==== Front World J Surg World J Surg World Journal of Surgery 0364-2313 1432-2323 Springer International Publishing Cham 37005926 7000 10.1007/s00268-023-07000-w Original Scientific Report A Prospective Study of Electromyographic Amplitude Changes During Intraoperative Neural Monitoring for Open Thyroidectomy Lian Tony tlia0798@uni.sydney.edu.au 12Tony Lian is a final-year medical student at Northern Clinical School, Royal North Shore Hospital, and Sydney Medical School. He has completed a Bachelor of Science (Advanced) from The University of Sydney. Tony hopes to pursue a career in surgery and dedicate his career to evidence-based clinical practice and research to improve patient outcomes. His Twitter handle is @TonyLianAU. Leong David 2 Ng Karl 13 Bajenov Sonya 4 Sywak Mark 12 1 grid.1013.3 0000 0004 1936 834X Northern Clinical School, Sydney Medical School, Faculty of Medicine and Health, University of Sydney, Sydney, NSW 2006 Australia 2 grid.482157.d 0000 0004 0466 4031 Department of Endocrine Surgery, Royal North Shore Hospital, Northern Sydney Local Health District, St Leonards, NSW 2065 Australia 3 grid.482157.d 0000 0004 0466 4031 Department of Neurology, Royal North Shore Hospital, Northern Sydney Local Health District, St Leonards, NSW 2065 Australia 4 grid.482157.d 0000 0004 0466 4031 Department of Anaesthesia and Pain Management, Royal North Shore Hospital, Northern Sydney Local Health District, St Leonards, NSW 2065 Australia 1 4 2023 1 4 2023 2023 47 8 19711977 18 3 2023 © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. Background Intraoperative nerve monitoring (IONM) of the vagus and recurrent laryngeal nerve (RLN) enables prediction of postoperative nerve function. The underlying mechanism for loss of signal (LOS) in a visually intact nerve is poorly understood. The correlation of intraoperative electromyographic amplitude changes (EMG) with surgical manoeuvres could help identify mechanisms of LOS during conventional thyroidectomy. Methods A prospective study of consecutive patients undergoing thyroidectomy was performed with intermittent IONM using the NIM Vital nerve monitoring system. The ipsilateral vagus and RLN was stimulated, and vagus nerve signal amplitude recorded at five time points during thyroidectomy (baseline, after mobilisation of superior pole, medialisation of the thyroid lobe, before release at Ligament of Berry, end of case). RLN signal amplitude was recorded at two time points; after medialisation of the thyroid lobe (R1), and end of case (R2). Results A total of 100 consecutive patients undergoing thyroidectomy were studied with 126 RLN at risk. The overall rate of LOS was 4.0%. Cases without LOS demonstrated a highly significant vagus nerve median percentage amplitude drop at medialisation of the thyroid lobe (− 17.9 ± 53.1%, P < 0.001), and end of case (− 16.0 ± 47.2%, P < 0.001) compared to baseline. RLN had no significant amplitude drop at R2 compared to R1 (P = 0.207). Conclusions A significant reduction in vagus nerve EMG amplitude at medialisation of the thyroid and the end of case compared to baseline indicates that stretch injury or traction forces during thyroid mobilisation are the most likely mechanism of RLN impairment during conventional thyroidectomy. University of Sydney Open Access funding enabled and organized by CAUL and its Member Institutions issue-copyright-statement© Société Internationale de Chirurgie 2023 ==== Body pmcIntroduction Routine intraoperative nerve monitoring (IONM) is widely used internationally in thyroid surgery; enabling prediction of postoperative nerve function and avoiding bilateral recurrent laryngeal nerve (RLN) palsy [1]. IONM is an adjunct to the gold standard direct visualisation and preservation of the RLN. RLN palsy, a serious complication of surgery, can cause dysphonia, dysphagia and potential airway obstruction [2]. Loss of signal (LOS), when detected with IONM, represents neurophysiological changes to the anatomically intact nerve and is a predictor for postoperative vocal cord dysfunction, allowing reconsideration of the surgical approach to staged thyroidectomy and avoiding bilateral nerve palsy [3, 4]. Type 1 LOS is defined as segmental injury, where electromyography (EMG) signal is preserved distal to the point