==== Front J Saudi Heart AssocJ Saudi Heart AssocJournal of the Saudi Heart Association1016-73152212-5043Elsevier S1016-7315(17)30164-110.1016/j.jsha.2018.05.002ArticleEvasion maneuver for transseptal approach during cryoballoon pulmonary vein isolation Blockhaus Christian christianblockhaus@web.deab⁎Waibler Hans-Peter abGülker Jan-Erik abKlues Heinrich abBufe Alexander abcShin Dong-In aba Department of Cardiology, Heart Centre Niederrhein, Helios Clinics Krefeld, Krefeld, Germanyb Institute for Heart and Circulation Research, University of Cologne, Cologne, Germanyc University Witten/Herdecke, Witten, Germany⁎ Corresponding author at: Department of Cardiology, Heart Centre Niederrhein, Helios Clinics, Lutherplatz 40, 47805 Krefeld, Germany. christianblockhaus@web.de01 6 2018 10 2018 01 6 2018 30 4 301 304 18 12 2017 11 4 2018 14 5 2018 © 2018 The Authors2018This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).Purpose Pulmonary vein isolation (PVI) is a cornerstone therapy in patients with symptomatic atrial fibrillation. One current method is performing a PVI using a cryoballoon (CB). The CB is inserted into the left atrium via a steerable sheath. However, at times, passing of the interatrial septum by the sheath is hindered, e.g., due to septal fibrosis. Here we report our experience with an evasion maneuver to facilitate this approach using a 6F multipolar and steerable coronary Sinus catheter (CS) for predilatation of the interatrial septum. Methods and results We report 10 patients undergoing a CB-PVI, where the investigator experienced difficulties in passing the interatrial septum with the CB sheath. In these cases, after three conventional abortive attempts, we predilated the transseptal puncture site using both the CS catheter and the dilatator of the CB sheath. Thereafter access of the CB sheath to the left atrium could be achieved instantly and without further resistance. Conclusion We report a safe and feasible maneuver to facilitate transseptal access with the CB steerable sheath in cases complicated by excessive interatrial resistance. Keywords Coronary sinus catheterCryoballoonPulmonary vein isolationTransseptal approachDisclosure: Authors have nothing to disclose with regard to commercial support. ==== Body Introduction Atrial fibrillation (AF) is the most common sustained atrial arrhythmia with increasing incidence and prevalence [1], [2]. Pulmonary vein isolation (PVI) is a cornerstone therapy in drug resistant AF. Several studies proved the superiority of PVI versus medical therapy in symptomatic patients [3], [4]. As an alternative to radiofrequency (RF) ablation, PVI with cryoballoon (CB; Medtronic, Minneapolis, MN, USA) was established several years ago. Recently, a study reported a noninferiority of CB versus RF ablation [5]. During PVI with CB a special unidirectional and steerable sheath (FlexCath Advance Steerable Sheath; Medtronic) is introduced in the left atrium (LA). Its inner diameter is 12F and the outer diameter is 15F. In our clinical experience we noticed in several cases that passing the interatrial septum (IAS) with the CB sheath was difficult due to stiff or thickened tissue. We report on our experience of a simple evasion maneuver during transseptal access with the CB sheath using a 6F multipolar, steerable diagnostic catheter as a predilatator in conjunction with the dilatator of the CB sheath. Material and methods We report 10 patients who were treated by PVI using a CB catheter. PVI was performed under deep sedation using midazolam and propofol. After transseptal puncture was achieved with a fixed, 8F sheath (LAMP45; SJM, St. Paul, MN, USA) using a BRK needle (SJM), a stiff wire (Amplatz super stiff; Boston Scientific, Marlborough, MA, USA) was placed as a guiding wire into the left superior pulmonary vein (LSPV). Then, the fixed 8F sheath was exchanged for the CB sheath over the wire. In case of an unsuccessful transseptal passage despite repeated attempts (pushing and drawing back of the 12F sheath, Fig. 1A), the sheath was placed in the right atrium a short distance from the IAS whereas the stiff wire was left in the