==== Front Arthrosc TechArthrosc TechArthroscopy Techniques2212-6287Elsevier S2212-6287(18)30045-810.1016/j.eats.2018.03.009Technical NoteApplication of a Beta-Tricalcium Phosphate Graft to Minimize Bony Defect in Bone–Patella Tendon–Bone Anterior Cruciate Ligament Reconstruction Agarwalla Avinesh B.S.Puzzitiello Richard B.S.Garcia Grant H. M.D.Forsythe Brian M.D.forsythe.research@rushortho.com∗Midwest Orthopaedics at Rush, Rush University Medical Center, Chicago, Illinois, U.S.A.∗ Address correspondence to Brian Forsythe, M.D., Division of Sports Medicine, Midwest Orthopaedics at Rush, 1611 W Harrison St, Chicago, IL 60612, U.S.A. forsythe.research@rushortho.com11 6 2018 7 2018 11 6 2018 7 7 e725 e729 6 2 2018 8 3 2018 © 2018 by the Arthroscopy Association of North America. Published by Elsevier.2018Arthroscopy Association of North AmericaThis is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).Anterior cruciate ligament (ACL) reconstruction with a bone–patellar tendon–bone autograft yields good clinical outcomes. Despite appropriate clinical outcomes, the most common complaint after reconstruction with a bone–patellar tendon–bone autograft is anterior knee pain at the donor graft sites. Synthetic bone grafts, such as beta-tricalcium phosphate (β-TCP), have been previously used to fill the bony defect in fractures as well as removal of bony tumors, and have shown positive utility in improving anterior knee pain after ACL reconstruction. In this Technical Note, we describe the technique of placing a β-TCP graft in the donor graft site after bone–patellar tendon–bone ACL reconstruction. After standard arthroscopic ACL reconstruction, the β-TCP is appropriately sized with an osteotome and sagital saw before being placed into the patellar and tibial donor sites. A 0-Vicryl suture is used to suture the periosteum to secure the β-TCP graft at the donor sites. This described technique allows for appropriate sizing and secure placement of the graft to maximize bone regeneration at the donor site. ==== Body Anterior cruciate ligament (ACL) tears are one of the most prevalent traumatic knee injuries amongst athletes, occurring in nearly 69 cases per 100,000 person-years,1 and is most commonly managed with operative reconstruction to regain previous mobility. Use of the middle third of the patellar tendon is the most common autograft resulting in good clinical outcomes, and is often the first choice for young athletes.2, 3 However, patients treated with bone–patellar tendon–bone autografts have frequent complaints of long-term postoperative anterior knee pain and pain while kneeling.3, 4, 5 Without bone grafting at bone–patellar tendon–bone harvest sites, there is no evidence of bone regeneration, even at long-term time points.6 It has been hypothesized that anterior knee pain in bone–patellar tendon–bone autografts occurs because of the bony defect at the donor site or as a result of infrapatellar nerve damage during harvest of the tendon.7 In an effort to reduce anterior knee pain experienced in patients with bone–patellar tendon–bone autografts, surgeons may elect to use hamstring autografts despite evidence that hamstring autografts are associated with graft loosening and knee flexion weakness.8 Bone grafts have been used previously in reconstructive orthopaedic surgery to assist in bone realignment and stable fixation in malunion or nonunion fractures.9 Refilling the donor sites in ACL reconstruction with autologous bone obtained from coring the femoral and tibial sockets reduces the incidence of anterior knee pain10; however, this technique does not yield a sufficient amount of bone graft to fill the donor sites. Harvesting bone from other donor sites, such as the iliac crest, may provide sufficient amount of bone, but it is associated with donor site morbidity.10, 11 Synthetic materials, such as beta tri-calcium phosphate (β-TCP), possess osteoconductive properties to facilitate bone regeneration, and do not incur the risks of