==== Front Ann Card AnaesthAnn Card AnaesthACAAnnals of Cardiac Anaesthesia0971-97840974-5181Medknow Publications & Media Pvt Ltd India 30052228ACA-21-32110.4103/aca.ACA_238_17Interesting ImagesA Curious Case of Raised Gradient Across Mitral Bioprosthetic Valve Raut Monish S Hanjoora Vijay Mohan Chishti Murtaza A 1Govil Akhil 1Pandey Rakesh Jyoti Aman Mahavar Ravi Kumar Kandpal Shweta Suri Rathor Dileep Kumar Singh 1Department of Cardiac Anaesthesiology, Artemis Hospitals, Haryana, Gurgaon, India1 Department of Cardiac Surgery, Artemis Hospitals, Haryana, Gurgaon, IndiaAddress for correspondence: Dr. Monish S Raut, Department of Cardiac Anaesthesiology, Artemis Hospitals, Gurgaon, India. E-mail: drmonishraut@gmail.comJul-Sep 2018 21 3 321 322 Copyright: © 2018 Annals of Cardiac Anaesthesia2018This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.High Doppler valve gradient is generally suggestive of valve thrombosis. However, it should be corroborated with the finding of restricted leaflet movement to confirm the diagnosis. In the present case, abnormally high gradient was not associated with limited leaflet movements or any valve thrombus. Diastolic dysfunctiondigoxintransmitral gradient ==== Body A 52-year-old female patient presented with shortness of breath on mild exertion. She was diagnosed with rheumatic heart disease with severe mitral stenosis and severe tricuspid regurgitation. Transthoracic echocardiography was suggestive of critical mitral stenosis (mitral valve area 0.8 cm2). Mean gradient across mitral valve was 12 mm Hg and severe tricuspid regurgitation with pulmonary artery systolic pressure of around 65 mm Hg was observed. Left ventricular ejection fraction was 58% with no diastolic dysfunction. She had atrial fibrillation with controlled ventricular rate. Coronary angiography was normal. The patient underwent mitral valve replacement with bioprosthetic valve Epic 29 mm (St. Jude) and tricuspid valve repair. After the surgery, the patient was hemodynamically stable. Mean gradient across mitral prosthetic valve was 2 mm Hg with no paravalvular leak. Regurgitation across tricuspid valve was just trivial. Oral anticoagulant warfarin was started to maintain therapeutic anticoagulation range. Postoperatively, the patient started taking tablet digoxin 0.25 mg for atrial fibrillation as advised by her local physician. Few days after the surgery, the patient complained of breathlessness even after mild exertion. Transthoracic echocardiographically was performed, and it revealed a mean gradient of 13 mm Hg across the mitral prosthetic valve at a heart rate of 88/min [Figure 1]. Prosthetic mitral valve leaflets were functioning well [Video 1]. Moderate tricuspid regurgitation with peak velocity of 3.8 m/s was noted [Figure 2]. Left atrium was dilated, and average E/e’ ratio was 16 suggestive of Grade 3 diastolic dysfunction of the left ventricle. Left ventricular systolic function was good with left ventricular ejection fraction approximately 50% [Video 2]. Figure 1 Transthoracic echocardiography apical four-chamber view showing gradient across mitral bioprosthetic valve Figure 2 Transthoracic echocardiography showing peak gradient of tricuspid regurgitation High Doppler valve gradient is generally suggestive of valve thrombosis. However, it should be corroborated with the finding of restricted leaflet movement to confirm the diagnosis. In the present case, abnormally high gradient was not associated with limited leaflet movements or any valve thrombus. Incidence of bioprosthetic valve thrombosis is low.[1] There was no evidence of any valve thrombosis or valve degeneration echocardiographically. The patient was well anticoagulated. Sometimes, preserved mitral leaflets may cause elevated gradient across the prosthetic valve. However, thickened and calcified mitral apparatus was not spared in the present case. However, it is important to note that echocardiography indicated severe left ventricular diastolic dysfunction which could have increased the transmitral gradient. The patient was not having diastolic dysfunction preoperatively and in the immediate postoperative period. Chronic atrial fibrillation might have developed diastolic dysfunction. Atrial fibrillation is both a cause and consequence of heart failure (both in heart failure with reduced ejection fraction and preserved ejection fraction).[2] Moreover, the patient was on digoxin therapy postoperatively. Digoxin, by inhibiting Na-K-ATPase membrane pump, increases cytosolic Ca2+ concentrations and thereby enhances myocardial contractility. Rapid restoration of this raised calcium to basal levels in early diastole can only ensure myocardial relaxation. Digoxin is not expected to facilitate relaxation as evidenced in several experimental studies[34] and did not offer beneficial effects in patients with diastolic failure as evidenced by the Ancillary Digitalis Investigation Group Trial.[5] In the present case, raised transmitral gradient may be because of diastolic dysfunction probably due to atrial fibrillation and exaggerated by digoxin. The patient was decongested using loop diuretic. Digoxin was stopped, and beta blocker was started as rate control therapy for atrial fibrillation. The patient improved symptomatically. Declaration of patient consent The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest. Videos available on: www.annals.in ==== Refs 1 McGrath LB Fernandez J Laub GW Anderson WA Bailey BM Chen C Perioperative events in patients with failed mechanical and bioprosthetic valves Ann Thorac Surg 1995 60 S475 8 7646211 2 Kotecha D Piccini JP Atrial fibrillation in heart failure: What should we do? Eur Heart J 2015 36 3250 7 26419625 3 Massie BM Abdalla I Heart failure in patients with preserved left ventricular systolic function: Do digitalis glycosides have a role? Prog Cardiovasc Dis 1998 40 357 69 9449960 4 Lorell BH Isoyama S Grice WN Weinberg EO Apstein CS Effects of ouabain and isoproterenol on left ventricular diastolic function during low-flow ischemia in isolated, blood-perfused rabbit hearts Circ Res 1988 63 457 67 3396161 5 Ahmed A Rich MW Fleg JL Zile MR Young JB Kitzman DW Effects of digoxin on morbidity and mortality in diastolic heart failure: The ancillary digitalis investigation group trial Circulation 2006 114 397 403 16864724