==== Front Med Sci MonitMed. Sci. MonitMedical Science MonitorMedical Science Monitor : International Medical Journal of Experimental and Clinical Research1234-10101643-3750International Scientific Literature, Inc. 3005188910.12659/MSM.909294909294Animal StudyAn Experimental Study of Femto-Laser in Assisting Xenograft Acellular Cornea Matrix Lens Transplantation Zheng Xiaoli 1BDZhang Dan 1EGLi Siyuan 1DFZhang Jing 1ACZheng Juan 2BDDu Liqun 3EGGao Jianlu 1AC 1 Department of Ophthalmology, Liaocheng City People’s Hospital, Liaocheng, Shandong, P.R. China 2 Department of Joint Laboratory for Translational Medicine Research, Liaocheng City People’s Hospital, Liaocheng, Shandong, P.R. China 3 Department of Ophthalmology, Qilu Hospital of Shandong University, Qilu, Shandong, P.R. ChinaCorresponding Author: Jianlu Gao, e-mail: jianlugaot@126.comA Study Design B Data Collection C Statistical Analysis D Data Interpretation E Manuscript Preparation F Literature Search G Funds Collection 2018 27 7 2018 24 5208 5215 01 2 2018 11 2 2018 © Med Sci Monit, 20182018This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)Background The aim of this study was to evaluate the feasibility of using a femto-laser in assisting xenograft cornea matrix lens transplantation in correcting ametropia, along with evaluating the effectiveness and predictability of this procedure. Material/Methods A corneal matrix pouch was prepared on the right eyes on 8 healthy New Zealand rabbits by a femto-laser that was also employed to perform small incision lenticule extraction (SMILE) on 8 bovine cornea matrix lenses (+6D). A lens was treated acellular and implanted into a right rabbit cornea matrix pouch. Surface inflammation was observed at 1, 2, 4, 8, 12, and 24 weeks after surgery. Anterior ocular segment optical coherence tomography (OCT), corneal topography, retinoscopy, and cornea endothelial cell enumeration were performed. Results All the surgeries were successfully performed without any complications. The hyperopia condition of the rabbit eyes transformed into myopia status at an early stage and gradually developed hyperopia. Diopter at 24 weeks after surgery was 1/3 of that before surgery. Central corneal thickness stabilized at 4 weeks after surgery. Anterior segment OCT showed a clear lens edge at early post-operative stage, and blurred edge at 24 weeks later, indicating gradual fusion with the rabbit corneal matrix. Conclusions Femto-laser assisted xenograft corneal matrix lens transplantation is safe and effective in correcting ametropia, with satisfactory predictability, thus providing novel choice for correcting ametropia. MeSH Keywords CorneaFeasibility StudiesTransplantation, Heterologous ==== Body Background VisuMax femto-laser is a near-infrared pulse laser with unique feature, including short pulse duration, high peak power, and minor heating effective region [1–5]. Small incision leticule extraction (SMILE) is generally performed by 2 laser scans at different depths by femto-laser within the corneal matrix to generate one corneal matrix lens with specific thickness and size, which can be extracted via 2~4 mm side incision, thus correcting ocular ametropia status and treating myopia or astigmatism [6–10]. During SMILE, one piece of corneal matrix lens tissue with certain diopter degree is removed at one time, and consequent autograft/xenograft transplantation largely improves corneal ametropia surgery, thus providing new insights for treating hyperopia or conical corneal [11–14]. This study prepared xenograft (bovine) corneal matrix lenses with certain diopter degree, followed by acellular treatment and transplantation into rabbit corneal matrix pouches to observe the effect of xenograft corneal matrix lens transplant on diopter status, corneal thickness, and corneal endothelial cells after surgery, in order to evaluate the feasibility, effectiveness, and predictability of xenograft corneal matrix lens transplantation in correcting ametropia. Material and Methods Preparation of acellular bovine corneal matrix lens A total of 8 fresh bovine eyeballs were treated with VisuMax femto-laser SMILE. Surgical parameters were: corneal cap diameter=7.5 mm; corneal cap thickness=120 μm; side incision locates at 270° location; arch length=5 mm; diopter=−6.0 DS; lens diameter=7.00 mm; maximal central thickness of corneal matrix lens=126 μm. Extracted corneal lenses were treated with 0.5% sodium dodecyl sulfate (SDS) for 24 hours to generate acellular bovine corneal matrix lenses, which were sterilized by ethylene oxide. Experimental animals A total of 8 healthy adult New Zealand rabbits (males and females, body weight 2.5~3 kg) were purchased from Lukang