donor site morbidity as evidenced with cancellous autografts.12 β-TCP grafts allow for early resorption by osteoclasts and osteoblastic cell attachment to the junction of the graft surface and bone, allowing for new bone formation and direct attachment between the graft and the native bony tissue.13 β-TCP grafts have been investigated histologically and through imaging modalities, but the technique of implementing the graft during ACL reconstruction has yet to be described.13, 14, 15, 16 The aim of this Technical Note is to illustrate the application of a β-TCP graft after an ACL reconstruction for bone regeneration at autograft donor sites. Technique After confirming rupture of the ACL by magnetic resonance imaging and examination under anesthesia, a single bundle ACL reconstruction is employed. A short, vertical midline incision is made from the inferior pole of the patella to the tibial tubercle. Medial and lateral soft tissue flaps are developed, and the paratenon is then incised in line with the skin incision to expose the patellar tendon. Rectangular-shaped patella and tibial bone blocks are then harvested with the use of a sagittal saw and a curved osteotome (Fig 1), measuring 20 to 25 mm and 30 35 mm in length, respectively. Each bone block should measure approximately 10 mm in width and 10 mm in depth.Fig 1 Right knee in 10° of flexion. Gross image of the distal insertion of the patellar tendon into the tibial tubercle. An osteotome is used to remove the bone blocks for the bone–patellar tendon–bone autograft that is to be used in the anterior cruciate ligament reconstruction portion of the procedure. After standard ACL reconstruction of the graft, the knee remains in 10° of flexion, and the patellar and tibial donor graft sites are measured. As demonstrated in Video 1, wedges of a 10-mm-thick β-TCP graft (Osferion; Arthrex, Naples, FL) can be initially placed within the bony defects to approximate how much graft must be removed for a proper fit (Fig 2). The β-TCP is then cut with a sagittal saw for appropriate sizing within the bony defect (Video 1 and Fig 3). Cancellous bone that was collected from the tibia and femoral tunnels can be placed along the base of the defect creating a flat surface for the graft to rest upon. After appropriate sizing of the β-TCP graft, it is placed into the bony deficit. As depicted in Video 1, the graft is gently tamped into position for a press fit with an impactor and mallet (Fig 4). After placement of the β-TCP graft, the remaining cancellous bone from the bony tunnels can be placed on top of the graft. The periosteum is then closed over the top of the graft with a 0-Vicryl absorbable suture (Video 1 and Fig 5). The described process is repeated for the tibial donor site. After fixation of the graft, the paratenon (Fig 6), subcutaneous tissue, and dermis are closed in a standard fashion. After operative repair, the patient is then immobilized with a knee brace and can be discharged home the same day. Common pearls and pitfalls of applying a β-TCP graft are described in Table 1.Fig 2 Right knee in 10° of flexion. Gross image of the proximal insertion of the patellar tendon into the distal pole of the patella. An unshaped wedge of 10-mm-thick beta-tricalcium phosphate (β-TCP) is placed within the bony defect to approximate the amount of graft that must be removed to allow for a proper fit. Fig 3 (A) Right knee in 10° of flexion. Gross image of the beta-tricalcium phosphate (β-TCP) being trimmed in length for proper sizing within the bony defect. (B) Right knee in 10° of flexion. Gross image of the β-TCP being trimmed in width for proper sizing within the bony defect. Fig 4 Right knee in 10° of flexion. Gross image of the proximal insertion of the patellar tendon into the distal pole of the patella. The beta-tricalcium phosphate (β-TCP) graft is impacted into the bony defect with a mallet and tamp to create a press fit. Fig 5 Right knee in 10° of flexion. Gross image of the proximal