of injury, whereas Type 2 LOS is a global injury where EMG signal is not detectable at the vagus and at the recurrent laryngeal nerve in its extralaryngeal portion, however, the intralaryngeal portion of the RLN cannot be tested [5]. INMSG guidelines have utilised an EMG cut-off of 100 μV or less to define LOS [6]. Division and permanent injury of the RLN is uncommon in experienced hands; however, LOS in a visually intact nerve occurs in up to 2–15% of thyroidectomy procedures [7–9]. The underlying mechanism for LOS in a visually intact nerve is poorly understood [8, 9]. It is postulated that a visually intact RLN with LOS intraoperatively could be a result of traction, compression at the intralaryngeal portion, or thermal injury [10]. The evaluation of IONM amplitude changes may help to identify mechanisms of LOS during conventional thyroidectomy. The aim was to conduct a prospective study using nerve integrity monitoring to measure IONM amplitude changes associated with surgical manoeuvres in patients undergoing conventional thyroidectomy and to better understand the pathophysiological changes to RLN function during thyroidectomy. Material and methods A prospective study of 100 consecutive patients undergoing conventional thyroidectomy cases was performed with IONM using the NIM Vital nerve monitoring system (Medtronic TM) and TriVantage endotracheal EMG tube. This was conducted by a single surgeon and anaesthetist with a standardised surgical approach for every patient. Patients were excluded if there was RLN palsy on preoperative laryngoscopy, < 18 years of age or re-operative thyroidectomy procedures. During intubation, the anaesthetist confirmed correct endotracheal tube positioning under direct vision. The event stimulus threshold was set at 100 uV, and electrode stimulation set at 1 mA. 200 ug of Sugammadex was administered intravenously in all subjects after intubation at least 10 min prior to commencement of surgery, to reverse neuromuscular blockade and prevent confounding due to paralysis. The ipsilateral vagus nerve was stimulated, and vagus nerve signal amplitude recorded at five time points during thyroidectomy (baseline, after mobilisation of superior pole, medialisation of the thyroid lobe, before release at Ligament of Berry, and at end of case). Five manoeuvres were completed sequentially for each thyroid lobe, with the vagus nerve stimulated following each manoeuvre. After identification and stimulation of the ipsilateral vagus nerve as a baseline reading (V1), the thyroid isthmus was divided. Subsequent to this, the superior pole was mobilised and another vagus nerve reading performed (superior pole mobilised). The inferior pole of the thyroid was then mobilised. Following this, anteromedial rotation of the gland and another vagus nerve reading was performed (medialisation). The RLN was then identified and stimulated within 2 cm of the Ligament of Berry (R1). After complete dissection of the RLN, just prior to release at the Ligament of Berry, another vagus nerve reading was performed (before release of RLN). Following removal of the thyroid gland, the vagus nerve and RLN were stimulated with the larynx in its anatomical location to mark end of case (V2) and (R2), respectively. Stimulation of the RLN was within 2 cm of the Ligament of Berry. Stimulation of the vagus nerve was conducted distal to the superior laryngeal nerve, at the level of the cricoid cartilage within the carotid sheath. In all cases of type 2 loss of signal, the surgeon waited for twenty minutes to observe for any intraoperative nerve recovery. A deidentified prospective database was maintained on the studied patients. All patients had preoperative and postoperative fibreoptic laryngoscopy to assess vocal cord function. Statistical analysis Statistical analysis was conducted using GraphPad Prism 9 (Version 9.3.1). Descriptive statistics are described using mean and standard deviation or median and interquartile range depending on distribution. Wilcoxon sign rank testing was performed on electromyography absolute amplitudes and relative percentage drop from baseline. Kruskal–Wallis test and post hoc Dunn’s multiple comparisons tests were used to compare multiple categories. Logistic univariable and multivariable regression was