Experimental Animal Center (Certificate No. SCXK-20150001) and were kept for 2 weeks. Then 24 hours before surgery, silt lamp microscopy was performed to examine any abnormality in ocular tissues. One eye from each rabbit was selected as the surgical eye. Acellular reagent SDS was purchased from Sigma (US). Surgical approach and post-op medication For anesthesia, we used 10% hydrate chloroform (3 mL/kg, intraperitoneal injection) and 0.4% Benoxil (ocular surface dropping). FS-LASIK surgery under femto-laser was performed with following parameters: corneal flap diameter=7.9 mm; corneal flap thickness=100 μm; side incision angle=70°; pedicle locations are 240° right and 305° left; pedicle angle=315°; pedicle width=21.72 mm. The pouch was prepared by iris repository for laminar separation. Acellular bovine corneal matrix lens was implanted into the pouch and was placed in the central site. Tobramycin-dexamethasone paste was applied inside the conjunctival pouch after surgery. The surgical protocol is shown in Figure 1. One week after surgery, tobramycin-dexamethasone eye drops were applied 3 times daily, along with tobramycin-dexamethasone paste once every night. Post-operation examinations Ocular surface inflammation The eye was examined for ocular surface inflammation. A slit-lamp was used to observe any congestion, edema, corneal swelling or turbidity, angiogenesis, anterior chamber inflammation, transparency or translocation of implant materials, and any detachment of implants. Anterior segment OCT Anterior segment optical coherence tomography (OCT) was employed to observe any reductus or translocation of implanted cornea matrix lens. Build-in measurement software quantified central thickness of cornea in triplicates. Retinoscopy A retinoscopy examination was performed. Anterior segment analyzing system (Oculus pentacam, Germany) was applied to plot retinoscopy at specific time points before and after surgery in triplicated measurements. Averaged k-value was obtained from multiple measurements. Retinoscopy optometry A retinoscopy optometry examination was performed. Mydriasis was performed using tropicamide eye drops before and 2, 4, 8, 12, and 24 weeks after surgery. Rabbit eyes were examined under optometry by the same clinicians. Enumeration of corneal endothelial cells Corneal endothelial cell examination was performed. A cell counter for retinal endothelial cells (TOPCON, Japan) was used to measure density of corneal endothelial cells, and percentage of hexagonal cells, for statistical analysis. Plasma CD4 and CD8 assay A plasma CD4 and CD8 assay was performed 2 weeks after surgery, using 2 mL venous blood samples collected from rabbit ear vessels. Anti-coagulated blood samples were centrifuged to separate plasma. Dual-antibody sandwich approach was employed to quantify protein expression level. In brief, micro-well plate with purified antibody pre-coating was prepared and serum proteins added, followed by binding with HRP-labelled antibody to form antibody-antigen-enzyme labelled antibody complex. After complete washing, TMB substrate was added. Under HRP enzymatic catalyze, TMB was transformed to produce blue precipitations, and later, under acid treatment a final yellow color. The intensity of color is positively correlated with sample protein concentration. Optical density (OD) value at 450 nm was measured under a microplate reader. Serum protein concentration was calculated based on standard curves. Corneal morphometry Rabbits were scarified 24 weeks after surgery using air thrombosis. The corneas were extracted and fixed in 10% formalin, embedded in paraffin, and stained in hematoxylin and eosin (H&E) staining method. Pathology and morphometry were observed under a light field microscope. Representative fields were captured. Results General conditions of post-operative ocular tissues All rabbit eye transplants showed no dissolving or necrosis during the observation window, without any reductus or translocation of lenses. At the first day after surgery, surgical eye retinas showed edema, becoming transparent at 2 weeks after surgery. Until 24 weeks post-operation, no corneal inflammation, turbidity, or angiogenesis was observed (Figure 2). Anterior segment OCT Two weeks after surgery, corneas presented with edema and obvious anterior/posterior lens edge. Four weeks after surgery, corneal edema disappeared, and showed blurred lens edge at 24 weeks post-operation (Figure 3). Thickness of central cornea Central corneal thickness was increased by 186.87 μm at 2 weeks post-operation compared to before surgery, with a statistically significant difference (P<0.001). The thickness of the central cornea stabilized at 