insertion of the patellar tendon into the distal pole of the patella. A 0-Vicryl absorbable suture is used to close the periosteum over top of the graft, thus securing it in place. (β-TCP, beta-tricalcium phosphate.) Fig 6 Right knee in 10° of flexion. Gross image of the proximal insertion of the patellar tendon into the distal pole of the patella. A 0-Vicryl absorbable suture is used to close the paratenon over top of the graft after closure of the periosteum. Table 1 Pearls and Pitfalls of β-TCP Application Pearls Pitfalls Use of sagittal saw allows accurate sizing and shaping of the graft Failure to properly shape the graft may result in treatment failure Placement of cancellous bone on the β-TCP graft may facilitate graft incorporation Inappropriate fixation of the graft within the donor site may lead to patient discomfort or graft failure An absorbable suture prevents the possibility of a foreign body reaction as it may occur with a nonabsorbable suture β-TCP, beta-tricalcium phosphate. Discussion Bone–patellar tendon–bone autografts remain the most commonly used autograft in ACL reconstruction, especially in young athletes.2, 3 Outcomes after bone–patellar tendon–bone autografts are generally favorable as patients report high satisfaction, earlier return to play, and low failure rates.3, 5, 17 Despite the satisfactory outcomes after bone–patellar tendon–bone ACL reconstruction, the most common complaint, even at long-term time points, remains postoperative anterior knee pain.3, 4, 5, 18 Nearly 40% of patients experience pain while walking on a hard ground and had persistent numbness overlying the knee 10 years postoperatively.19 The use of biological supplementation can potentially reduce anterior knee pain at donor sites. The use of bony autografts or protein-rich plasma to fill the defect at donor sites has demonstrated reduced anterior knee pain and improved functionality postoperatively.10, 20 Although the mechanism of plasma-rich protein remains debated, autologous bone grafts offer osteoconductivity that enables bone growth at the site of deficit. However, in ACL reconstruction, the amount of cancellous bone that is obtained is generally not sufficient to fill the defect at both the tibia and patella. Synthetic grafts, such as calcium hydroxyapatite and β-TCP, offer osteoconductive properties similar to bony autografts. These grafts are advantageous because they reduce the morbidity associated with bony autografts and remove the variable of bone quality from determining outcomes of filling the defect. In a prospective case series using β-TCP grafts within the patellar and tibial donor sites in ACL reconstruction, all patients were able to kneel, walk on hard ground, and perform agility exercises without pain, whereas 1 patient noted mild discomfort with walking on hard ground.14 Calcium hydroxyapatite and β-TCP have been used previously for filling the bony defect that remains in fractures or after removal of bony tumors.15 β-TCP has shown to allow for ample bone formation and was absorbed over time, whereas calcium hydroxyapatite was not absorbed and even hindered the formation of new bone.21 Nearly 2 years after placement of the β-TCP graft at the site of bony tumor resection, histological examination demonstrated that lamellar bone replaced the graft and there was no remaining osteoclastic or osteoblastic activity.16 In a case series of 75 patients who received calcium hydroxyapatite after removal of a bony tumor, 2 patients experienced pathological fractures at the site of the graft and 2 additional patients reported persistent pain at the graft site.22 Conversely, in a series of 53 patients receiving β-TCP grafts after the removal of a bony tumor, there were no instances of pathological fractures.23 The superiority of β-TCP in bone regeneration is hypothesized to be due to the presence of microfibrils within the β-TCP graft that allows for early resorption by osteoclasts, neovasculation, and osteoblastic activity, which