performed to assess for patient or surgical predictors of LOS cases. Statistical power calculations were conducted on Stata (Version 17.0). Cohen’s effect size estimates demonstrated that if the true difference in the mean response of matched pairs is 0.2, to achieve adequate statistical power of 90% with a type I error probability of 0.05, a sample size of only 26 pairs of patients is required, indicating the study was adequately powered. Results A total of 100 consecutive patients undergoing thyroidectomy (26 total thyroidectomy, 74 hemithyroidectomy) were studied with 126 RLN at risk. Patient factors and surgical characteristics are summarised in Table 1. The mean patient age was 49, and the median lobe volume was 20.0 ml (Table 1). The overall rate of loss of signal (LOS) was 4.0%, with no permanent RLN injuries. There were 2 nerves with type 1 LOS, 3 nerves with type 2 LOS and 121 functionally intact nerves. All patients with intraoperative LOS were confirmed to have vocal cord palsy postoperatively which resolved in all patients at a median of 30 days post-surgery. In all patients, there was appropriate electrode placement, normal preoperative laryngoscopy and successful intraoperative identification and stimulation of the vagus nerve.Table 1 Descriptive data for 100 consecutive patients with 126 nerves at risk Variables (n = 100) Age (years)a 49 ± 17 BMI (kg/m2)a 25.4 ± 6.3 Lobe volume (ml)b 20.0 ± 21.6 Largest nodule size (mm)b 25.0 ± 19.7 Duration of surgery (mins)b 54 ± 14 Global LOS 5 Indication for surgery Completion thyroidectomy 10 Graves’ disease 6 Thyroiditis 6 Malignancy or risk of malignancy 17 Single nodule 34 Multinodular goitre 27 aMean ± SD bMedian ± IQR Electromyography (EMG) amplitude measurements There was a highly significant drop in vagus nerve electromyography amplitude at medialisation of the thyroid lobe (662 ± 542 mA, P < 0.001) and before release at the Ligament of Berry (683 ± 581 mA, P < 0.001) compared to baseline (810 ± 488 mA). There was also significant reduction compared to baseline at the conclusion of the procedure once all traction had been released (658 ± 578 mA, P < 0.001) (Table 2). There was also a highly significant vagus nerve relative percentage amplitude drop at medialisation of the thyroid lobe (− 22.1 ± 54.5%, P < 0.001), before release at the Ligament of Berry (− 29.8 ± 67.1%, P < 0.001) and at the end of case (− 17.7 ± 51.8%, P < 0.001) compared to baseline (Table 2). Furthermore, in the group without type 1 or type 2 LOS, there was a highly significant vagus nerve percentage amplitude drop at medialisation of the thyroid lobe (− 17.9 ± 53.1%, P < 0.001), before release at the Ligament of Berry (− 20.7 ± 61.7%, P < 0.001) and at the end of case (− 16.0 ± 47.2%, P < 0.001) compared to baseline. All cases of type 2 LOS were associated with a preceding 28.5% median amplitude drop from baseline and occurred exclusively during medialisation of the thyroid lobe. There were no cases of LOS which recovered intraoperatively.Table 2 Median electromyography amplitudes and percentage changes from baseline of IONM vagus nerve stimulation between time points (superior pole, medialisation, before RLN release and at end of procedure) during thyroidectomy (n = 100) Time points during surgery EMG vagus amplitude median (IQR) (mA) 95% CI median amplitude Pa EMG median percentage change from baseline (IQR) (%) 95% CI median amplitude percentage change Pb Baseline (V1) 810 (488) (701, 900) Ref Ref Ref Ref Superior pole mobilised 774 (511) (650, 820) 0.011 − 5.2 (27.6) (− 10.21, 0.00) 0.015 Medialisation 662 (542) (575, 780) < 0.001 − 22.1 (54.5) (− 30.93, − 13.92) < 0.001 Before release of RLN at Ligament of Berry 683 (581) (564, 804) < 0.001 − 29.8 (67.1) (− 38.10, − 18.21) < 0.001 End of procedure (V2) 658 (578) (562, 760) < 0.001 − 17.7 (51.8) (− 27.94, − 9.41) < 0.001 aP value of median electromyography change from baseline bP value of median electromyography percentage change from baseline There was no significant difference between initial baseline (V1) vagus nerve amplitude recording between right (M = 811 ± 338 mA) and left thyroid lobes (M = 934 ± 575 mA) (P = 0.3942) in patients undergoing total thyroidectomy. Similarly, there was no significant difference in amplitude