4 weeks after surgery. One-way analysis of variance (ANOVA) indicated that all data fitted equal variance hypothesis (F=2.501, P=0.08 >0.05). No statistical significance was found at 4, 8, 12, and 24 weeks after surgery (Table 1). Retinoscopy results All rabbit eyes showed hyperopia before surgery and reached expected diopter at 2 weeks after surgery. Diopter degree then drifted towards hyperopia and stabilized at 8 weeks after surgery. At 24 weeks after surgery, the diopter was only 1/3 of that before surgery. One-way ANOVA showed equal variance among all dataset (F=2.501, P=0.08 >0.05). Therefore all 8 groups showed no statistically significant differences at 8, 12, and 24 weeks after surgery (Table 2). Corneal endothelial cell density As shown in Table 3, one-way ANOVA showed all data fitted equal variance hypothesis (F=1.559, P=0.193 >0.05), indicating no statistically significant differences among all data points before or after surgery. Corneal topography Due to larger pupil size and worse gazing performance of rabbit eyes, corneal topography showed relatively larger variations, making the statistical analysis more difficult (Figure 4). Plasma CD4 and CD8 assay results Relative expression levels of plasms CD4 and CD8 were compared at various time points between experimental and control groups using independent samples t-test. No statistical significant difference was found among the 2 groups (Figure 5). Histopathology examination At 24 weeks after surgery, the intact corneal structure was observed, with fusion between the acellular corneal matrix lens and peripheral matrix, and no significant cleft or infiltration of inflammatory cells. Few matrix cells invade into the corneal matrix lens (Figure 6). Discussion Currently, the major surgical approach to correct ametropia is a “resection” plan, including the resection of the cornea to change its curvature. This method, however, makes the cornea thinner, leading to potential risk of cornea dilation or conical cornea after surgery [15,16]. This study thus evaluated the possibility of femto-laser assisted xenograft cornea matrix lens transplantation, which would revolutionize ametropia surgery. Previous studies have focused on autograft or allograft transplantation. Sun et al. performed femto-laser assisted lens extraction surgery to implant lenses from myopia eyes of patients through transplantation into the pouches of hyperopia eyes [17], and reported short-term safety and effectiveness, with satisfactory predictability. Zhang et al. performed autograft lens transplantation by the SMILE approach and showed satisfactory bio-compatibility [18]. However, there are limited sources for human corneal lenses for transplants and only a few cases meet the criteria for autograft transplants. Therefore, xenograft transplantation may have a more promising future. Bovine corneas are in sufficient supply and can be used to prepare corneal matrix lenses with specific diopter, and can be used to correct severe myopia, hyperopia, or presbyopia after acellular treatment. Zhang et al. utilized acellular bovine corneal matrix by histo-engineering (Ainier Corneal Engineering Corp, China) for laminar corneal transplants and showed safety and effectiveness for treating fungal corneal ulcer and potency in treating eye diseases [19]. We also reviewed previous studies using xenograft corneal matrix lens transplantation, and prepared bovine lenses with acellular treatment and consequent transplantation into rabbit eyes. Results showed safety and effectiveness with good bio-compatibility with acellular corneal lens transplants [20,21]. This study further observed the effect on diopter, corneal thickness, and endothelial layer after transplantation of bovine lenses. Within days of surgery, cornea tissues showed edema, with transparency occurring at 2 weeks after surgery, which was consistent with results from rabbit autograft lens transplants or monkey xenograft lens transplants. Implanted lenses showed satisfactory bio-compatibility, probably due to the lack of blood vessels or lymph tubes in the corneas that help reduce immune system rejection after cornea transplantation. Moreover, the donor corneal matrix lens used in our experiment underwent acellular treatment to remove cell and antigen components. Rejection of transplanted cornea is mainly due to late onset hypersensitive response induced mainly by T lymphocytes [22]. Host CD4 and CD8 positive cells have been directly correlated with rejection of transplantation [23]. In our study, plasma CD4 and CD8 levels were measured at various time points in the experimental group and the control group, and we found no statistically significant