allows for replacement of the graft with de novo bone.16 Histological evaluation of the implanted β-TCP graft demonstrates that newly formed bone is directly connected between the β-TCP graft and pre-existing native bone.15, 16 Although the use of β-TCP confers clinical benefit in ACL reconstruction, the procedure of placing the graft into donor sites is not without risks. Creating a graft that is too large may result in cosmetic deformity or discomfort with kneeling or ambulation. On the other hand, shaping a graft that is too small may reduce the efficacy of the β-TCP graft as movement may dislodge the graft within the donor site, thus preventing replacement of the graft with de novo bony tissue. In addition, failure to adequately secure the graft into the donor site with the periosteum may lead to graft slippage or failure in the postoperative period. Advantages and disadvantages of using this technique are illustrated in Table 2.Table 2 Advantages and Disadvantages of β-TCP Application Advantages Disadvantages No donor-site morbidity Increased operative time Greater graft availability Added cost to patient Ease of sizing the graft to conform to the donor site Improved donor site discomfort in bone–patellar tendon–bone donor sites Although there are some risks associated with the use of a β-TCP, it assists in bone regeneration at donor sites while improving patient outcomes and minimizing complications experienced by patients after bone–patellar tendon–bone autograft ACL reconstruction, such as quadriceps weakness, flexion contracture, and patellofemoral pain.14, 24 This simple technique that is performed at the end of bone–patellar tendon–bone autograft ACL reconstruction can reduce persistent anterior knee pain and improve patient satisfaction. Supplementary Data Video 1 Technique for beta-tricalcium phosphate grafting of the bone–patellar tendon–bone anterior cruciate ligament (ACL) autograft harvest site of the right knee. The patient is lying supine with the right leg in 10° of flexion. The bone–patellar tendon–bone autograft is harvested in a standard fashion. After completion of the ACL reconstruction procedure, wedges of a 10-mm-thick beta-tricalcium phosphate graft are cut to the size of the bony defects with a handheld sagittal saw. The bony defects are packed with a thin layer of cancellous bone from the ACL reconstruction procedure, to create a flat base for the graft to rest upon. The graft is gently tamped into place with a mallet and an impactor to create a press fit. A 0-Vicryl absorbable suture is used to close the periosteum and the paratenon overtop the graft to secure it in place. The subcutaneous tissue and the dermis are then sequentially closed to complete the procedure. ICMJE author disclosure forms The author reports the following potential conflicts of interest or sources of funding: B.F. receives personal fee from Elsevier, Arthrex, Jace Medical, and Styker; and grants from Smith & Nephew and Ossur. Full ICMJE author disclosure forms are available for this article online, as supplementary material. ==== Refs References 1 Sanders T.L. Maradit Kremers H. Bryan A.J. Incidence of anterior cruciate ligament tears and reconstruction: A 21-year population-based study Am J Sports Med 44 2016 1502 1507 26920430 2 Shelton W.R. Fagan B.C. Autografts commonly used in anterior cruciate ligament reconstruction J Am Acad Orthop Surg 19 2011 259 264 21536625 3 Kane P.W. Wascher J. Dodson C.C. Hammoud S. Cohen S.B. Ciccotti M.G. Anterior cruciate ligament reconstruction with bone–patellar tendon–bone autograft versus allograft in skeletally mature patients aged 25 years or younger Knee Surg Sports Traumatol Arthrosc 24 2016 3627 3633 27349433 4 Kartus J. Magnusson L. Stener S. Brandsson S. Eriksson B.I. Karlsson J. Complications following arthroscopic anterior cruciate ligament reconstruction. A 2-5-year follow-up of 604 patients with special emphasis on anterior knee pain Knee Surg Sports Traumatol Arthrosc 7 