LSPV. Subsequently, the transseptal puncture site was passed with the 6F CS catheter (Inquiry; SJM) which was also placed in the LSPV (Fig. 1B). We dilated the puncture site by gently pushing the dilatator of the CB sheath towards the LA with the CS catheter still being placed in the LA (Fig. 1C). Afterwards we withdrew the CB sheath again and removed the CS catheter from the LA into its original position. Finally, the CB sheath passed the transseptal puncture site into the LA (Fig. 1D). Fig. 2A shows a picture of the CB sheath and a closer look at its tip close to the virtual IAS (dashed line, Fig. 2B). The reported evasion maneuver is schematically shown in Fig. 2C with the CB sheath near this virtual IAS and the 6F CS catheter already placed in the LA.Figure 1 (A) Unsuccessful transseptal passage with the steerable sheath; (B) coronary sinus catheter placed in LSPV; (C) dilatation of the puncture site; (D) CB sheath placed in LA. Pictures taken in LAO 40° view. CB = cryoballoon; CS = coronary Sinus; LA = left atrium; LAO = left anterior oblique; LSPV = left superior pulmonary vein; RVA = right ventricular apex. Figure 2 (A) CB steerable sheath; (B) schema of the 12F sheath (15F outer diameter) close to the interatrial septum (dashed line); (C) schema of 12F sheath + 6F CS catheter close to the interatrial septum (dashed line). Results In all reported patients we initially failed to pass the atrial septum with the CB sheath three times. Predilatation of the interatrial puncture site by the 6F CS catheter plus the 12F dilatator of the CB sheath could be performed in all patients with no complications. After this evasion maneuver, access with the 12F CB sheath to LA could be achieved unhampered in all cases. Discussion We report on our experience in CB PVI where transseptal access with the 12F CB sheath (15F outer lumen) was difficult. Even for experienced investigators transseptal approach for ablation of LA arrhythmias remains challenging due to, for example, anatomic obstacles. In 2010 Cappato et al [6] published a worldwide survey with an incidence of pericardial tamponade—which of course may not only be caused by transseptal puncture but also by the ablation procedure—of 1.3% in >20,000 catheter ablation procedures. Reasons for difficulties during an LA approach may be a floppy septum, a thickened atrial septum after preceding transseptal puncture, or, for example, a lipomatous atrial septal hypertrophy [7]. In patients with congenital heart disease who underwent surgery the incidence of arrhythmias is even higher with a challenging atrial approach. Uhm et al [8] recently published a work with tips on how to perform transconduit and transbaffle puncture in those patients. Marcus et al [9] showed that repeated transseptal puncture is more difficult to achieve due to interatrial scarring. Of note, none of our reported patients had undergone transseptal puncture before. Several techniques to improve the safety and success of transseptal puncture have been developed [10], [11]. Furthermore, guiding of transseptal puncture in the context of a complex atrial septal anatomy by intracardiac echocardiography has been described to be helpful [12], [13]. In our clinic we usually do not use steerable sheaths or intracardiac echocardiography for transseptal puncture. By using a predilatation maneuver we successfully gained access to the LA for the large CB sheath of 12F (with an outer diameter of 15F) without any further resistance and complications. Of note, the initial transseptal puncture with the 8F sheath was mostly unproblematic. The maneuver is easy to conduct with the employed material and investigators were not obliged to perform further unsuccessful attempts of transseptal passage with the CB sheath. As a limitation of our report, we have no data regarding occurrence of relevant and persistent iatrogenic atrial septal defect (ASD) caused by this predilatation approach as our patients did not undergo a follow-up transesophageal echocardiography. However, none of our patients presenting for redo ablation (irrespective of this maneuver) showed a persistent atrial defect