measurements on stimulation of the recurrent laryngeal nerve between R1 (M = 1007 ± 623 mA) and R2 in all patients (M = 1061 ± 589 mA, P = 0.229) (Table 3). Furthermore, in the group without type 1 or type 2 LOS, there was no significant difference between R1 (M = 1042 ± 609 mA) and R2 (M = 1077 ± 567 mA, P = 0.207) on stimulation of the recurrent laryngeal nerve.Table 3 Median electromyography amplitudes of IONM recurrent laryngeal nerve stimulation after medialisation (R1) and after conclusion of the case (R2) during thyroidectomy (n = 100) Time points during surgery EMG amplitude median (IQR) 95% CI R1 919 (884) (670, 1100) R2 979 (742) (860, 1100) There was a significant difference in vagus nerve EMG median amplitude compared to baseline within the four remaining timepoints (after mobilisation of superior pole, medialisation of the thyroid lobe, before release at Ligament of Berry, end of case) when analysed together with a Kruskal–Wallis test (H = 19.83, P < 0.001). However, Dunn’s post hoc multiple comparisons tests demonstrated that the vagus nerve mean EMG difference of mobilisation of the superior pole compared to baseline was not associated with a significant adjusted P value (M = 59.31 mA, P = 0.5449). Dunn’s post hoc multiple comparisons tests still demonstrated a highly significant mean difference in vagus nerve electromyography amplitude compared to baseline at medialisation of the thyroid lobe (M = 183.3 mA, P = 0.0017), before release at the Ligament of Berry (M = 201.3 mA, P < 0.001) and at end of procedure (M = 170.5 mA, P < 0.001 (Table 4).Table 4 Dunn’s multiple comparisons test Time points during surgery Mean difference 95% CI of difference P Baseline (V1) versus superior pole mobilised 59.31 (− 31.24, 149.9) 0.5449 Baseline (V1) versus medialisation 183.3 (43.30, 323.4) 0.0017 Baseline (V1) versus before release of RLN at Ligament of Berry 201.3 (57.09, 345.6) 0.0006 Baseline (V1) versus end of procedure (V2) 170.5 (47.02, 294.1) 0.0007 Factors predicting LOS When univariable logistic regression was performed, patient age, sex, BMI, preoperative ultrasound largest nodule, lobe volume, central lymph node dissection or indication for surgery were not significantly associated for LOS (Table 5).Table 5 Univariate logistic regression of patient variables for loss of signal Variables Univariate OR (95% CI) P Age (years) 0.95 (0.81, 1.11) 0.528 Sex 0.99 (0.87, 1.13) 0.579 BMI (kg/m2) 1.17 (0.83, 1.65) 0.374 Preoperative ultrasound largest nodule (mm)a 0.95 (0.82, 1.10) 0.525 Lobe volume (ml) 0.92 (0.67, 1.28) 0.640 Central lymph node dissection 0.95 (0.86, 1.20) 0.487 Indication for surgery Single/Multinodular goitre 2.54 (0.15, 31.3) 0.288 Malignancy 3.62 (0.20, 64.5) 0.381 Graves/Thyroiditis 7.25 (0.37, 140.0) 0.190 alog transformed Discussion Intraoperative nerve monitoring with EMG provides vital information regarding the neurophysiology of RLN function and provides insight into mechanisms of temporary nerve injury [11]. Despite the gold standard visual identification of the RLN during thyroid surgery, the actual cause of transient RLN palsy is not well understood [12]. Porcine studies have demonstrated that RLN mechanical traction, compression at defined pressures, and thermal injuries caused average decreases in signal amplitude between 40 and 60% by weakening RLN conduction velocity and stimulus quality [13]. Compression of the nerve causes neuropraxia and local myelin sheath deformation in animal models and also decreases nerve conduction amplitude [14, 15]. LOS is therefore observed in all three stress mechanisms of traction, compression and thermal injury [13]. This study suggests one mechanism for LOS during thyroidectomy is related to stretch injury or traction forces during thyroid mobilisation, between the stimulation points of vagus nerve and RLN. In this study, a key finding is that in the group without type 1 or type 2 LOS, there was a highly significant vagus nerve percentage amplitude drop at medialisation of the thyroid lobe (− 17.9 ± 53.1%, P < 0.001), before release at the Ligament of Berry (− 20.7 ± 61.7%, P < 0.001) and at the end of case (− 16.0 ± 47.2%, P < 0.001) compared to baseline. LOS was associated with a preceding 28.5% median amplitude drop and occurred exclusively during