1999 2 8 10024955 5 Poehling-Monaghan K.L. Salem H. Ross K.E. Long-term outcomes in anterior cruciate ligament reconstruction: A systematic review of patellar tendon versus hamstring autografts Orthop J Sports Med 5 2017 2325967117709735 6 Ferrari J.D. Bach B.R. Jr. Bone graft procurement for patellar defect grafting in anterior cruciate ligament reconstruction Arthroscopy 14 1998 543 545 9681553 7 Kartus J. Stener S. Lindahl S. Engstrom B. Eriksson B.I. Karlsson J. Factors affecting donor-site morbidity after anterior cruciate ligament reconstruction using bone–patellar tendon–bone autografts Knee Surg Sports Traumatol Arthrosc 5 1997 222 228 9430571 8 Koh E. Oe K. Takemura S. Iida H. Anterior cruciate ligament reconstruction using a bone–patellar tendon–bone autograft to avoid harvest-site morbidity in knee arthroscopy Arthrosc Tech 4 2015 e179 e184 26052497 9 Nauth A. Lane J. Watson J.T. Giannoudis P. Bone graft substitution and augmentation J Orthop Trauma 29 suppl 12 2015 S34 S38 26584264 10 Tsuda E. Okamura Y. Ishibashi Y. Otsuka H. Toh S. Techniques for reducing anterior knee symptoms after anterior cruciate ligament reconstruction using a bone–patellar tendon–bone autograft Am J Sports Med 29 2001 450 456 11476385 11 Arrington E.D. Smith W.J. Chambers H.G. Bucknell A.L. Davino N.A. Complications of iliac crest bone graft harvesting Clin Orthop Relat Res 329 1996 300 309 12 Bauer T.W. Muschler G.F. Bone graft materials. An overview of the basic science Clin Orthop Relat Res 371 2000 10 27 13 Gaasbeek R.D. Toonen H.G. van Heerwaarden R.J. Buma P. Mechanism of bone incorporation of beta-TCP bone substitute in open wedge tibial osteotomy in patients Biomaterials 26 2005 6713 6719 15950278 14 Higuchi H. Kobayashi A. Ikeda K. Hatayama K. Yanagisawa S. Kato K. Efficacy of beta-tricalcium phosphate graft into the bone defects after bone–patellar tendon–bone anterior cruciate ligament reconstruction J Knee Surg 30 2017 467 473 27680889 15 Ogose A. Hotta T. Kawashima H. Comparison of hydroxyapatite and beta tricalcium phosphate as bone substitutes after excision of bone tumors J Biomed Mater Res 72B 2005 94 101 16 Ogose A. Kondo N. Umezu H. Histological assessment in grafts of highly purified beta-tricalcium phosphate (OSferion) in human bones Biomaterials 27 2006 1542 1549 16165205 17 Nwachukwu B.U. Voleti P.B. Berkanish P. Return to play and patient satisfaction after ACL reconstruction: Study with minimum 2-year follow-up J Bone Joint Surg Am 99 2017 720 725 28463915 18 Kartus J. Movin T. Karlsson J. Donor-site morbidity and anterior knee problems after anterior cruciate ligament reconstruction using autografts Arthroscopy 17 2001 971 980 11694930 19 Ahn J.H. Kim J.G. Wang J.H. Jung C.H. Lim H.C. Long-term results of anterior cruciate ligament reconstruction using bone–patellar tendon–bone: An analysis of the factors affecting the development of osteoarthritis Arthroscopy 28 2012 1114 1123 22421565 20 Cervellin M. de Girolamo L. Bait C. Denti M. Volpi P. Autologous platelet-rich plasma gel to reduce donor-site morbidity after patellar tendon graft harvesting for anterior cruciate ligament reconstruction: A randomized, controlled clinical study Knee Surg Sports Traumatol Arthrosc 20 2012 114 120 21678095 21 Oyake Y. Beppu M. Ishii S. Takagi M. Takashi M. Intramedullary anchoring strength of titanium rod with mixed beta-tricalcium phosphate and fibrin adhesive J Orthop Sci 7 2002 123 130 11819144 22 Yamamoto T. Onga T. Marui T. Mizuno K. Use of hydroxyapatite to fill cavities after excision of benign bone tumours. Clinical results J Bone Joint Surg Br 82 2000 1117 1120 11132269 23 Hirata M. Murata H. Takeshita H. Sakabe T. Tsuji Y. Kubo T. Use of purified beta-tricalcium phosphate for filling defects after curettage of benign bone tumours Int Orthop 30 2006 510 513 16736145 24 Sachs R.A. Daniel D.M. Stone M.L. Garfein R.F. Patellofemoral problems after anterior cruciate ligament reconstruction Am J Sports Med 17 1989 760 765 2624287