differences between the 2 groups, and thus no rejection after lens implantation. Anterior ocular segment OCT and corneal thickness showed remodeling of the cornea after lens transplantation. Corneal endothelial cell density assay showed no major effect on corneal endothelial layer of the xenograft matrix lens transplantation. Histopathology results showed fusion between corneal matrix lens and peripheral corneal matrix of recipient, without inflammatory cell infiltration. The traumatic-healing response of corneal matrix lens extraction and pouch preparation was minor due to small incision and no suture lines. Our retinoscopy, however, did not obtain expected results. All rabbit eyes showed hyperopia status before surgery and reached expected diopter at 2 weeks after surgery. The diopter then drifted towards hyperopia and stabilized at 8 weeks after surgery. At 24 weeks after surgery, the diopter degree only reached 1/3 of that before surgery. Diopter is determined not only by thickness of implanted lens, but also includes changes in corneal curvature at both front and back side, as well as corneal epithelial remodeling, Other possible reasons included worse gazing of rabbit eyes and consequent off-axis of lens. A previous study also showed difficulty in determining central point during lens extraction, mainly due to the rotation away from the center of rabbit eyes after anesthesia [24]. Such circumstances, however, may not occur in patients with satisfactory gazing performance. Pradhan et al. extracted corneal matrix lenses from severe myopia patient eyes and then implanted the lenses into the corneal matrix pouches of hyperopia patients [25]. The corneas maintained transparent after surgery, but only reached 1/2 of the expected correction of diopter degree. Therefore, surgical plan of lens implantation to correct hyperopia should include the effect of corneal reshaping on the diopter degree, rather than the simple summation of diopter degree. In considering both physical and biological effects, larger-sample experimental datasets are required to elucidate a related formula, indicating infeasibility of promoting this transplantation approach into clinical practice. Conclusions Femto-laser assisted xenograft acellular corneal matrix lens transplantation has satisfactory safety and predictability. The SMILE approach can be used to prepare bovine corneal matrix lenses with specific diopter degree and shape. After acellular treatment, femto-laser can be applied to prepare the recipient corneal matrix pouch. Such xenograft corneal matrix lens transplants can be used to correct myopia and hyperopia, revolutionizing the ametropia surgery from “subtraction” into “addition”, and also provide novel insights for treating corneal dilation and conical cornea. Conflict of interest None. Source of support: This work was supported by Project of Shandong Natural Science Foundation of China (No. ZR2015HL053); Shandong medical and health science and technology development plan (No. 2015WS0383); Project of Shandong Natural Science Foundation of China (No. ZR2012HM019) and Project on the National Natural Science Foundation of China (No. 3057199) Figure 1 Brief outline of surgical protocols. Figure 2 Post-operative (post-op) cornea condition. (A) 1-day post-op; (B) 2 weeks post-op; (C) 4 weeks post-op; (D) 8 weeks post-op; (E) 12 weeks post-op; (F) 24 weeks post-op. Figure 3 Ocular anterior OCT images. (A) 1-day post-operative (post-op); (B) 2 weeks post-op; (C) 4 weeks post-op; (D) 8 weeks post-op; (E) 12 weeks post-op; (F) 24 weeks post-op. OCT, optical coherence tomography. Figure 4 Corneal tomography at all time points after surgery. Figure 5 Plasma CD4 and CD8 assays after surgery. Figure 6 Corneal tissue structures at 24 weeks after surgery. (A–C) show different angles (hemoxylin and eosin staining, 400×). Table 1 Mean central corneal thickness at each observing time point (in μm). Group Before After 2 W 4 W 8 W 12 W 24 W 1 367 559* 414 406 405 402 2 362 546* 408 411 406 399 3 380 568* 409 409 407 406 4 354 539* 416 412 410 411 5 387 561* 418 418 413 415 6 361 552* 411 410 409 405 7 359 553* 403 409 403 397 8 371 558* 413 411 410 412 * p<0.05 compared to those before surgery. Table 2 Mean spherical equivalents at each observing time (D). Group Before After 2 W 4 W 8 W 12 W 24 W 1 +3.50 −2.50 −0.50 +1.00 +0.75 +1.50 2 +4.00 −2.75 −1.00 +1.00 +1.00 +1.00 3 +3.00 −2.00 −1.50 +1.25 +1.50 +1.50 4 +3.25 −2.50 −1.00 +0.75 +1.50 +1.00 5 +3.75 −2.50 −1.50 +0.75 +1.25 +1.50 6 +3.50 −2.75 −1.25 +1.25 +1.00 +1.25 7 +4.25 −2.25 −0.75 +1.25 +0.75 +1.25 8 +3.00 −3.00 −1.50 +1.00 +1.00 +1.00 Table 3 Corneal endothelial cell density at each observing time. Group