medialisation of the thyroid lobe. Stimulation of the RLN after clear anteromedial rotation of the thyroid lobe (R1) and at the conclusion of the case (R2) was not significantly different (P = 0.207). In our two cases with Type 1 LOS, no signal was present in V2 but an intact RLN signal present. This highlights the importance of testing V2 at the end of the procedure rather than relying on an intact RLN signal alone. It has been suggested that mechanisms that could result in LOS include excessive stretching of the distal RLN at the Ligament of Berry, which can cause injury to the fixed end of the nerve and its curve around the aortic arch and subclavian artery [12, 16]. Another postulated mechanism is traction on the extralaryngeal segment of the RLN during thyroid mobilisation, for example by pulling the RLN forward into an artificial genu above the inferior thyroid artery, out of the tracheoesophageal groove, which stresses the nerve [17]. Furthermore, RLN stretching from anteromedial rotation of the thyroid has been documented to increase nerve diameter, which is a possible mechanism for neuropraxia and hence, IONM amplitude reduction [18, 19]. Reductions in EMG amplitude suggest neurophysiological changes such as impaired propagation of action potentials along the nerve or diminished synaptic transmission [20]. Traction injury to the RLN is associated with histopathological morphology changes in the epineurium and perineurium of the nerve, including reductions in myelin thickness and axonal integrity [16, 21]. Amplitude decreases signify less nerve fibres participating in response to neural stimulation, and combined events of amplitude decreases and latency increases are strongly associated with LOS and RLN palsy [22]. In contrast, EMG amplitude in thyroidectomy often recovers when traction on the nerve is relieved [20, 23, 24]. Another distinctive finding in this study was that in type 2 LOS, all cases occurred after anteromedial rotation of the thyroid lobe. In the three cases with Type 2 LOS, there was no signal evident at testing of the RLN up until the point of insertion. This suggests that one potential mechanism of type 2 LOS is due to injury to the RLN within the intralaryngeal component of the larynx that cannot be tested, rather than due to anatomical variations (such as bifurcations of the RLN at the inferior thyroid artery, sympathetic fascial bands, a small anterior motor branch of a RLN bifurcating near the Ligament of Berry, compression between fascial leaflets at the Ligament of Berry or global stretch injury) [5, 25, 26]. Other studies have found that rotational forces through the larynx and trachea cause higher tracheal tube cuff pressures and consequently lower electromyography amplitudes, leading to diffuse type 2 LOS [27, 28]. In addition, we did not find any association on univariate regression analysis between patient variables of age, sex, BMI, largest nodule, preoperative ultrasound lobe volume, central lymph node dissection or indication for surgery as being predictive for loss of signal (Table 5). Longer operative duration and male sex have been associated with increased RLN palsy rates; however, intralaryngeal factors such as endotracheal tube size, intubation grade, Mallampati score and BMI did not increase RLN palsy rates or risk of focal nerve injury in a large retrospective study [29]. Female sex has also been found to be weakly associated with transient RLN palsy [30]. We reduced confounding by neuromuscular blockade by reversing all patients immediately after intubation. This is consistent with our finding of no significant difference in EMG amplitude between left and right baseline vagus stimulation (V1) in patients undergoing total thyroidectomy (P = 0.3942). However, limitations of the present study include potential positional changes of the endotracheal tube during the procedure. Rotational and depth changes of the endotracheal tube are documented to cause EMG amplitude changes [31–33]. We also attempted to reduce bias with a standardised surgical approach by a single surgeon, utilising the same nerve monitoring system, and minimising EMG confounding variables by using a single anaesthetist with placement of the tube under direct vision. Additionally, selection bias was