and ocular biometric parameters in a contralateral eye study in KCN patients with and without Vogt’s striae. Also, they did not use a power vector to analyze the refractive astigmatism. In another study, Hollingsworth and Efron studied the correlation between the arrangement of the Vogt’s striae in the stroma and the steepest corneal curvature of the cornea using corneal topography.9 They did not compare the clinical and subclinical findings between KCN patients with and without Vogt’s striae. It is noteworthy that no study has evaluated and compared tomographic and biometric characteristics of KCN eyes with and without Vogt’s striae; hence, we are unable to compare the results of the present study with other published articles. However, a large body of literature has described the differences between KCN and normal eyes. Although our study is remarkable for complete assessment and comparison of tomographic and biometric characteristics in KCN eyes with and without Vogt’s striae, performing this study without using in vivo confocal microscopy should be noted as a limitation. Another limitation that can be mentioned for the present study is that considering the study design and asymmetric nature of KCN, the majority of the selected eyes with Vogt’s striae had severe KCN. Although this contralateral eye study has substantial advantages, we had a limitation for matching KCN severity between two study groups. The same limitation was reported by Mocan et al in their study.13 Based on steepest keratometry values, 22% of KCN eyes without Vogt’s striae had severe KCN in the current study. Interestingly, we found that KCN eyes with clinical evidence of Vogt’s striae had worse corneal tomographic findings. Classification of KCN severity only based on keratometry values may seem rational but this staging scheme may lead us astray from a clinical point of view. The results of the present study cast doubt on the validity of keratometry-based classification of KCN severity. Therefore, it is recommended to design a study to compare clinical characteristics of KCN eyes with and without Vogt’s striae in patients who have similar steep keratometry values. Conclusion In summary, this comparative-descriptive study of keratoconic eyes with and without Vogt’s striae appear to suggest that in ophthalmic evaluation, attention should be paid to the clinical characteristics of KCN eyes with Vogt’s striae. In this case of evidence-based medicine, the results showed the association of Vogt’s striae with KCN severity. Vogt’s striae have been reported to be an indicator of KCN7 but our results showed different clinical manifestations in eyes with and without Vogt’s striae. Moreover, Pentacam and ultrasound biometry could not be used interchangeably for ACD measurement in KCN eyes. This important clinical finding should be considered in phakic IOL implantation to improve the visual outcomes of KCN eyes.18,19 It is critical to note that the present study did not aim to show the causal relationship between Vogt’s striae and clinical characteristics of KCN eyes, but to explain the association of the stromal Vogt’s striae with tomographic and biometric alterations in KCN eyes. The results of our study can be used in clinical assessment, monitoring, and treatment of KCN patients with and without Vogt’s striae. In conclusion, we found that the presence of Vogt’s striae is associated with deterioration in refractive, tomographic, and biometric findings. Acknowledgments The authors would like to thank all the willing participants in this study, without