in transesophageal echocardiography. Recently, Linhart et al [14] reported a relatively high incidence of ASD after CB PVI but without increased clinical complication. This is consistent with other groups’ findings concerning persistent ASD after CB or RF PVI [15], [16], [17]. We report on an evasion maneuver to facilitate transseptal access with the 12F CB sheath (15F outer lumen) in patients undergoing PVI. Peer review under responsibility of King Saud University. ==== Refs References 1 Bai Y. Wang Y.L. Shantsila A. Lip G.Y.H. The global burden of atrial fibrillation and stroke: a systematic review of the clinical epidemiology of atrial fibrillation in Asia Chest 152 4 2017 810 820 28427968 2 Ceornodolea A.D. Bal R. Severens J.L. Epidemiology and management of atrial fibrillation and stroke: review of data from four European countries Stroke Res Treat 2017 2017 8593207 28634569 3 Piccini J.P. Lopes R.D. Kong M.H. Hasselblad V. Jackson K. Al-Khatib S.M. Pulmonary vein isolation for the maintenance of sinus rhythm in patients with atrial fibrillation: a meta-analysis of randomized, controlled trials Circ Arrhythm Electrophysiol 2 2009 626 633 20009077 4 Pappone C. Rosanio S. Augello G. Gallus G. Vicedomini G. Mazzone P. Mortality, morbidity, and quality of life after circumferential pulmonary vein ablation for atrial fibrillation: outcomes from a controlled nonrandomized long-term study J Am Coll Cardiol 42 2003 185 197 12875749 5 Kuck K.H. Brugada J. Furnkranz A. Metzner A. Ouyang F. Chun K.R. Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation New Engl J Med 374 2016 2235 2245 27042964 6 Cappato R. Calkins H. Chen S.A. Davies W. Iesaka Y. Kalman J. Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation Circ Arrhythm Electrophysiol 3 2010 32 38 19995881 7 Laura D.M. Donnino R. Kim E.E. Benenstein R. Freedberg R.S. Saric M. Lipomatous atrial septal hypertrophy: a review of its anatomy, pathophysiology, multimodality imaging, and relevance to percutaneous interventions J Am Soc Echocardiogr 29 2016 717 723 27288088 8 Uhm J.S. Kim N.K. Kim T.H. Joung B. Pak H.N. Lee M.H. How to perform transconduit and transbaffle puncture in patients who have previously undergone the Fontan or Mustard operation Heart Rhythm 15 2018 145 150 28716702 9 Marcus G.M. Ren X. Tseng Z.H. Badhwar N. Lee B.K. Lee R.J. Repeat transseptal catheterization after ablation for atrial fibrillation J Cardiovasc Electrophysiol 18 2007 55 59 17081207 10 O'Brien B. Zafar H. De Freitas S. Sharif F. Transseptal puncture—review of anatomy, techniques, complications and challenges Int J Cardiol 233 2017 12 22 28202256 11 Aksu T. Guler T.E. Yalin K. Golcuk S.E. Ozcan K.S. Guler N. A novel deep inspiration maneuver for difficult transseptal puncture Am J Cardiol 119 2017 428 433 27884419 12 Liu C.F. The evolving utility of intracardiac echocardiography in cardiac procedures J Atr Fibrillation 6 2014 1055 27957066 13 Ruisi C.P. Brysiewicz N. Asnes J.D. Sugeng L. Marieb M. Clancy J. Use of intracardiac echocardiography during atrial fibrillation ablation Pacing Clin Electrophysiol 36 2013 781 788 23305194 14 Linhart M. Werner J.T. Stockigt F. Kohlmann A.T. Lodde P.C. Linneborn L.P.T. High rate of persistent iatrogenic atrial septal defect after single transseptal puncture for cryoballoon pulmonary vein isolation J Interv Card Electrophysiol 2018 [Epub ahead of print] 15 Watanabe T. Miyazaki S. Kajiyama T. Ichijo S. Takagi T. Igarashi M. Persistence of an iatrogenic atrial septal defect after a second-generation cryoballoon ablation of atrial fibrillation Heart Vessels 2018 [Epub ahead of print] 16 Davies A. Gunaruwan P. Collins N. Barlow M. Jackson N. Leitch J. Persistent iatrogenic atrial septal defects after pulmonary vein isolation: long-term follow-up with contrast transesophageal echocardiography J Interv Card Electrophysiol 48 2017 99 103 27683061 17 Mugnai G. Sieira J. Ciconte G. Hervas M.S. Irfan G. Saitoh Y. One year incidence of atrial septal defect after PV isolation: a comparison between conventional radiofrequency and cryoballoon ablation Pacing Clin Electrophysiol 38 2015 1049 1057 25974316