Before After 2 W 4 W 8 W 12 W 24 W 1 2296.5 2314.2 2323.1 2286.5 2247.7 2313.4 2 2347.1 2352.7 2509.4 2356.7 2287.1 2439.0 3 2221.6 2501.1 2300.6 2122.6 2089.3 2445.7 4 2358.0 2511.0 2343.3 2289.9 2374.2 2139.0 5 2412.6 2572.3 2731.4 2262.1 2233.8 2257.8 6 2379.5 2385.5 2264.1 2514.3 2232.7 2372.5 7 2377.3 2431.3 2389.2 2354.9 2511.3 2367.6 8 2179.3 2111.9 2415.3 2345.6 2137.1 2419.4 ==== Refs References 1 Farjo AA Sugar A Schallhorn SC Femtosecond lasers for LASIK flap creation: A report by the American Academy of Ophthalmology Ophthalmology 2013 120 3 e5 20 2 Soong HK Malta JB Femtosecond lasers in ophthalmology Am J Ophthalmol 2009 147 2 189 97.e2 18930447 3 Ohta M Hosokawa Y Hatano N Efficacy of femtosecond lasers for application of acupuncture therapy Lasers Med Sci 2016 32 9 1 5 27640001 4 Roberts TV Femtosecond lasers in cataract surgery Clin Exp Ophthalmol 2016 44 545 46 27758073 5 Bala C Pattamatta U Chan T Transection and explantation of intraocular lenses using femtosecond lasers J Cataract Refract Surg 2017 43 420 23 28410727 6 Shah R Shah S Sengupta S Results of small incision lenticule extraction: All-in-one femtosecond laser refractive surgery J Cataract Refract Surg 2011 37 127 37 21183108 7 Sekundo W Kunert K Russmann C First efficacy and safety study of femtosecond lenticule extraction for the correction of myopia: Six-month results J Cataract Refract Surg 2008 34 1513 20 18721712 8 Fernandez J Rodriguez-Vallejo M Martinez J New parameters for evaluating corneal biomechanics and intraocular pressure after small-incision lenticule extraction by Scheimpflug-based dynamic tonometry J Cataract Refract Surg 2017 43 803 11 28732615 9 Hosny M Aboalazayem F El Shiwy H Comparison of different intraocular pressure measurement techniques in normal eyes and post small incision lenticule extraction Clin Ophthalmol 2017 11 1309 14 28761329 10 Khalifa MA Ghoneim AM Shaheen MS Vector analysis of astigmatic changes after small-incision lenticule extraction and wavefront-guided laser in situ keratomileusis J Cataract Refract Surg 2017 43 819 24 28732617 11 Reinstein DZ Pradhan KR Carp GI Small incision lenticule extraction (SMILE) for hyperopia: Optical zone diameter and spherical aberration induction J Refract Surg 2017 33 370 76 28586496 12 Reinstein DZ Pradhan KR Carp GI Small incision lenticule extraction (SMILE) for hyperopia: Optical zone centration J Refract Surg 2017 33 150 56 28264128 13 Liu YC Ang HP Teo EP Wound healing profiles of hyperopic-small incision lenticule extraction (SMILE) Sci Rep 2016 6 29802 27418330 14 Ganesh S Brar S Rao PA Cryopreservation of extracted corneal lenticules after small incision lenticule extraction for potential use in human subjects Cornea 2014 33 1355 62 25343698 15 Chaurasia SS Luengo Gimeno F Tan K In vivo real-time intraocular pressure variations during LASIK flap creation Invest Ophthalmol Vis Sci 2010 51 4641 45 20393112 16 Ang M Chaurasia SS Angunawela RI Femtosecond lenticule extraction (FLEx): Clinical results, interface evaluation, and intraocular pressure variation Invest Ophthalmol Vis Sci 2012 53 1414 21 22323464 17 Sun L Yao P Li M The safety and predictability of implanting autologous lenticule obtained by SMILE for hyperopia J Refract Surg 2015 31 374 79 26046703 18 Zhang T Sun Y Liu M Femtosecond laser-assisted endokeratophakia using allogeneic corneal lenticule in a rabbit model J Refract Surg 2015 31 775 82 26544566 19 Zhang MC Liu X Jin Y Lamellar keratoplasty treatment of fungal corneal ulcers with acellular porcine corneal stroma Am J Transplant 2015 15 1068 75 25762108 20 Du L Wu X Pang K Histological evaluation and biomechanical characterisation of an acellular porcine cornea scaffold Br J Ophthalmol 2011 95 410 14 20956275 21 Du L Wu X Development and characterization of a full-thickness acellular porcine cornea matrix for tissue engineering Artif Organs 2011 35 691 705 21501189 22 Dohlman TH Di Zazzo A Omoto M E-selectin mediates immune cell trafficking in corneal transplantation Transplantation 2016 100 772 80 26910325 23 Koudouna E Okumura N Okazaki Y Immune cells on the corneal endothelium of an allogeneic corneal transplantation rabbit model Invest Ophthalmol Vis Sci 2017 58 242 51 28114585 24 Angunawela RI Riau AK Chaurasia SS Refractive lenticule re-implantation after myopic ReLEx: A feasibility study of stromal restoration after refractive surgery in a rabbit model Invest Ophthalmol Vis Sci 2012 53 4975 85 22743323 25 Pradhan KR Reinstein DZ Carp GI Femtosecond laser-assisted keyhole endokeratophakia: Correction of hyperopia by implantation of an allogeneic lenticule obtained by SMILE from a myopic donor J Refract Surg 2013 29 777 82 24203809