reduced by selecting consecutive thyroidectomy cases. Further studies could include a clinical trial in electromyography comparing EMG amplitude changes in a retrograde RLN dissection, compared to the lateral approach utilised in the current study, which could potentially identify an alternative method in reducing traction forces on the RLN. Conclusion A significant decrease in vagus nerve EMG amplitude occurs during medialisation of the thyroid lobe in conventional thyroidectomy. Stretch injury or compression during thyroid mobilisation, most likely between the vagus and RLN stimulation sites, and within the intralaryngeal component of the RLN, is the most likely cause of RLN impairment during thyroidectomy. Acknowledgements The authors would like to acknowledge Professor Stan Sidhu for his ongoing feedback and constructive comments about the study, as well as all the clinical staff at the University of Sydney Endocrine Surgical Unit. Funding Open Access funding enabled and organized by CAUL and its Member Institutions. No funding or other support was received to carry out this work. Declarations Conflict of interest The authors declare that they have no conflict of interest. Ethical approval Ethical approval was obtained from the relevant Human Research Ethics Committee (2021/ETH11795). Informed consent Informed consent was obtained from all individual participants included in the study. Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. ==== Refs References 1. Chiang FY Lu IC Tsai CJ Does extensive dissection of recurrent laryngeal nerve during thyroid operation increase the risk of nerve injury? Evidence from the application of intraoperative neuromonitoring Am J Otolaryngol 2011 32 6 499 503 10.1016/j.amjoto.2010.11.001 21306792 2. Christou N Mathonnet M Complications after total thyroidectomy J Visc Surg 2013 150 4 249 256 10.1016/j.jviscsurg.2013.04.003 23746996 3. Calo PG Medas F Gordini L Interpretation of intraoperative recurrent laryngeal nerve monitoring signals: the importance of a correct standardization Int J Surg 2016 28 Suppl 1 S54 S58 10.1016/j.ijsu.2015.12.039 26708857 4. Anuwong A Lavazza M Kim HY Recurrent laryngeal nerve management in thyroid surgery: consequences of routine visualization, application of intermittent, standardized and continuous nerve monitoring Updates Surg 2016 68 4 331 341 10.1007/s13304-016-0393-9 27651334 5. Liddy W Wu CW Dionigi G Varied recurrent laryngeal nerve course is associated with increased risk of nerve dysfunction during thyroidectomy: results of the surgical anatomy of the recurrent laryngeal nerve in thyroid surgery study, an international multicenter prospective anatomic and electrophysiologic study of 1000 monitored nerves at risk from the international neural monitoring study group Thyroid 2021 31 11 1730 1740 10.1089/thy.2021.0155 34541890 6. Schneider R Randolph GW Dionigi G International neural monitoring study group guideline 2018 part I: staging bilateral thyroid surgery with monitoring loss of signal Laryngoscope 2018 128 Suppl 3 S1 S17 10.1002/lary.27359 30289983 7. Gur EO Haciyanli M Karaisli S Intraoperative nerve monitoring during thyroidectomy: evaluation of signal loss, prognostic value and surgical strategy Ann R Coll Surg Engl 2019 101 8 589 595 10.1308/rcsann.2019.0087 31219340 8. Francis DO Pearce EC Ni S Epidemiology of vocal fold paralyses after total thyroidectomy for well-differentiated thyroid cancer in a medicare population Otolaryngol Head Neck Surg 2014 150 4 548 557 10.1177/0194599814521381 24482349 9. Jeannon JP Orabi AA Bruch GA Diagnosis of recurrent laryngeal nerve palsy after thyroidectomy: a systematic review Int J Clin Pract 2009 63 4 624 629 10.1111/j.1742-1241.2008.01875.x 19335706 10. Yu Q Liu K Zhang S Application of continuous and intermittent intraoperative nerve monitoring in thyroid surgery J Surg Res 2019 243 325 331 10.1016/j.jss.2019.05.054 31255932 11. Genther DJ Kandil EH Noureldine SI Correlation of final evoked potential amplitudes on intraoperative electromyography of the recurrent laryngeal nerve with immediate postoperative vocal fold function after thyroid and parathyroid surgery JAMA Otolaryngol Head Neck Surg 2014 140 2 124 128 10.1001/jamaoto.2013.6139 24384927 12. Chiang FY Lu IC Kuo WR The mechanism