whose involvement this research would not have been possible. Disclosure The authors report no conflicts of interest in this work. Figure 1 Bland–Altman plots of the ACD measured by the Pentacam against ultrasound biometer in KCN eyes with Vogt’s striae (top) and without Vogt’s striae (bottom). The middle line in each figure is the mean difference of the values and the lines on the sides represent the upper and lower 95% LoA (mean difference ±1.96 SD). Abbreviations: ACD, anterior chamber depth; KCN, keratoconus; LoA, limits of agreement. Table 1 Contralateral comparison of basic parameters between keratoconus eyes with and without Vogt’s striae Parameter With Vogt’s striae Without Vogt’s striae Mean difference P-value Mean ± SD Range Mean ± SD Range Sph (D) −3.28±2.67 −8.75 to +1.75 −0.98±1.90 −7.25–1.50 −2.29±2.68 <0.001a Cyl (D) −5.03±2.10 −8.75 to −1.75 −2.52±1.90 −8.25–0.00 −2.51±2.28 <0.001a SE (D) −5.97±3.50 −16.62 to −0.12 −2.24±2.43 −10.12–0.88 −3.73±3.37 <0.001a J0 (D) 1.30±1.94 −4.00–7.93 0.30±0.10 −2.07–2.62 0.10±1.62 <0.001b J45 (D) 0.32±1.83 −3.71–3.13 −0.19±1.12 −3.25–2.62 0.55±2.62 <0.131a UDVA (Log MAR) 0.68±0.45 0.00–1.60 0.41±0.46 0.00–1.60 0.26±0.36 <0.001a CDVA (Log MAR) 0.31±0.30 0.00–1.00 0.09±0.11 0.00–0.40 0.23±0.26 <0.001a Notes: a Wilcoxon signed ranks test. b Paired-samples t-test. Bold values are significant. Abbreviations: Sph, sphere; Cyl, cylinder; SE, spherical equivalent; J0, Jackson cross cylinder; axes at 0° and 90°; J45, Jackson cross cylinder; axes at 45° and 135°; UDVA, uncorrected distance visual acuity; CDVA, corrected distance visual acuity; D, diopter; Log MAR, logarithm of the minimum angle of resolution. Table 2 Contralateral comparison of biometric characteristics between keratoconus eyes with and without Vogt’s striae Parameter With Vogt’s striae Without Vogt’s striae Mean difference P-valuea Mean ± SD Range Mean ± SD Range AL (mm) 23.49±0.87 21.28–25.29 23.44±0.89 20.77–25.14 0.05±0.30 0.307 ACD (mm) 3.70±0.39 2.84–4.66 3.60±0.36 2.98–4.57 0.10±0.20 0.001 VL (mm) 16.14±0.83 13.94–18.26 16.15±0.84 13.90–17.92 −0.01±0.25 0.756 LT (mm) 3.65±0.26 3.20–4.18 3.69±0.26 3.18–4.18 −0.04±0.10 0.010 Notes: a Paired-samples t-test. Bold values are significant. Abbreviations: AL, axial length; ACD, anterior chamber depth; VL, vitreous length; LT, lens thickness. Table 3 Contralateral comparison of tomographic characteristics between keratoconus eyes with and without Vogt’s striae Parameter With Vogt’s striae Without Vogt’s striae Mean difference P-value Mean ± SD Range Mean ± SD Range K1 front (D) 48.58±4.75 42.20–65.70 44.83±2.40 39.30–51.10 3.74±4.50 <0.001a K2 front (D) 53.14±5.23 43.80–71.20 47.45±3.34 40.80–56.30 5.70±5.52 <0.001b K1 back (D) −7.23±0.90 −10.20 to −5.70 −6.31±1.02 −7.60 to −0.40 −0.92±1.20 <0.001b K2 back (D) −7.63±3.06 −10.60–11.80 −7.03±0.65 −8.80 to −5.70 −0.60±3.14 <0.001b Kmax (D) 59.21±6.07 48.10–77.00 51.40±5.42 44.10–67.40 7.81±5.74 <0.001a CCT (μm) 457.20±3.25 369.00–537.00 487.13±35.80 409.00–553.00 −29.94±25.57 <0.001a ACD (mm) 3.56±0.36 2.79–4.47 3.41±0.40 2.28–4.24 0.15±0.25 <0.001a Notes: All parameters were measured by Pentacam. a Paired-samples t-test. b Wilcoxon signed ranks test. Bold values are significant. Abbreviations: K1, flat keratometry; K2, steep keratometry; Kmax, maximum keratometry; CCT, central corneal thickness; ACD, anterior chamber depth (internal). Table 4 Correlation coefficients of refractive, tomographic, and biometric characteristics of keratoconus eyes with and without Vogt’s striae Parameter ALa (mm) ACDa (mm) VLa (mm) LTa (mm) P-valuec r P-valuec r P-valuec r P-valuec r ALa (mm)  With Vogt’s striae – – 0.019 0.345 <0.001 0.928 0.333 −0.146  Without Vogt’s striae – – 0.002 0.436 <0.001 0.935 0.197 −0.194 ACDa (mm)  With Vogt’s striae – – – – 0.636 0.072 <0.001 −0.506  Without Vogt’s striae – – – – 0.081 −0.260 <0.001 −0.582 VLa (mm)  With Vogt’s striae – – – – – – 0.136 −0.224  Without Vogt’s striae – – – – – – 0.081 −0.260 CCTb (μm)  With Vogt’s striae 0.450 0.114 0.692 0.060 0.461 0.111 0.739 −0.050  Without Vogt’s striae 0.953 0.009 0.723 −0.054 0.643 0.070 0.718 −0.055 K1b (D)  With Vogt’s striae 0.062 −0.280 0.110 0.239 0.010 −0.376 0.944 −0.011  Without Vogt’s striae 0.051 −0.291 0.811 0.036 0.055 −0.285 0.821 0.034 K2b (D)  With Vogt’s striae 0.155 −0.213 0.368 0.136 0.053 −0.288 0.619 0.075  Without Vogt’s striae 0.250 −0.173 0.520 −0.097 0.342 −0.143 0.546 0.091 Kmaxb (D)  With Vogt’s striae 0.214 −0.187 0.083 0.259 0.116 −0.235 0.193 −0.195  Without Vogt’s striae 0.479 −0.107 0.873 −0.024 0.446 −0.115 0.552 0.090 SE (D)  With Vogt’s striae 0.302 −0.156 0.120 −0.232 0.497 −0.103 0.303 0.156  Without Vogt’s striae 0.941 0.011 0.497 0.103 0.497 −0.103 0.452 −0.114 Notes: a Measured by ultrasound biometer. b Measured by Pentacam. c Pearson correlation coefficient analysis. Bold values are significant. Abbreviations: AL, axial length; ACD, anterior chamber depth; VL, vitreous length; LT, lens thickness; CCT, central corneal thickness; K1, flat keratometry; K2, steep keratometry; Kmax, maximum keratometry; SE, spherical equivalent. Table 5 Pentacam and ultrasound biometer measurements for anterior chamber depth of keratoconus eyes with and without Vogt’s striae Parameter Device Pentacam Ultrasound Difference Correlation 95% LoA Mean ± SD Mean ± SD Δ P-valuea r P-value Lower Upper ACD (mm)  With Vogt’s striae 4.01±0.36 3.70±0.39 −0.31±0.53 0.0002 −0.005 0.974 −0.72 1.35  Without Vogt’s striae 3.90±0.39 3.60±0.36 −0.30±0.53 0.0004 0.006 0.968 −0.74 1.33 Notes: a Paired-samples t-test. Bold values are significant. Abbreviations: ACD, anterior chamber depth; Δ, mean difference; r, Pearson correlation coefficient; LoA, limit of agreement. ==== Refs References 1 Rabinowitz YS Keratoconus RYS Keratoconus Surv Ophthalmol 1998 42 4 297 319 9493273 2 Romero-Jiménez M Santodomingo-Rubido J Wolffsohn JS Keratoconus: a review Cont Lens Anterior Eye 2010 33 4 157 166 20537579 3 Hashemi H Beiranvand A Khabazkhoob M Prevalence of keratoconus in a population-based study in Shahroud Cornea 2013 32 11 1441 1445 24042484 4 Jonas JB Nangia V Matin A Kulkarni M Bhojwani K Prevalence and associations of keratoconus in rural maharashtra in central India: the central India eye and medical study Am J Ophthalmol 2009 148 5 760 765 19674732 5 Aydin Kurna S Altun A Gencaga T Akkaya S Sengor T Vision related quality of life in patients with keratoconus J Ophthalmol 2014 2014 4 1 7 6 Kymes SM Walline JJ Zadnik K Sterling J Gordon MO Collaborative longitudinal evaluation of keratoconus study group Changes in the quality-of-life of people with keratoconus American J Ophthalmol 2008 145 4 611 617 7 Grieve K Ghoubay D Georgeon C Stromal striae: a new insight into corneal physiology and mechanics Sci Rep 2017 7 1 13584 29051516 8 Zadnik K Barr JT Edrington TB Baseline findings in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) study Invest Ophthalmol Vis Sci 1998 39 13 2537 2546 9856763 9 Hollingsworth JG Efron N Observations of banding patterns (Vogt striae) in keratoconus: a confocal microscopy study Cornea 2005 24 2 162 166 15725884 10 Somodi S Hahnel