of recurrent laryngeal nerve injury during thyroid surgery–the application of intraoperative neuromonitoring Surgery 2008 143 6 743 749 10.1016/j.surg.2008.02.006 18549890 13. Schneider R Przybyl J Pliquett U A new vagal anchor electrode for real-time monitoring of the recurrent laryngeal nerve Am J Surg 2010 199 4 507 514 10.1016/j.amjsurg.2009.04.036 20359570 14. Omura T Sano M Omura K A mild acute compression induces neurapraxia in rat sciatic nerve Int J Neurosci 2004 114 12 1561 1572 10.1080/00207450490509285 15512839 15. Schneider R Randolph G Dionigi G Prospective study of vocal fold function after loss of the neuromonitoring signal in thyroid surgery: the international neural monitoring study group’s POLT study Laryngoscope 2016 126 5 1260 1266 10.1002/lary.25807 26667156 16. Dionigi G Wu CW Kim HY Severity of recurrent laryngeal nerve injuries in thyroid surgery World J Surg 2016 40 6 1373 1381 10.1007/s00268-016-3415-3 26817650 17. Serpell JW New operative surgical concept of two fascial layers enveloping the recurrent laryngeal nerve Ann Surg Oncol 2010 17 6 1628 1636 10.1245/s10434-010-0928-0 20143268 18. Serpell JW Lee JC Yeung MJ Differential recurrent laryngeal nerve palsy rates after thyroidectomy Surgery 2014 156 5 1157 1166 10.1016/j.surg.2014.07.018 25444315 19. Serpell JW Lee JC Chiu WK Stressing the recurrent laryngeal nerve during thyroidectomy ANZ J Surg 2015 85 12 962 965 10.1111/ans.13054 25801287 20. Schneider R Bures C Lorenz K Evolution of nerve injury with unexpected EMG signal recovery in thyroid surgery using continuous intraoperative neuromonitoring World J Surg 2013 37 2 364 368 10.1007/s00268-012-1853-0 23188536 21. Byun SH Ahn KM Functional and electron-microscopic changes after differential traction injury in the sciatic nerve of a rat Maxillofac Plast Reconstr Surg 2021 43 1 12 10.1186/s40902-021-00297-4 33934285 22. Phelan E Schneider R Lorenz K Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: a prospective, multicenter study Laryngoscope 2014 124 6 1498 1505 10.1002/lary.24550 24307596 23. Schneider R Randolph GW Sekulla C Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury Head Neck 2013 35 11 1591 1598 10.1002/hed.23187 23169450 24. Chiang FY Lee KW Chen HC Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation World J Surg 2010 34 2 223 229 10.1007/s00268-009-0316-8 20020124 25. Snyder SK Lairmore TC Hendricks JC Elucidating mechanisms of recurrent laryngeal nerve injury during thyroidectomy and parathyroidectomy J Am Coll Surg 2008 206 1 123 130 10.1016/j.jamcollsurg.2007.07.017 18155577 26. Papachristos AJ Sidhu SB Thyroidectomy technique: defusing the recurrent laryngeal nerve - the superior approach Am J Surg 2021 222 4 712 714 10.1016/j.amjsurg.2021.03.039 33775410 27. Randolph GW Dralle H International Intraoperative Monitoring Study Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement Laryngoscope 2011 121 1 16 10.1002/lary.21119 28. Taylor JW Soeyland K Ball C Changes in tracheal tube cuff pressure and recurrent laryngeal nerve conductivity during thyroid surgery World J Surg 2020 44 2 328 333 10.1007/s00268-019-05185-7 31552459 29. Moreira A Forrest E Lee JC Investigation of recurrent laryngeal palsy rates for potential associations during thyroidectomy ANZ J Surg 2020 90 9 1733 1737 10.1111/ans.16166 32783252 30. Thomusch O Machens A Sekulla C Multivariate analysis of risk factors for postoperative complications in benign goiter surgery: prospective multicenter study in Germany World J Surg 2000 24 11 1335 1341 10.1007/s002680010221 11038203 31. Liu XL Wu CW Zhao YS Exclusive real-time monitoring during recurrent laryngeal nerve dissection in conventional monitored thyroidectomy Kaohsiung J Med Sci 2016 32 3 135 141 10.1016/j.kjms.2016.02.004 27106003 32. Tsai CJ Tseng KY Wang FY Electromyographic endotracheal tube placement during thyroid surgery in neuromonitoring of recurrent laryngeal nerve Kaohsiung J Med Sci 2011 27 3 96 101 10.1016/j.kjms.2010.08.002 21421197 33. Kim HY Tufano RP Randolph G Impact of positional changes in neural monitoring endotracheal tube on amplitude and latency of electromyographic response in monitored thyroid surgery: results from the porcine experiment Head Neck 2016 38 Suppl 1 E1004 E1008 10.1002/hed.24145 26040955