C Slowik C Richter A Weiss DG Guthoff R Confocal in vivo microscopy and confocal laser-scanning fluorescence microscopy in keratoconus Ger J Ophthalmol 1996 5 6 518 525 9479549 11 Chung SH Kim EK Keratoconus with unilateral horizontal stress lines Cornea 2005 24 7 890 16160514 12 Güngör IU Beden U Sönmez B Bilateral horizontal Vogt’s striae in keratoconus Clin Ophthalmol 2008 2 3 653 655 19668769 13 Mocan MC Yilmaz PT Irkec M Orhan M The significance of Vogt’s striae in keratoconus as evaluated by in vivo confocal microscopy Clin Exp Ophthalmol 2008 36 4 329 334 18700919 14 Olsen T Calculation of intraocular lens power: a review Acta Ophthalmol Scand 2007 85 5 472 485 17403024 15 Bozorg S Pineda R Cataract and keratoconus: minimizing complications in intraocular lens calculations Semin Ophthalmol 2014 29 5–6 376 379 25325863 16 Guerra MG Silva AMM Marques SHM Phakic intraocular lens implantation: refractive outcome and safety in patients with anterior chamber depth between 2.8 and 3.0 versus $3.0 mm Ophthalmic Res 2017 57 4 239 246 28199995 17 Ernst BJ Hsu HY Keratoconus association with axial myopia: a prospective biometric study Eye Contact Lens 2011 37 1 2 5 21178694 18 Esteve-Taboada JJ Domínguez-Vicent A Ferrer-Blasco T Alfonso JF Montés-Micó R Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients J Cataract Refract Surg 2017 43 1 115 130 28317664 19 Kato N Toda I Hori-Komai Y Sakai C Arai H Tsubota K Phakic intraocular lens for keratoconus Ophthalmology 2011 118 3 605.e2 605.e2 21376252 20 Cınar Y Cingü AK Sahin M Comparison of optical versus ultrasonic biometry in keratoconic eyes J Ophthalmol 2013 2013 481238 23986865 21 Aurich H Pham DT Wirbelauer C Biometric evaluation of keratoconic eyes with slit lamp-adapted optical coherence tomography Cornea 2011 30 1 56 59 20861721 22 Matalia H Swarup R Imaging modalities in keratoconus Indian J Ophthalmol 2013 61 8 394 400 23925322 23 Belin MW Ambrósio R Scheimpflug imaging for keratoconus and ectatic disease Indian J Ophthalmol 2013 61 8 401 406 23925323 24 Oliveira CM Ribeiro C Franco S Corneal imaging with slit-scanning and Scheimpflug imaging techniques Clin Exp Optom 2011 94 1 33 42 20718786 25 Lackner B Schmidinger G Pieh S Funovics MA Skorpik C Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound Optom Vis Sci 2005 82 10 892 899 16276321 26 Mcalinden C Khadka J Pesudovs K A comprehensive evaluation of the precision (repeatability and reproducibility) of the Oculus Pentacam HR Invest Ophthalmol Vis Sci 2011 52 10 7731 7737 21810981 27 Vianna LM Muñoz B Hwang FS Gupta A Jun AS Variability in Oculus Pentacam tomographer measurements in patients with keratoconus Cornea 2015 34 3 285 289 25625364 28 Sohajda Z Papp J Berta A Módis L The comparative study of two recently developed A-scan devices: determination of central corneal thickness, anterior chamber depth and axial length Acta Ophthalmol 2008 86 1 45 48 17651470 29 Thibos LN Horner D Power vector analysis of the optical outcome of refractive surgery J Cataract Refract Surg 2001 27 1 80 85 11165859 30 Zadnik K Barr JT Gordon MO Edrington TB Biomicroscopic signs and disease severity in keratoconus. Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group Cornea 1996 15 2 139 146 8925661 31 Miraftab M Hashemi H Fotouhi A Khabazkhoob M Rezvan F Asgari S Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length Middle East Afr J Ophthalmol 2014 21 4 307 311 25371635 32 Jeong J Song H Lee JK Chuck RS Kwon JW The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas BMC Ophthalmol 2017 17 1 62 28464806